Removal Of Hygroscopic Fan Rotor / Hygroscopic Fan Motor - Daikin 2MXU40GV1B Service Manual Removal Procedure

Hide thumbs Also See for 2MXU40GV1B:
Table of Contents

Removal of Hygroscopic Fan Rotor / Hygroscopic Fan Motor

6. Removal of Hygroscopic Fan Rotor / Hygroscopic
Fan Motor
Procedure
Step
1. Removal of the
hygroscopic fan rotor
ASSY
1
Disconnect the
connector for fan motor
and remove the bell
mouth on adsorption
side.
Unscrew the fan fixing
2
nut (M6) of the
hygroscopic fan rotor
ASSY (sirocco fan rotor
ASSY) and remove.
2. Removal of the
hygroscopic fan motor
1
Remove the 3 screws
of the motor cover.
Remove the
2
hygroscopic fan motor.
16
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Fan fixing
nut
Hygroscopic
fan motor
Preparation
Remove the humidifying
rotor according to "Removal
of Humidifying Rotor".
(R9928)
When reassembling, align
the
motor shaft.
Hygroscopic
Wrench size: 10mm
fan rotor
ASSY
(R5821)
Lift the motor cover first and
pull out.
(R5822)
Motor cover
(R5823)
Si121091
Points
mark and D cut of the
(R5824)
Removal Procedure