Honeywell homexpert Rondostat COMFORT+ HR30 Manual

Honeywell homexpert Rondostat COMFORT+ HR30 Manual

Electronic radiator controller
HR30
Electronic
Radiator controller
1. Scope of delivery
The radiator controller packaging contains:
1
1 Radiator controller, without batteries
2 Valve baseplate M30 x 1.5
3 Display element
4 Bag with adapters (Danfoss RA, RAV, RAVL)
Danger of suffocation!
f Keep packaging materials away from
children.
WaRnIng
2
3
4
2. Brief description
With the electronic radiator controller you can set your
room temperature exactly to your requirements while
additionally saving energy.
i
Lowering the room temperature by 1 °C saves
approx. 6% energy!
User-friendly
• Large adjustable display with backlight.
• Convenient programming through removal of the
radiator controller from the valve.
Installation
• The radiator controller fits on the most common
radiator valves M30 x 1.5.
• After being mounted, the radiator controller operates
immediately with the factory setting.
Functions for increased comfort
• Individual heating program for each weekday.
• Up to 6 switching points per day and three different
temperatures.
• Operating modes Holiday, Party, Day off can easily be
activated.
• Parameters can be set individually, see Section 9.
Energy-saving functions
• With the window function an open window is
recognised and the radiator valve closed.
• In ECO mode the room temperature is decreased by
3 °C.
• Optimised heating or lowering of the room
temperature.
Danger of malfunctions!
f Use the radiator controller only in
accordance with these operating
CaUtIon
instructions.
f Do not allow children to play with the
radiator controller.
3. Installation
Ready to operate in three steps:
• Inserting batteries
• Setting the language, time and date
• Mounting – FInISHED
- 1 -
Table of Contents
loading

Summary of Contents for Honeywell homexpert Rondostat COMFORT+ HR30

  • Page 1 2. Brief description With the electronic radiator controller you can set your room temperature exactly to your requirements while additionally saving energy. Lowering the room temperature by 1 °C saves approx. 6% energy! User-friendly • Large adjustable display with backlight. •...
  • Page 2: Inserting/Changing Batteries

    Setting the time and date Inserting/changing batteries The radiator controller is set for the following battery 1. When is displayed, use the adjustment dial to hour type: set the current hour and confirm with • 2 Alkaline mignon cells 1.5 V, type LR6, AA, AM3 is displayed.
  • Page 3 2. Turn the adjustment dial of the valve baseplate anti- Valves M30 x clockwise until it stops. 1.5 Honeywell- required 3. Put the valve baseplate onto the radiator valve or the Braukmann, adapter and tighten by hand (without tools!).
  • Page 4: Operating Hints

    Setting the position of the display 7 Adjustment dial: Change settings 8 Button AUTO/ECO/MANU: Change between In order to improve the legibility the display of the automatic, ECO and manual mode radiator controller can be tilted to different positions In programming mode: Terminate (without storing) (10°, 20°, 30°, 40°).
  • Page 5: Programming - Operating Modes

    Week program 1: at home all day Manual mode Factory preset time program is set for each day of the In manual mode the radiator controller operates at week (Mo – Su): the (manually) set temperature until you change the temperature or change to a different operating mode.
  • Page 6: Programming - Time Program

    Selecting the "Day off" operating mode 8. Programming – time program 1. Press the PROG button and turn the adjustment dial to the left until is displayed. day off Planning the time program 2. Confirm the selected operating mode with the You can specify up to 6 switching points per day.
  • Page 7 Setting the time program 4. Use the adjustment dial to set the desired end of the selected switching point and confirm with Selecting weekdays is displayed briefly. Subsequently the saved temperature as well as the beginning and end of the 1.
  • Page 8: Basic Settings

    9. Basic settings Par. Sett. Meaning Upper temperature limit overview The room temperature cannot be set higher than the specified upper temperature limit If desired, you can modify the 16 basic settings. (HI LIMIT). Factory settings have a grey background. Factory setting: 30 °C Parameters marked with an * are described in more...
  • Page 9 When you close the window so that the temperature rises the radiator controller opens the radiator valve again. time temperature If you should ever forget to close the window, the 6:00 – 9:00 radiator controller opens automatically after the set time 20 °C (Comfort temperature 1) in order to ensure frost protection.
  • Page 10: Further Functions

    Parameter 13 – temperature offset 10. Further functions Since the radiator controller measures the room temperature in the area of the radiator, it is possible Monitoring functions that this temperature deviates from the temperature measured at a different point in the room. Window function If, for example, 20 °C is measured in the room and at the If you open a window causing the temperature to drop,...
  • Page 11: Help With Problems

    opening the valve fUse the AUTO/ECO/MANU button to change to automatic mode. – or – fSet the desired temperature in manual operation. – Child-proofing / operation lock You can block the radiator controller to protect it against Restoring the factory setting unauthorised operation: fKeep the AUTO/ECO/MANU and PROG buttons 1.
  • Page 12: Programming Overview

    <––> <––> <––> <––> Beginning Beginning Beginning Beginning <––> End <––> End <––> End <––> End Subject to change in order to improve the product. Novar GmbH Hotline: xxx xxx xxx a Honeywell Company Gartenstraße 49 58511 Lüdenscheid www.homexpertbyhoneywell.com 50076383-001...

Table of Contents