Dip Switch Setting - Mitsubishi Electric PAC-IF071B-E Installation Manual

Flow temp. controller [main/sub] (cased)
Table of Contents

5. Dip Switch setting

5.1 DIP Switch Functions
Located on the FTC printed circuit board are 6 sets of small white switches known
as DIP switches. The DIP switch number is printed on the circuit board next to
the relevant switches. The word ON is printed on the circuit board and on the DIP
switch block itself. To move the switch you will need to use a pin or the corner of
a thin metal ruler or similar.
DIP switch settings are listed below in Table 5.1.1.
Only an authorised installer can change DIP switch setting under one's own re-
sponsibility according to the installation condition.
Make sure to turn off both indoor unit and outdoor unit power supplies before
changing the switch settings.
For multiple outdoor units control with FTC (sub), see section 9.3.2.
DIP switch
SW1 SW1-1 Boiler
SW1-2 Heat pump maximum outlet water temperature 55ºC
SW1-3 DHW tank
SW1-4 Immersion heater
SW1-5 Booster heater
SW1-6 Booster heater function
SW1-7 Outdoor unit type
SW1-8 Wireless remote controller
SW2 SW2-1 Room thermostat1 input (IN1) logic change Zone1 operation stop at thermostat short Zone1 operation stop at thermostat open OFF
SW2-2 Flow switch1 input (IN2) logic change
SW2-3 Booster heater capacity restriction
SW2-4 Cooling mode function
Automatic switch to backup heat source op-
SW2-5
eration (When outdoor unit stops by error)
SW2-6 Mixing tank
SW2-7 2-zone temperature control
SW2-8 Flow sensor
SW3 SW3-1 Room thermostat 2 input (IN6) logic change Zone2 operation stop at thermostat short Zone2 operation stop at thermostat open OFF
SW3-2 Flow switch 2 and 3 input logic change
SW3-3
SW3-4 Electric energy meter
SW3-5 Heating mode function *3
SW3-6 2-zone valve ON/OFF control
SW3-7 Heat exchanger for DHW
SW3-8 Heat meter
SW4 SW4-1 Multiple outdoor unit control
SW4-2 Position of multiple outdoor unit control *7
SW4-3
SW4-4 Indoor unit only operation (during installation work) *4 Inactive
SW4-5 Emergency mode (Heater only operation)
SW4-6 Emergency mode (Boiler operation)
SW5 SW5-1
SW5-2 Advanced auto adaptation
SW5-3
SW5-4
SW5-5
SW5-6
SW5-7
SW5-8
SW6
SW6-1
SW6-2
SW6-3 Pressure sensor
en
SW6-4 Analog output signal (0-10V)
SW6-5
Note:
*1. When the FTC unit is connected with a outdoor unit of which maximum outlet water temperature is 55ºC, DIP SW1-2 must be changed to OFF.
*2. External output (OUT11) will be available. For safety reasons, this function is not available for certain errors. (In that case, system operation must
be stopped and only the water circulation pump keeps running.)
*3. This switch functions only when the cylinder unit is connected with a PUHZ-FRP outdoor unit. When another type of outdoor unit is connected,
the heating mode function is active regardless of the fact that this switch is ON or OFF.
*4. Space heating and DHW can be operated only in indoor unit, like an electric heater. (Refer to "5.7 Indoor unit only operation". )
*5. If emergency mode is no longer required, return the switch to OFF position.
*6. Active only when SW3-6 is set to OFF.
*7. SW4-2 is available only when SW4-1 is ON.
25
Function
WITHOUT Boiler
WITHOUT DHW tank
WITHOUT Immersion heater
WITHOUT Booster heater
For heating only
Split type
WITHOUT Wireless remote controller WITH Wireless remote controller
Failure detection at short
Inactive
Inactive
Inactive
WITHOUT Mixing tank
Inactive
WITHOUT Flow sensor
Failure detection at short
WITHOUT Electric energy meter
Inactive
Inactive
Coil in tank
WITHOUT Heat meter
Inactive
Sub
Normal
Normal
Inactive
Inactive
Inactive
OFF
WITH Boiler
60ºC
WITH DHW tank
WITH Immersion heater
WITH Booster heater
For heating and DHW
Packaged type
Failure detection at open
Active
Active
Active *2
WITH Mixing tank
Active *6
WITH Flow sensor
Failure detection at open
WITH Electric energy meter
Active
Active
External plate HEX
WITH Heat meter
Active
Main
Active
Emergency mode (Heater only operation) OFF *5
Emergency mode (Boiler operation) OFF *5
Active
Active
Active
Default settings:
ON
Indoor unit model
OFF
ON *1
OFF: PAC-IF071B-E
ON : PAC-IF072/073B-E
OFF: PAC-IF071B-E
ON : PAC-IF072/073B-E
OFF
OFF
OFF: PAC-IF071B-E
ON : PAC-IF072/073B-E
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF: PAC-IF071/072B-E
ON: PAC-IF073B-E
OFF
OFF
OFF
OFF
SW5
SW4
SW3
SW2
SW1
SW6
Table of Contents
loading

This manual is also suitable for:

Pac-if072b-ePac-if073b-ePac-sif051b-e

Table of Contents