Configuring The Control Channel - Bosch LTC-1311-20 Configuration Manual

Video management system
Hide thumbs Also See for LTC-1311-20:
Table of Contents
Bosch Video Management System
Remote connection
Figure 25.2 Bosch Video Management System remote connection to a Bosch Allegiant matrix switch
1
2
3
4
5
6
7
25.2.2

Configuring the control channel

Perform the following tasks to configure the control channel:
Wiring
To configure the control channel between Bosch Video Management System and the Allegiant
matrix, connect one PC through an RS-232 serial port to the Allegiant's console port (use the
specified Bosch cable for connection). This can be the Bosch Video Management System
Central Server, or any other PC on the network.
Installing Allegiant Master Control Software
1.
2.
Bosch Sicherheitssysteme GmbH
Bosch Video Management System Client workstations
Central Server with Master Control Software
Network
Allegiant PC with Master Control Software
RS-232 connection
encoders
Allegiant matrix
Wiring
Installing the software
Creating Allegiant configuration file
Adding the Allegiant matrix to Bosch Video Management System
Configuring user names
Stop the Central Server service if running (Start > Control Panel > Services > Right-click
Bosch VMS Central Server > Stop)
Install the Allegiant Master Control Software on the Central Server and on the Allegiant PC