List Of Faults And Alarms; Faults - Siemens SINAMICS S120 Manual

Drive-based technology dcc addon description
Hide thumbs Also See for SINAMICS S120:
Table of Contents

4 List of Faults and Alarms

4
List of Faults and Alarms
4.1

Faults

F51050
Message value:
Message class:
Drive object:
Reaction:
Cause:
Remedy:
____________________________________________________________________________
F51051
Message value:
Message class:
Drive object:
Reaction:
Cause:
Remedy:
-
-
____________________________________________________________________________
F51052
Message value:
Message class:
Drive object:
Reaction:
Cause:
Remedy:
-
-
____________________________________________________________________________
F51053
Message value:
Message class:
Drive object:
Reaction:
Cause:
Remedy:
Extended Crane Drive-Based Technology AC
Extended Crane Drive-Based Technology SINAMICS S120
DCC Add-On Description 109767457,
MasterSwitch_Masterswitch selection fault
-
Application/technological function faulted
All objects
PULSE INHIBIT
Multiple master switches from the MasterSwitchMux are enabled
simultaneously, e.g. digital master switch and analog master switch.
Enable only one of the options from the MasterSwitchMux
BrakeTest_Brake test failed
-
Application/technological function faulted
All objects
PULSE INHIBIT
The actual speed exceeded the value set in p22030
(BrakeTest_BrakeTestSpeedThreshold (%)) over the time set in p22032
(BrakeTest_BrakeTestFail_DelayTime (ms)).
Possible remedies are:
Verify via trace is actual torque reached the desired brake holding
torque, if brake holding torque reached and motor slips through brakes,
then perform preventative maintenance on brakes.
If brakes are functioning properly, ensure that brakes are properly
sized.
MonitoringTP_H1_Torque proving failure (H1)
-
Application/technological function faulted
All objects
PULSE INHIBIT
The actual torque for hoist 1 did not reach the torque to be proven
(either actual torque at previous braking or minimum torque value) over
the time set in p22167.
Possible remedies are:
If using a minimum value ensure that minimum value is set properly and
is realistic. Increase the torque building speed setpoint limit or decrease
the torque building time.
If desired torque to be proven is still not reached, increase the torque
building speed setpoint limit and decrease the torque building time.
MonitoringTP_H2_Torque proving failure (H2)
-
Application/technological function faulted
All objects
PULSE INHIBIT
The actual torque for hoist 2 did not reach the torque to be proven
(either actual torque at previous braking or minimum torque value) over
the time set in p22287.
Possible remedies are:
V1.2,
09/2019
47