DOK-MOTOR*-MCL********-PR05-EN-P
Rexroth IndraDyn L Ironless Linear Motors MCL
8
Connection technique
8.1
Power connection
8.1.1
Connection cable on primary part
Primary parts of MCL motors are fitted with a flexible and totally shielded con‐
nection cable. This 1100 mm long connection cable is connected with the pri‐
mary part.
①
Primary part MCP
②
Connection cable power
①
Connection cable (Hall unit - optional bei MCP020 ... 070; see
Fig.8-8)
①
Wires with wire end ferrules (wire designation acc. to DIN EN
60445)
Fig. 8-1:
Design of connection cable (power) on the primary part MCP
Wire designation on power connection cable
Designation
MCP015
U
BN (YE)
V
BK (GN)
W
GY (BU)
PE
not applicable
TP(+)
not applicable
TP(-)
not applicable
Shield
1)
Colors in brackets can be transitionally available.
Tab. 8-1:
Wire designation (power) on MCP primary parts
DANGER
Prepare a suitable connection with a protective switch via the primary part
carrier when using AC voltage > 50 V or DC > 120 V (DIN IEC 60364-4-41).
Bosch Rexroth AG
MCP020 ... 070
1)
1
2
3
7
8
Shield
Exceeding of voltage limits!
83/193
Connection technique
1)
BN (YE)
BK (GN)
GY (BU)
GNYE
PK
WH (GY)
Shield