Installation Location; Room Temperature And Ventilation - Siemens KGF Series User Manual

Fridge-freezer combination
Hide thumbs Also See for KGF Series:
Table of Contents

Installation location

A dry, well ventilated room is suitable as
an installation location. The installation
location should not be exposed to direct
sunlight and not placed near a heat
source, e.g. a cooker, radiator, etc. If
installation near a heat source is
unavoidable, use a suitable insulating
plate or observe the following minimum
distances to a heat source:
3 cm to electric or gas cookers.
30 cm to oil or coal-fired cookers.
The floor at the installation location must
not sag. If necessary, reinforce floor. If
necessary, compensate for floor
unevenness with underlays.
Distance from the wall
When installing the appliance, ensure a
door opening angle of 90°.
Room temperature and
ventilation
Room temperature
The appliance is designed for a certain
climate class. Depending on the climate
class, the appliance can be operated at
the following room temperatures.
The climate class can be found
on the rating plate. Fig.
Climate class
SN
N
ST
T
Note
The appliance is fully functional within the
room temperature limits of the indicated
climate class. If an appliance of climatic
class SN is operated at colder room
temperatures, the appliance will not be
damaged up to a temperature of +5°C.
Ventilation
Fig. 2
The air at the back panel and the side
panels of the appliance heats up.
Dissipation of the heated air must not be
obstructed. Otherwise, the refrigeration
unit must work harder. This increases
power consumption. Therefore: never
cover or block ventilation openings!
.
Permitted room
temperature
+10°C to 32°C
+16°C to 32°C
+16°C to 38°C
+16°C to 43°C
en
7
Table of Contents
loading

Table of Contents