Fujitsu ASYG07KMTB Operating Manual
Hide thumbs Also See for ASYG07KMTB:

Quick Links

OPERATING MANUAL
MODEL:
* Please write down the model name.
(Refer to the rating label.)
* Bitte schreiben Sie den Modellnamen auf.
(Siehe Typenschild)
* Veuillez écrire le nom du modèle.
(Consultez l'étiquette des spécifications.)
* Anote el nombre de modelo.
(Consulte la etiqueta de calificación).
* Annotare il nome del modello.
(Fare riferimento all'etichetta delle specifiche).
* Καταγράψτε το όνομα μοντέλου.
(Ανατρέξτε στην ετικέτα τεχνικών στοιχείων.)
* Registe o nome de modelo.
(Consulte a etiqueta de classificação.)
* Запишите название модели.
(См. на паспортной табличке.)
* Lütfen model adını not ediniz.
(Derece etiketine bakınız.)
PART No. 9387858020
AIR CONDITIONER (Wall Mounted type)
Before using this product, read these instructions thoroughly
and keep this manual for future reference.
BEDIENUNGSANLEITUNG
KLIMAANLAGE (Wandmontierter Typ)
Bevor Sie dieses Produkt verwenden, lesen Sie diese
Anweisungen sorgfältig durch und bewahren Sie diese
Anleitung für späteres Nachschlagen auf.
CLIMATISEUR (Type à montage mural)
Avant d'utiliser ce produit, veuillez lire attentivement ces
instructions. Conservez ce manuel pour référence future.
MANUAL DE FUNCIONAMIENTO
ACONDICIONADOR DE AIRE (Tipo montado en pared)
Antes de utilizar el producto, lea estas instrucciones detenida-
mente y conserve este manual para consultarlo en el futuro.
CONDIZIONATORE D'ARIA (Tipo montato a parete)
Prima di utilizzare l'apparecchio, leggere attentamente
le presenti istruzioni e conservare il manuale per poterlo
ΚΛΙΜΑΤΙΣΤΙΚΟ (Επιτοίχιος τύπος)
Προτού χρησιμοποιήσετε το προϊόν, διαβάστε προσεκτικά τις
παρούσες οδηγίες και φυλάξτε το παρόν εγχειρίδιο, ώστε να
μπορείτε να ανατρέχετε σε αυτό στο μέλλον.
MANUAL DE FUNCIONAMENTO
AR CONDICIONADO (Tipo mural)
Antes de utilizar este produto, leia atentamente estas instruções
e guarde este manual para referência futura.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
КОНДИЦИОНЕР ВОЗДУХА (Настенного типа)
Перед эксплуатацией устройства внимательно
ознакомьтесь с данным руководством и сохраняйте его для
Bu ürünü kullanmadan önce verilen talimatları dikkatlice okuyun
ve daha sonra tekrar faydalanmak üzere saklayın.
OPERATING MANUAL
MODE D'EMPLOI
MANUALE DI ISTRUZIONI
consultare il futuro.
ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
использования в будущем.
KULLANIM KILAVUZU
KLİMA (Duvara Monte tip)
Table of Contents
loading

Summary of Contents for Fujitsu ASYG07KMTB

  • Page 1 OPERATING MANUAL OPERATING MANUAL AIR CONDITIONER (Wall Mounted type) Before using this product, read these instructions thoroughly and keep this manual for future reference. BEDIENUNGSANLEITUNG KLIMAANLAGE (Wandmontierter Typ) Bevor Sie dieses Produkt verwenden, lesen Sie diese Anweisungen sorgfältig durch und bewahren Sie diese Anleitung für späteres Nachschlagen auf.
  • Page 2: Table Of Contents

    [Original Instructions] Contents CAUTION This symbol shows that the operating manual should 1. SAFETY PRECAUTIONS .......... 1 be read carefully. CAUTION 2. PREPARATION ............2 This symbol shows that a service personnel should 3. NAME OF PARTS ............. 3 be handling this equipment with reference to the 3.1.
  • Page 3: Preparation

    WARNING CAUTION • Do not touch the aluminum fins of heat exchanger • This product is not intended for use by persons (including children) with reduced physical, sensory built-in this product to avoid personal injury when you or mental capabilities, or lack of experience and maintain the unit.
  • Page 4: Name Of Parts

    Battery loading and remote controller preparation Color Operation or condition Name (R03/LR03/AAA x 2) Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 °C Heat operation Put batteries as shown in the figure above. 3.2. Remote controller Press to start clock setting.
  • Page 5 CAUTION • To prevent malfunction or damage of the remote controller: - Place remote controller at where will not be exposed to direct sunlight or excessive heat. - Remove batteries if the product is not going to be used for an extended period. •...
  • Page 6: Basic Operations

    ■ Airflow direction range 4. BASIC OPERATIONS Vertical airflow direction ■ 3 steps to start operation 1 ⇄ 2 ⇄ 3 ⇄ 4 ⇄ 5 ⇄ 6 Change by 1. Press to start or stop the operation. Swing operation by 2.
  • Page 7: Sleep Timer

    6.3. Sleep timer 8. OTHER OPERATIONS The Sleep timer supports your comfortable sleep by moderating the air conditioner operation gradually. 8.1. Powerful operation 1. Press In the Powerful operation, the air conditioner will operate at maximum 2. Press to set the time until the operation power and strong airflow to cool down or warm up the room quickly.
  • Page 8: Settings On Installation

    The frequency of the cleaning is as shown in the following table. 9. SETTINGS ON INSTALLATION What to do Frequency Cleaning indoor unit body When you notice 9.1. Remote controller custom code setting Cleaning air filter Every 2 weeks Cleaning Ion deodorization filter Every 3 months By setting custom code of indoor unit and remote controller, you can Replacing Apple-catechin filter...
  • Page 9 Cleaning Ion deodorization filter and Removing and installing intake grille Replacing Apple-catechin filter ■ Removing intake grille 1. Remove the air filters. Refer to steps 1 ~ 2 of “Cleaning air 1. Open the intake grille until it snaps. filter”. 2.
  • Page 10: General Information

    11. GENERAL INFORMATION 12. OPTIONAL PARTS ■ Heating performance 12.1. Wired remote controller This air conditioner operates on the heat-pump principle, absorbing heat from air outdoors and transferring that heat to the indoor unit. As a The optional wired remote controller can be used. result, the operating performance is reduced as outdoor air temperature drops.
  • Page 11: Troubleshooting

    ● Operation can be done in the following different operating modes. Airflow is weak or stops. Cooling mode and Dry mode □ Is the fan speed set to Quiet? ⇒ To change the fan speed, refer to page 5. Cooling mode and Fan mode □...
  • Page 12 ■ State of indicator lamps Lighting pattern: Off, Blinking, Any state State Causes and solutions page Automatic defrosting operation ⇒ Please wait until finishing the defrosting (maximum of 15 minutes). Filter indicator ⇒ Clean the air filter and reset the filter sign.

This manual is also suitable for:

Asyg14kmtb

Table of Contents