Siemens LOGO Manual
Hide thumbs Also See for LOGO:

Quick Links

PRE-PROGAMMED as 4 CHANNEL 7 DAY TIME SW. with HOLIDAY OFF OVERRIDE
12 PROGRAMMABLE HOLIDAY BLOCK DATES (individual days or group of days)
INDIVIDULE AFTER HOURS PUSH BUTTON INPUTS (AHR up to 99hrs run time)
HOLIDAYS CAN BE SET FOR ONCE OFF OR REPEAT EACH YEAR (ie CHISTMAS)
COMMON HOLIDAY OFF OVERRIDE FUNCTION INTERLOCKABLE WITH EACH OF
THE FOUR TIME SWITCHES.
INDIVIDULE TIME SWITCHES CAN BE SET FOR MULTIPLE ON/OFF's EACH DAY
PLAIN ENGLISH SCROLLING LCD DISPLAY SHOWING OUTPUT & HOLIDAY STATUS
EXISTING HOLIDAY PROGRAM DATE INFORMATION AVAILABLE ON LCD SCREEN
TOGGLE ON / TOGGLE OFF AHR FUNCTION.
DIN RAIL MOUNT, SUITS M.C.B ENCLOSURES
OUTPUT RELAYS ARE POTENTIAL FREE & RATED AT 240v 10A (res.)
MANUAL ALL ON & OFF KEYBOARD FACILITY
This pre-programmed Siemens Logo PLC has been programmed for use as a 4
channel 7 day Time Switch with independent output voltage free relays (240v
rated). Each time switch channel has its own multi on/off per day, 7 days a week
time switch setting schedule plus individual after hours push button inputs. 12
Holiday Start / Finish blocks ( single day or block of days ..ie easter ) can be
programmed as a common off HOLIDAY override to override any or all of the four
time switches but are still able to individually triggered on by the their
independent AHR inputs. The 4 time switches are each preset to operate Monday
to Friday from 08:00 (8 am) till 17:30 (5:30pm), & the after hour timers preset for
2 hours operation, but all settings are user adjustable via the keypad onsite. Two
of the PLC keyboard buttons have been assigned as Master Manual all ON &
OFF buttons, but if left in Manual returns to Auto time switch control after 99
hours if not toggled back to Auto control by again pressing the PLC fascia button.
.
HEVAC CONTROL AGENCIES Pty.Ltd. www.hevac.com.au
PRE PROGRAMMED
4 x 7 DAY TIME SWITCH
c/w INDIVIDULE AHR I/P's
+ common 365 DAY HOLIDAY OFF override
24v AC or DC POWERED
VOLTAGE FRE RELAY OUTPUTS
03 95627888
SIEMENS
240V VERSION AVAILABLE
(WILL AUTO RETURN TO AUTO AFTER 99HRS)
LOGO as 4 channel 365 T/Switch
LOGO PLC as
updated 24/03/2020
loading

Summary of Contents for Siemens LOGO

  • Page 1 • (WILL AUTO RETURN TO AUTO AFTER 99HRS) This pre-programmed Siemens Logo PLC has been programmed for use as a 4 channel 7 day Time Switch with independent output voltage free relays (240v rated). Each time switch channel has its own multi on/off per day, 7 days a week time switch setting schedule plus individual after hours push button inputs.
  • Page 2: Operational Notes

    THE FOUR INDEPENDANT TIME SWITCH AFTER HOUR PUSH BUTTON INPUTS CAN BE LOOPED TO OPERATE FROM A COMMON SINGLE PUSH BUTTON OR ANY COMBINATION THAT IS REQUIRED. PLC CONTROL PANEL OPTIONAL AHR PUSH BUTTONS updated 24/03/2020 HEVAC CONTROL AGENCIES Pty.Ltd. www.hevac.com.au 03 95627888 LOGO as 4 channel 365 T/Switch...
  • Page 3 ANOTHER PARAMETER TO EDIT & REPEAT. TO RETURN TO THE NORMAL RUNNING SCREEN, PRESS UNTIL ONLY THE TIME & DATE SCREEN IS DISPLAYED, THEN PRESS THE BUTTON UNTIL THE DISPLAYED SCREEN NO LONGER CHANGES, THIS RETURNS THE LOGO TO ITS NORMAL DISPLAY & OPERATION.
  • Page 4 4 CHANNEL TIME SWITCH EDITABLE PARAMATER LIST LOGIC BLOCK LCD SCREENS SHOWING BLOCK # OR TAG HOLIDAY 1 B001 HOLIDAY 2 B002 HOLIDAY 3 B003 HOLIDAY 4 B004 B005 HOLIDAY 5 B006 HOLIDAY 6 (B007) HOLIDAY 7 HOLIDAY 8 (B008) HOLIDAY 9 (B009) HOLIDAY 10...
  • Page 5 EXAMPLE LCD SCREENS FOR EDITING 7 DAY TIME SWITCH 1 HIGHLIGHT "D1" TO SET WHICH DAYS OF THE WEEK ARE TO BE CONTROLLED BY THIS PARTICULAR INTERNAL TIME SWITCH, USE UP, DOWN, LEFT & RIGHT BUTTONS TO SELECT DAYS ( " "...
  • Page 6: On+Off Timers

    EXAMPLE LCD SCREENS FOR EDITING DELAY TIMERS HIGHLIGHT THE "T" VALUE USING THE UP, DOWN, LEFT, RIGHT & OK BUTTONS TO SET REQUIRED VALUE. PRESS THE "ESC" BUTTON TO RETURN TO THE PROGRAM BLOCK LIST . REPEATEDLY PRESS "ESC" TO EXIT THE EDITING SCREENS &...