Heating Capacity - Fujitsu General ARXG36KHTAP Design & Technical Manual

Duct type
Hide thumbs Also See for General ARXG36KHTAP:
Table of Contents

4-2. Heating capacity

NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢ Model: ARXG36KHTAP
AFR
°CDB
°CWB
-15
-16
-10
-11
-5
-7
0
-2
5
3
7
6
10
8
15
10
20
15
24
18
¢ Model: ARXG45KHTAP
AFR
°CDB
°CWB
-15
-16
-10
-11
-5
-7
0
-2
5
3
7
6
10
8
15
10
20
15
24
18
¢ Model: ARXG54KHTAP
AFR
°CDB
°CWB
-15
-16
-10
-11
-5
-7
0
-2
5
3
7
6
10
8
15
10
20
15
24
18
4-2. Heating capacity
3
m
/h
16
18
TC
IP
TC
kW
kW
8.05
2.91
8.01
9.21
3.14
9.17
10.37
3.38
10.32
11.01
3.63
10.97
12.30
3.69
12.24
12.81
3.71
12.75
13.20
3.71
13.15
13.73
3.71
13.68
14.63
3.72
14.56
15.34
3.73
15.27
3
m
/h
16
18
TC
IP
TC
kW
kW
12.04
4.31
11.75
13.37
4.49
13.05
14.70
4.68
14.35
15.48
4.86
15.11
16.57
4.30
16.18
17.01
4.30
16.61
17.72
4.29
17.29
18.89
4.27
18.44
20.07
4.25
19.59
21.01
4.24
20.50
3
m
/h
16
18
TC
IP
TC
kW
kW
12.26
4.49
11.97
13.62
4.68
13.29
14.97
4.87
14.61
15.77
5.06
15.39
16.88
4.59
16.48
17.33
4.58
16.91
18.05
4.57
17.61
19.24
4.56
18.78
20.44
4.54
19.95
21.40
4.53
20.88
Indoor temperature
20
IP
TC
IP
kW
2.91
7.98
2.91
3.14
9.13
3.15
3.38
10.28
3.38
3.64
10.92
3.64
3.69
12.19
3.70
3.72
12.70
3.72
3.72
13.09
3.72
3.72
13.62
3.72
3.73
14.50
3.73
3.73
15.21
3.74
Indoor temperature
20
IP
TC
IP
kW
4.33
11.46
4.35
4.52
12.73
4.54
4.70
14.00
4.72
4.88
14.74
4.91
4.32
15.78
4.35
4.32
16.20
4.34
4.31
16.87
4.33
4.29
17.99
4.31
4.28
19.11
4.30
4.26
20.00
4.29
Indoor temperature
20
IP
TC
IP
kW
4.51
11.67
4.53
4.70
12.97
4.72
4.89
14.26
4.92
5.08
15.02
5.11
4.61
16.08
4.64
4.61
16.50
4.63
4.60
17.18
4.62
4.58
18.32
4.60
4.56
19.46
4.59
4.55
20.37
4.57
- 9 -
1,850
22
24
TC
IP
TC
kW
kW
7.77
2.92
7.26
8.89
3.15
8.31
10.02
3.39
9.35
10.64
3.65
9.94
11.88
3.70
11.09
12.37
3.72
11.56
12.75
3.72
11.91
13.27
3.72
12.39
14.13
3.73
13.19
14.82
3.74
13.84
2,550
22
24
TC
IP
TC
kW
kW
11.19
4.35
10.53
12.43
4.54
11.69
13.67
4.72
12.86
14.40
4.91
13.54
15.42
4.35
14.50
15.82
4.34
14.88
16.48
4.33
15.50
17.57
4.31
16.53
18.66
4.30
17.55
19.54
4.29
18.38
2,550
22
24
TC
IP
TC
kW
kW
11.40
4.58
10.72
12.66
4.78
11.91
13.93
4.97
13.10
14.67
5.17
13.79
15.70
4.69
14.77
16.12
4.68
15.16
16.78
4.67
15.79
17.90
4.65
16.83
19.01
4.64
17.88
19.90
4.62
18.72
4. Capacity table
IP
2.93
3.16
3.40
3.66
3.71
3.74
3.74
3.74
3.75
3.75
IP
4.35
4.54
4.72
4.91
4.35
4.34
4.33
4.31
4.30
4.29
IP
4.71
4.91
5.11
5.31
4.82
4.81
4.80
4.78
4.76
4.75
Table of Contents
loading