Panasonic S-80MW1E5 Operating Instructions Manual

Panasonic S-80MW1E5 Operating Instructions Manual

Air-to-water heatpump

Quick Links

Model No.
INDOOR UNIT
Air-to-Water Heatpump
(Type W1)
S-80MW1E5
S-125MW1E5
● Connectable outdoor unit lineup
This booklet is the operating
instructions for indoor unit. Regarding
the outdoor unit, see the operating
instructions supplied with the outdoor
unit.
OUTDOOR UNIT
3WAY VRF (Type MF2)
OI_00_271368_Eng.indb 1
ENGLISH
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
FRANÇAIS
Avant d'utiliser l'appareil, lisez ce mode d'emploi dans son intégralité et
conservez-le pour toute référence ultérieure.
ESPAÑOL
Antes de operar la unidad, lea atentamente estas instrucciones de
funcionamiento y guárdelas para futuras consultas.
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese
Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die
künftige Verwendung auf.
ITALIANO
Prima di utilizzare l'unità, leggere a fondo queste istruzioni per l'uso e
conservarle come riferimento futuro.
NEDERLANDS
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en
bewaar ze voor toekomstig gebruik.
PORTUGUÊS
Antes de utilizar o aparelho, leia completamente este manual de instruções
e guarde-o para futuras referências.
EΛΛΗΝΙΚΆ
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες
χρήσης και διατηρήστε τις για μελλοντική αναφορά.
БЪЛГАРСКИ
Преди да започнете експлоатация на този уред, прочетете внимателно
тези инструкции и ги запазете, за да можете да правите справки с тях и
в бъдеще.
TÜRKÇE
Üniteyi çalıştırmadan önce bu çalıştırma talimatlarını iyice okuyun ve
gelecekte başvurmak için saklayın.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
Operating Instructions
Air-to-Water Heatpump
2 ~ 13
14 ~ 25
26 ~ 37
38 ~ 49
50 ~ 61
62 ~ 73
74~ 85
86 ~ 97
98 ~ 109
110 ~ 121
E
NGLISH
F
RANÇAIS
E
SPAÑOL
D
EUTSCH
I
TALIANO
N
EDERLANDS
P
ORTUGUÊS
E
ΛΛΗΝΙΚΆ
Б
ЪЛГАРСКИ
T
ÜRKÇE
F570002
2015-7-2 9:14:16
Table of Contents
loading

Summary of Contents for Panasonic S-80MW1E5

  • Page 1 EUTSCH Air-to-Water Heatpump künftige Verwendung auf. (Type W1) ITALIANO 50 ~ 61 Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e S-80MW1E5 TALIANO conservarle come riferimento futuro. S-125MW1E5 ● Connectable outdoor unit lineup NEDERLANDS 62 ~ 73...
  • Page 2: Table Of Contents

    Thank you for purchasing this Panasonic product. WARNING This product is a commercial Air-to-Water unit. Installation Instructions attached. Be sure to read the operating instructions relevant to the Confirm to authorized dealer VRF system connected to this Air-to-Water and all appliances or specialist on usage of connected to the VRF system.
  • Page 3 CAUTION This appliance is intended to be used Provide a power outlet to be used by expert or trained users in shops, exclusively for each unit, and a in light industry and on farms, or for power supply disconnect, Earth commercial use by lay persons.
  • Page 4: Precautions For Use

    Precautions for Use Installation Operation Condition This Air-to-Water must be installed properly by qualified Use this Air-to-Water under the following temperature range. installation technicians in accordance with the Installation Indoor (water) Outdoor Instructions provided with the unit. Outdoor Unit temperature temperature Before installation, check that the voltage of the electric range...
  • Page 5: Names Of Parts

    Names of Parts INDOOR UNIT NGLISH Water drain Water outlet Water inlet High-spec Wired Remote Controller (Optional: Model No. CZ-RTC5) Return button Menu button Returns to the previous screen. Displays the menu screen LCD screen Cross key buttons Selects an item. HOT-WATER-SUPPLY 20:30 (THU) SET TEMP.
  • Page 6 Names of Parts TANK mode „ Setting information icons displayed on the top screen Icon Description Switching operation modes is prohibited. (Switching to Auto mode is also prohibited.) Remote control operation is restricted by a central control device. [ON/OFF timer] is set. [Weekly timer] is set.
  • Page 7: Initial Settings

    Initial Settings „ Clock „ Clock type „ Operation lock When applying a power on for the first time, it is necessary to initialize the remote controller for Air-to-Water unit. Please refer to the installation instructions or consult the contractor. 1 Display the menu screen.
  • Page 8: Operation

    Operation TANK mode 1 Start Operation Press HOT-WATER-SUPPLY 20:30 (THU) (The operation indicator illuminates.) SET TEMP. Water Temperature TANK ℃  To change the setting  To stop 2 Change the temperature setting (The operation indicator turns off) Press (In TANK mode, only “SET TEMP.” can be changed. : 35°C to 65°C) (The cursor disappears.) Operation indicator Air-Conditioning mode...
  • Page 9: Operation Mechanism

    Operation mode (e.g. Cool, Heat) AIR-CONDITIONING 20:30 (THU) AIR-CONDITIONING 20:30 (THU) Press SET TEMP. MODE SET TEMP. MODE HEAT COOL Cool Heat ℃ ℃ Set temperature Press (When the cursor is not visible.) Water temperature AIR-CONDITIONING 20:30 (THU) Cool : 5°C to 20°C SET TEMP.
  • Page 10: Function Of Air-To-Water Unit

    Function of Air-to-Water Unit 1 Display the menu screen.  TANK mode 3 Select the item 20:30 (THU) Menu 20:30 (THU) Air-to-Water unit 20:30 (THU) 1. Basic instructions to set. 2. FLAP Sterilization timer 3. Lock indiv. flap 4. ON/OFF timer Stop sterilization START Sel.
  • Page 11 „ Int. heater forced ON The internal heater of Air-to-Water unit can be turned ON manually. When the internal heater is turned ON manually, icon appears. * This feature is for emergency operation when the outdoor unit has trouble. Air-to-Water unit 20:30 (THU) Contact to service technician definitely before setting this function.
  • Page 12: Maintenance

    Maintenance Do not attempt to clean inside the unit by yourself. Refer to the section “Care and Cleaning” in the Installation Instructions. WARNING CAUTION For safety, be sure to turn the Air-to-Water off and Never use solvents or harsh chemicals. Also, do not wipe disconnect the power before cleaning.
  • Page 13: Troubleshooting

    Troubleshooting Check before consulting or requesting services. Symptom Cause / Action • Sound of water flowing inside unit Sound like streaming water is heard • Sound of refrigerant liquid flowing inside unit during operation or after operation. • Sound of drainage water through drain pipe Noise Cracking noise is heard during operation Sound due to temperature changes of parts...
  • Page 14 Specifications Indoor unit Air-to-Water Heatpump (Type W1) Model Name S-80MW1E5 S-125MW1E5 220 / 230 / 240 V ~ 50Hz Power Source 12.5 Cooling capacity BTU/h 27,000 42,700 14.0 Heating capacity BTU/h 30,000 47,800 Sound Pressure dB(A) level Sound Power level...
  • Page 15 Specifications Corresponding language table English Français Español Deutsch Air-to-Water Heatpump Conduit Mince Faible Statique Conductos finos de presión Flaches Kanalgerät mit (Type W1) (Type W1) estática baja (tipo W1) niedriger statischer Pressung (Typ W1) 3WAY (Type MF2) 3WAY (Type MF2) 3WAY (tipo MF2) 3WAY (Typ MF2) English...
  • Page 16 Corresponding language table English Français Español Deutsch Model Name Nom du modèle Nombre del modelo Modellbezeichnung Power Source Source d'alimentation Fuente de alimentación Spannungsquelle Cooling Capacity Capacité de refroidissement Capacidad de refrigeración Kühlleistung Heating Capacity Capacité de chauffage Capacidad de calefacción Heizleistung Sound Pressure Level Niveau de pression sonore...
  • Page 17 MEMO OI_00_271368_Eng.indb 125 2015-7-2 9:14:30...
  • Page 18 MEMO OI_00_271368_Eng.indb 126 2015-7-2 9:14:30...
  • Page 19 MEMO OI_00_271368_Eng.indb 127 2015-7-2 9:14:30...
  • Page 20 Panasonic Corporation Authorised representative in EU Website: http://www.panasonic.com Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg, Germany © Panasonic Corporation 2015 F570002 Printed in Malaysia BE0715-0 OI_00_271368_Eng.indb 128 2015-7-2 9:14:30...

This manual is also suitable for:

S-125mw1e5

Table of Contents