Kaba PowerLever PROX 9000 Series Quick Reference Manual
Kaba PowerLever PROX 9000 Series Quick Reference Manual

Kaba PowerLever PROX 9000 Series Quick Reference Manual

Hide thumbs Also See for PowerLever PROX 9000 Series:

Quick Links

Quick Reference Guide
®
P
L
PROX
OWER
EVER
9 0 0 0
Series
Table of Contents
loading

Summary of Contents for Kaba PowerLever PROX 9000 Series

  • Page 1 Quick Reference Guide ® PROX OWER EVER 9 0 0 0 Series...
  • Page 2 Notice: The information in this manual is subject to change without notice and does not represent a commitment on the part of Kaba Mas. Kaba Mas shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance or use of this material.
  • Page 3: Table Of Contents

    ABLE OF ONTENTS ..................... 1 NTRODUCTION System Components ..................1 Lock Modes ....................1 Lock Entry Methods ..................2 Lock Operation ....................2 Operating Conventions ................... 2 Lock Responses .................... 3 ................4 EYPAD OMMANDS ................ 5 ACTORY PERATIONS Door Access ....................5 Open Door with Default Factory Master User PIN ........
  • Page 5: Introduction

    NTRODUCTION This guide provides a quick summary of information necessary for the operation of the PowerLever PROX 9000 Series system. Prior to using the Quick Reference Guide, you should have completed all activities outlined in the Getting Started Guide. The Quick Reference Guide is intended to cover the basic operational functions of the lock at the keypad.
  • Page 6: Lock Entry Methods

    Lock Entry Methods A lock can be opened using one of three different access methods: PIN & PROX Card PROX Card Only PIN Only Lock Operation The PowerLever lock is designed to operate using internally-generated power. The self-contained PowerStar generator is triggered by depressing the outside lever. One simultaneous flash of the green and red LEDs accompanied by a low volume beep indicates that the lock is powered.
  • Page 7: Lock Responses

    Lock Responses The tables below summarize how the red and green LEDs are flashed individually, simultaneously, or in combination to indicate various conditions. Each LED flash is accompanied by a beep for audio reinforcement. Flashes Green LED Red LED Continuous Present Card Low Power Keystroke Entry Input Accepted/DST Activated...
  • Page 8: Lock Keypad Commands

    EYPAD OMMANDS The following is a list of the keypad commands that are available for the PowerLever PROX 9000 Series locks. Command: Description: Factory Mode Commands and then 000 Change Default Factory Master User PIN (p. 5) Activated Mode Commands and then 001 Set Lock Date (p.
  • Page 9: Factory Mode Operations

    ACTORY PERATIONS The following lock operations can only be performed while the lock is in Factory Mode. Door Access Open Door with Default Factory Master User PIN Power lock. Enter Default Factory Master User PIN of “12345678”. Depress outside lever to open lock. System Maintenance at Lock Change Default Factory Master User PIN Power lock.
  • Page 10: Activated Mode Operations (Using Software )

    CTIVATED PERATIONS SING OFTWARE The following operations can be performed while the lock is in Activated Mode with software. Door Access Open Door with PIN & PROX Card Power lock. Enter PIN. Present PROX Card. Depress outside lever to open lock. Open Door with PROX Card Only Power lock.
  • Page 11: Set Lock's Relock Time

    Set Lock’s Relock Time Power lock. If PIN is required, enter Master User PIN or a Manager User PIN. If PROX Card is required, present PROX Card. Press followed by 004. Enter two-digit relock time (02-10 seconds). Set Tamper Shutdown Time Power lock.
  • Page 12: Enable Access User

    Enable Access User Power lock. If PIN is required, enter Master User PIN or a Manager User PIN. If PROX Card is required, present PROX Card. Press followed by 300. Enter PIN of Access User to be enabled. Enable Manager User Power lock.
  • Page 13: Disable Access User

    Disable Access User Power lock. If PIN is required, enter Master User PIN or a Manager User PIN. If PROX Card is required, present PROX Card. Press followed by 400. Enter PIN of Access User to be disabled. Disable Manager User Power lock.
  • Page 14: Reset Lock Settings To Factory Defaults

    Reset Lock Settings to Factory Defaults Power lock. If PIN is required, enter Master User PIN. If PROX is required, present PROX Card. Press followed by 800. The lock settings are returned to the default Factory Mode settings. No users are deleted and the lock retains the current Master User PIN and PROX (if applicable).
  • Page 15: Reset Lock Settings To Factory Mode (Hard Reset)

    Reset Lock to Factory Mode (Hard Reset) Remove the lock back cover. Press and hold the small “Reset Switch” (SW2) on the bottom right hand corner of the lock controller board with a non-metal tool. Depress the outside lever as you would to power the lock. Repeat this action until you get two green flashes accompanied by beeps.
  • Page 17 OTES...
  • Page 20 Document Number 486.093 Rev. A - 04/04 Kaba Access Control 2941 Indiana Avenue Winston-Salem, NC 27105 USA Tel: (800) 849-8324 (336) 725-1331 FAX: (800) 346-9640 (336) 725-3269 Technical Support: (800) 950-4744 www.kaba-ilco.com www.powerleverprox.com...

Table of Contents