Available languages

Available languages

Quick Links

Getting Started
This is a brief document designed to quickly get you started setting up your valve manifold with an integrated
Numatics' G2-2 DeviceLogix communication node.
1) Initial Unpacking and Inspection
1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.
2) Remove wrapped manifold assembly from box.
a) Remove manifold assembly from anti-static packaging
b) Retain documentation for installation and configuration
3) Examine manifold assembly for any shipping damage such as:
a) Bent pins or connectors
b) Report any damage to shipping carrier immediately
4) Examine manifold assembly for proper ordered configuration. (Valves, I/O, Protocol, etc.)
2) G2-2 Introduction
Below is an example of a 2012 series valve manifold. This fieldbus manifold series is capable of addressing a
total of 224 I/O. The manifold can be viewed as having two sections to it, the
Side
. The
Valve Side
maximum of 6 modules totaling 192 Outputs, 96 Inputs, or various combinations if used as a DeviceNet node.
When being used as a DeviceLogix node the
bindable inputs. The communication module has two connectors: a 5-pin communication connector and a
4-pin power connector. Pin-outs for these, along with I/O connectors, are labeled on the side of the respective
modules.
Dual 25 Pin Sub-D
w/Aux Power
Output Module
Analog Module
G2-2 Series DeviceLogix Quick Start Manual
supports a maximum of 32 solenoid coils and the
Discrete I/O
Connectors
I/O Point
LED Status
Indicator(s)
19 Pin Round
Connector Module
8 Connector I/O Module
3835054 TDG22DLQS3-0
Subject to change without notice
www.numatics.com/fieldbus
Discrete I/O Side
is capable of 48 bindable outputs and 96
Discrete I/O Side
(Maximum of 6 Modules)
Module/
Network
Status LED's
NET STATUS
MOD STATUS
RUN/FORCE I/O
FUSE 1
+24V VLV/OUT
FUSE 2
+24V NODE/IN
Device Logix
TM
Manual Configuration
Terminal Strip Module
Module (MCM)
1/07
Valve Side
and the
Discrete I/O Side
supports a
Valve Side
(Maximum of 32 Solenoids)
Chassis Ground
Connection
Valve
End Plates
Valve
Valve Side
Sub-D Output
Module
Communications
Module (Node)
Solenoid LED
Status Indicator
Discrete I/O
Manual
Override
Page 1
Table of Contents
loading

Summary of Contents for Emerson Numatics DeviceLogix G2-2 Series

  • Page 1 G2-2 Series DeviceLogix Quick Start Manual Getting Started This is a brief document designed to quickly get you started setting up your valve manifold with an integrated Numatics’ G2-2 DeviceLogix communication node. 1) Initial Unpacking and Inspection 1) Examine exterior of package for signs of damage. Report any damage to shipping carrier. 2) Remove wrapped manifold assembly from box.
  • Page 2: Mcm - Manual Configuration Module (Optional)

    G2-2 Series DeviceLogix Quick Start Manual 3) MCM - Manual Configuration Module (Optional) DIP Switch Rotary Switch (SW2) (SW3) DIP Switch Rotary Switch (SW1) (SW4) 5 6 7 8 5 6 7 8 All DIP switches shown in the "OFF" position The MCM is the module that allows the user to manually set baud rate, MAC ID and other user definable options, without the need for software configuration.
  • Page 3 G2-2 Series DeviceLogix Quick Start Manual MCM Settings DIP Switch Settings (SW1) Baud Rate: SW1-1 SW1-2 Kbaud Off* Off* 125* Autobaud: Switch Setting Description Autobaud Enabled (baud rate configures automatically for 125Kbps, SW1-4 Off* 250 Kbps, and 500 Kbps) Autobaud Disabled (set the baud rate manually either through switches or SW1-4 software) Manual or Software Configuration:...
  • Page 4: Self-Test Mode

    G2-2 Series DeviceLogix Quick Start Manual 4) Self-Test Mode An internal diagnostic tool can also be enabled using the optional MCM module. This tool allows the user to confirm that all of the Inputs and Outputs on the manifold are fully functional without needing a network connection or controller.
  • Page 5 G2-2 Series DeviceLogix Quick Start Manual 5) I/O Mapping Example Example: Assumed Settings - Single Z-Boards used with single solenoid valves - Double Z-Boards used with double solenoid valves For simplicity, two mapping formats are given to match appropriate software tools (i.e. DeviceLogix is for the logic editor function within RSNetworx DeviceNet).
  • Page 6 G2-2 Series DeviceLogix Quick Start Manual DeviceLogix (Logic Editor) I/O Mapping Table Example Continued Discrete Output Table Output 0 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Valve Coil No. 1 Valve Coil No. 2 Valve Coil No.
  • Page 7 G2-2 Series DeviceLogix Quick Start Manual DeviceNet I/O Mapping Table Example Continued Output Table BYTE Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Valve Coil Valve Coil Valve Coil Valve Coil Valve Coil Valve Coil Valve Coil Valve Coil...
  • Page 8: Ground Wiring

    G2-2 Series DeviceLogix Quick Start Manual 6) Output Short Circuit Protection (Status Input Bits) Status Input Bits report the integrity of the load being driven by the output driver. They must be mapped to the scanner as part of the Input Size Value. Please refer to the table below for Status Input Bit action during fault condition: Output Type Output State...
  • Page 9 G2-2 Series DeviceLogix Quick Start Manual 8) Communication Module Connector Pin-Outs DeviceNet Communication Connector Pin-Out Pin No. Function Description Shield Cable shield Bus Power, 11-25VDC Bus Power, Common CAN_H Controller Area Network High, Communication Line CAN_L Controller Area Network Low, Communication Line Auxiliary Power Connector Pin-Out Standard Cenelec...
  • Page 10: Led Functions

    G2-2 Series DeviceLogix Quick Start Manual 9) LED Functions Upon power up, the LEDs indicate the status of the unit. There are seven LEDs on the G2-2 DeviceLogix node; Network Status, Module Status, Run/Force I/O, two for internal fuse integrity, and two for Aux. Power status.
  • Page 11: Function Block

    G2-2 Series DeviceLogix Quick Start Manual 10) Function Block Numatics DeviceLogix nodes integrates all four types of function blocks; Boolean, Bistable, Counter and Timers. A maximum of 72 function blocks, in any combination, can be used to develop a program sequence. Boolean Bistable Counter...
  • Page 12 G2-2 Series DeviceLogix Quick Start Manual 12) Stand-Alone Versus Networked Functionality The Numatics DeviceLogix communication node can be used as a stand-alone programmable device or as part of a DeviceNet network. Using the RSNetworx for DeviceNet software, different settings must be enabled or disabled to configure these options.
  • Page 13 G2-2 Series DeviceLogix Quick Start Manual Network/Communication Settings The following table describes the behaviors that occur when the Network Status Override and Communication Status Override attributes are disabled. The user may have the DeviceLogix node begin local logic mode in “Comm Status Override”...
  • Page 14: Factory Default Settings

    G2-2 Series DeviceLogix Quick Start Manual 13) G2-2 DeviceLogix Features Features Description DeviceNet Spec. Supported Designed to DeviceNet Specification Revision 2.0 Bus Topology Straight with restricted drops Baud Rates Supported 125Kbps, 250 Kbps and 500 Kbps and Autobaud If duplicate address detected on power up, duplicates will not Duplicate address detection progress to run mode Error Correction...
  • Page 15: Pour Commencer

    Guide de Démarrage Rapide Série 2-2 - DeviceLogix Pour commencer Ce document décrit le démarrage rapide de votre îlot de distribution à nœud de communication DeviceLogix série G2-2 intégré. 1) Déballage et inspection 1) Inspectez l'emballage extérieur pour détecter tout dommage. Tout dommage constaté doit être signalé au transporteur.
  • Page 16 Guide de Démarrage Rapide Série 2-2 - DeviceLogix 3) MCM – Module de configuration manuelle (option) DIP Switch Rotary Switch (SW2) (SW3) DIP Switch Rotary Switch (SW1) (SW4) 5 6 7 8 5 6 7 8 All DIP switches shown in the "OFF" position Le MCM (module de configuration manuelle) permet à...
  • Page 17 Guide de Démarrage Rapide Série 2-2 - DeviceLogix Réglages du MCM Réglages des DIP switchs (SW1) Taux Baud SW1-1 SW1-2 Kbaud Off* Off* 125* Autobaud : Switch Réglage Description Autobaud activé (le taux baud est automatiquement configuré à 125 Kbps, SW1-4 Off* 250 Kbps ou 500 Kbps).
  • Page 18 Guide de Démarrage Rapide Série 2-2 - DeviceLogix 4) Mode auto-test Un outil diagnostic interne peut également être activé par le module MCM optionnel. Cet outil permet à l'utilisateur de s'assurer que toutes les entrées et sorties sur l'îlot sont complètement opérationnelles, sans besoin de connexion réseau, ni de contrôleur.
  • Page 19 Guide de Démarrage Rapide Série 2-2 - DeviceLogix 5) Exemple de mapping des E/S Réglages présumés Exemple: - Cartes Z-Boards simples utilisés avec les électrodistributeurs simples - Cartes Z-Boards doubles utilisés avec les électrodistributeurs doubles Pour assurer la simplicité, il existe deux formats de mapping adaptés aux outils de logiciel appropriés (c.à.d.
  • Page 20 Guide de Démarrage Rapide Série 2-2 - DeviceLogix Exemple de Mapping des E/S DeviceLogix (éditeur logique – continuation) Tableau des sorties discrètes Sortie 0 Sortie 1 Sortie 2 Sortie 3 Sortie 4 Sortie 5 Sortie 6 Sortie 7 Bobine no. 1 Bobine no.
  • Page 21 Guide de Démarrage Rapide Série 2-2 - DeviceLogix Exemple de Mapping des E/S DeviceNet - continuation Tableau des sorties OCTET Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Valve Coil Bobine no. 8 Bobine no.
  • Page 22: Mise À La Terre

    Guide de Démarrage Rapide Série 2-2 - DeviceLogix 6) Protection des sorties contre les courts-circuits (bits d'entrée d'état) Les bits d'entrée d'état signalent l'intégrité de la charge pilotée par le pilote de sortie. Ils doivent être mappés sur le scanner comme partie de la valeur de la taille de l'entrée. Voir le tableau ci-dessous pour l'action du bit d'entrée d'état lors de l'occurrence d'une condition de défaut : Etat de la Type de sortie...
  • Page 23 Guide de Démarrage Rapide Série 2-2 - DeviceLogix 8) Affectation des broches du connecteur du module de communication Affectation du connecteur de communication DeviceNet No. de broche Fonction Description Blindage Blindage de câble Tension bus, 11-25VCC Tension bus, commun Réseau CAN (Controller Area Network) high, ligne de CAN_H communication Réseau CAN (Controller Area Network) low, ligne de...
  • Page 24 Guide de Démarrage Rapide Série 2-2 - DeviceLogix 9) Fonction des voyants LED A la mise sous tension, les voyants LED indiquent l'état de l'unité. Le nœud DeviceLogix G2-2 dispose de sept voyants LED; Network Status (état du réseau), Module Status (état du module), Run/Force I/O (exécuter/forcer les E/S), deux pour pour l'intégrité...
  • Page 25 Guide de Démarrage Rapide Série 2-2 - DeviceLogix 10) Bloc fonctionnel Les noeuds DeviceLogix de Numatics intègrent tous les quatre types de blocs fonctionnels; Boolean (Booléen) (compteur) (temporisateur) , Bistable, Counter et Timer . Un maximum de toute combinaison de 72 blocs fonctionnels peut être utilisé...
  • Page 26 Guide de Démarrage Rapide Série 2-2 - DeviceLogix 12) Fonctionnement autonome vs. fonctionnement en réseau Le nœud de communication DeviceLogix de Numatics peut être utilisé en tant qu'appareil programmable autonome ou en tant que composant d'un réseau DeviceNet. A l'aide du logiciel RSNetworx™ pour DeviceNet, de réglages divers doivent être activés ou désactivés pour configurer ces options.
  • Page 27 Guide de Démarrage Rapide Série 2-2 - DeviceLogix Réglages réseau / communication Le tableau suivant décrit le comportement qui se produit lorsque les attributs "Network Status Override" et Communication Status Override" sont désactivés. L'utilisateur pourra déterminer que le noeud DeviceLogix "Comm.
  • Page 28: Support Technique

    Guide de Démarrage Rapide Série 2-2 - DeviceLogix 13) Caractéristiques du DeviceLogix série G2-2 Caractéristique Description Spécification DeviceNet supportée Etablie conformément à la Spécification DeviceNet Révision 2.0 Topologie de bus Structure en ligne avec un nombre restreint de dérivations. Taux Baud supportés 125Kbps, 250 Kbps et 500 Kbps, et Autobaud.

Table of Contents