Additional information about an operating step Cross-reference to a page Read instructions Result of a step Table title Title of figure Revision history Date Version Description 1 Aug. 2020 01.00 First version Installation Instructions - EmoTouch 3...
Standards and regulations ................9 2 Identification ......................10 Information about the unit................10 2.1.1 Leistungsteil ...................10 2.1.2 EmoTouch 3 control panel ............11 Intended use....................11 3 Description of the units ..................13 Scope of delivery...................13 Technical data ....................15 4 Mounting ........................16 Power supply and data lines ..............16 Installation work inside the cabin ............17...
Page 4
4 additional cabins ..............60 Control lines and cabin addresses ............61 Programming of the cabin address ............63 Setting up a multi-cabin installation............. 64 8 General terms and conditions of service ..........67 9 Disposal ........................70 Installation Instructions - EmoTouch 3...
CAUTION Caution Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Notice Indicates a hazardous situation which, if not avoided, will result in damage to the unit. EmoTouch 3 - Installation Instructions...
Corrosive or heavy saline atmospheres damage the contacts in the control panel, in the relay box and in the sensors. The control panel and sensors should not be installed in a cor- rosive or heavy saline atmosphere. Installation Instructions - EmoTouch 3...
Inspect the cabin prior to commissioning. When using control units with a remote control option (see EN 60335-1), protection from switching on a covered sauna heater is required. EmoTouch 3 - Installation Instructions...
Page 8
Children and persons who have not received proper instruction must not clean or service the system. Installation Instructions - EmoTouch 3...
Electromagnetic compatibility – Requirements for household appliances, electric tools and similar apparatus – Part 1: Emission DIN EN 55014-2 Electromagnetic compatibility – Requirements for household appliances, electric tools and similar apparatus – Part 2: Immunity EmoTouch 3 - Installation Instructions...
Identification Identification The EmoTouch 3 control unit consists of a relay box, a control panel, a tem- perature sensor and the connecting cables, and is used to operate a sauna cabin. Information about the unit 2.1.1 Leistungsteil The nameplate is attached to the underside of the base of the housing.
Storage temperature: -20°C to 60°C Intended use In conjunction with a suitable sauna heater, the EmoTouch 3 control unit is intended to be used only to heat sauna cabins. It is suitable for cabins used in private and commercial settings.
Page 12
The manufacturer is not liable for unauthorised modifications made to the equipment and damages resulting from these modifications. The person modifying the equipment alone shall bear the associated risk. General safety instructions, 5 Installation Instructions - EmoTouch 3...
Description of the units Description of the units EmoTouch 3 consists of a relay box, a control panel, a temperature sensor and connecting cables. Additional modules/devices can be connected to the relay box for total control of a sauna cabin, for example, lighting, fan and additional sensors.
Page 14
94.5920, 94.5921 Infrared receiver for coloured light module and sound mod- 94.6810 SBM-GLT-MOD HOME Modbus module 94.7077 SBM-GLT-KNX HOME KNX module 94.7078 Modular distributor RJ12 for connecting cable for control 2001.5298 panel and sauna bus Installation Instructions - EmoTouch 3...
Min. 5 W (20 mA), resistive load, max. 100 W Dimmable energy-saving bulbs, max. 35 W Light source with conventional transformers, max. 60 VA. Use only dimmable light sources. * Fan and light connections are protected by a joint 2AF fuse. EmoTouch 3 - Installation Instructions...
Routing data and power supply lines together can lead to elec- tronics malfunctions because, e.g. because the sensor will not be detected. Do not route sensor and sauna bus lines together with power supply lines. Route separate cable conduits. Installation Instructions - EmoTouch 3...
Connect the safety temperature limiter only to the relay box. Always connect the safety temperature limiter as an isolated contact. If the installation uses multiple sauna heaters, multiple safety temperature limiters may be required. Observe the separate EOS instructions. EmoTouch 3 - Installation Instructions...
Page 18
Installation configuration – main sensor (heater sensor) distance from wall Cabin smaller than 2 x 2 m Distance from wall 19 cm Cabin larger than 2 x 2 m Distance from wall 35 cm Installation Instructions - EmoTouch 3...
The main sensor must be installed where expected temperatures are the highest. Hardware + tools: Temperature sensor and connecting cables Drill to drill a hole in the cabin ceiling Screwdriver Taut wire, as needed EmoTouch 3 - Installation Instructions...
Page 20
Route the sensor cable through the hole. Open the temperature sensor's housing and connect the sensor bus ca- ble. A White (sensor bus) B Green (sensor bus) C Brown (sensor bus) Temperature sensor connections Installation Instructions - EmoTouch 3...
Page 21
Screw the sensor plate to the cabin ceiling and close the housing. Connecting the sensor line: Schematic view of connections, 36 EmoTouch 3 - Installation Instructions...
It must be possible to control the fan's speed using phase control. The fan can be installed anywhere, however never near hot air that rises from the heater. The fan is not included in the scope of delivery. Observe the separate installation instructions for the fan. Installation Instructions - EmoTouch 3...
The supply line can short circuit if you use the mains connections L1, L2 or L3 to supply the electric circuit connected to the poten- tial-free contact. Use the EmoTouch 3 mains connections only for the sauna heater. Do not connect additional devices to the EmoTouch 3 mains connections.
All lines should be routed before installing the relay box. Connections can be established later. Data lines must be routed and connected in such a way that they are not openly accessible. Installation Instructions - EmoTouch 3...
Page 25
They are then passed into the housing from the rear. In both cases, the cabin insulation must be installed in such a way that the temperature in the area in which cables are routed cannot exceed 75°C. EmoTouch 3 - Installation Instructions...
Remove both halves of the cover. Installing the relay box Drill one (1) hole above and two (2) holes below. Horizontal distance between drill holes: 210 mm Vertical distance between drill holes: 180 mm Installation Instructions - EmoTouch 3...
Page 27
S-Bus (sauna bus) Either from below or from the rear. Insert supplied rubber grommets into the openings of the lower part of the housing. Route the connecting cables through the openings. EmoTouch 3 - Installation Instructions...
5.3 Setting the jumper for maximum heating time, 42 5.5 Connecting and configuring consumers, 44 Control panel The EmoTouch 3 control panel is designed for mounting in the wall. If empty conduits for electrical installations are already present, this dictates the position of the control panel.
Mounting width 189 mm Mounting depth Min. 37 mm Line routing A Insulation C Control line B Inner wall of the cabin D Outer wall of the cabin Guide for data and control line(s) EmoTouch 3 - Installation Instructions...
Plugging in the control panel, 34 Tools required: Saw for wall cut-out Phillips screwdriver Removal tool to loosen the display (included in the scope of delivery) Taut wire, as needed Installation Instructions - EmoTouch 3...
Page 31
Do not drop the control panel. The display's glass plate cannot be replaced. Remove the protective film from the panel after mounting is completed. Insert the two removal tools in the slot at the base of the control panel and carefully remove the display. EmoTouch 3 - Installation Instructions...
Page 32
Slide the clips as far out as they will go and tighten the screws clockwise. The housing must sit firmly in the wall cut-out. Installation Instructions - EmoTouch 3...
Page 33
Slide the ferrite ring onto the bridge on the mounting plate. Connect the control line to socket 1/2 using the RJ10 plug. A Bridge for ferrite ring EmoTouch 3 circuit board – jacks Plug for multi-cabin connection, see 7.1 Configuration options, 56 EmoTouch 3 - Installation Instructions...
Page 34
To remove it, insert the two removal tools in the slots on the lower edge of the control panel and carefully remove the display. Remove the foil from the control panel. For commissioning information, see 6.2 Setup during commissioning or after a reset, 49 Installation Instructions - EmoTouch 3...
Establish connection to the power supply. In a multi-cabin installation: Program the cabin address. Switch on the relay box and control panel. Configure additional settings at the control panel, e.g. target tempera- ture. EmoTouch 3 - Installation Instructions...
G Heater sensor and safety L Vaporiser C Sensor bus temperature limiter M Sauna heater D Reserve H EmoTouch 3 control panel E Humidity sensor Cabin lighting - - - optional J Fan Schematic view of connections In addition to the control panel, another module can be connected to the B jacks for the sauna bus.
When setting a parameter, e.g. temperature, the setting for the other parameter (humidity) is automatically adjusted. Values that lie above the characteristic curve cannot be set. [°C] Characteristic curve for temperature/humidity according to EN 60335-2-53 EmoTouch 3 - Installation Instructions...
Page 38
If the bench sensor fails, the heater sensor regulates the temperature. Circuit board connections A Humidity sensor C Heater sensor (main sensor) B Bench sensor RJ10 connections for sensor Set the desired values for the temperature and humidity on the control panel. Installation Instructions - EmoTouch 3...
The terminals for light may be used only for cabin lighting. A fan with 5 W to 150 W may be connected to the fan terminal. The fan may not have a starting capacitor. Fan and light connections are protected by a joint 2AF fuse. EmoTouch 3 - Installation Instructions...
Page 40
WM input of the control unit. Note the following when connecting a vaporiser: The neutral conductor (N) of the vaporiser must be connected. Observe the maximum switching output of the vaporiser outlet. Installation Instructions - EmoTouch 3...
Page 41
If the Wb and Wm connections on the vaporiser are swapped, the vaporiser will not switch off and continue to run uninterrupted. If the line to Wm is disconnected, the Water shortage error message has to appear. EmoTouch 3 - Installation Instructions...
For this setting, the heating time must be switched off manu- ally. The setting is permitted only if the sauna is used commercially and monitored. The jumpers are included with the device and are connected by blind plug- Installation Instructions - EmoTouch 3...
A RJ10 plug for sensor line B RJ14 plug from control panel Plug the S-Bus line RJ10/RJ14 from the control panel into the free jack RJ12 (S-BUS). Connect shielding of the line to ground if necessary. EmoTouch 3 - Installation Instructions...
For information about the fan, see Fan requirements, 23. Vaporiser 3 kW Sauna heaters 9 kW If the entire output exceeds these values, an additional circuit breaker must be connected, e.g. LSG18H. See the installation instructions for the relevant LSG. Installation Instructions - EmoTouch 3...
Page 45
This results in an asymmetrical heating load and power flows through the neutral conductor. Note the switching output of the heater: max. 9 kW. Connect the mains connection to the (A) terminals. EmoTouch 3 - Installation Instructions...
If the green LED is flashing, replace the housing cover. b) If the green LED is not flashing, troubleshoot the problem and resolve First put the lower then the upper cover halves in place. Screw in the 6 screws. Installation Instructions - EmoTouch 3...
All cabin settings are made at the control panel. All functions must be configured to commission the system. Add-on modules or accessories are detected after the unit is switched on again and their corresponding icons appear in the sub-menus. EmoTouch 3 - Installation Instructions...
6.1.1 User interface icons 01. June 2019 0:45:40 14:22:38 EmoTouch 3 control panel (example) The touch screen icons are displayed in various colours: Grey: Function button is inactive White: Function available or selected Green: Function button Confirm is selected ...
Set the time and confirm. Set the date and confirm. Specify and confirm the place of operation. European Union/CENELEC must be selected if the system is installed in countries under the jurisdiction of the CENELEC. EmoTouch 3 - Installation Instructions...
Page 50
Confirm the confirmation prompt. If you do not confirm the safety device, the settings for the remote start module, the Web App WCI module and the timer are deactivated. Select the heater type and confirm. Installation Instructions - EmoTouch 3...
The current setting is shown on the display when the lighting is dimmed. Display symbol Setting Code Inductive/resistive load (lighting for phase con- 8001 trol), if light bulbs are used. Factory setting Capacitive load (lighting for phase control) 8002 Electrical ballasts for phase-cut dimmer EmoTouch 3 - Installation Instructions...
Page 52
7 8 9 01. June 2019 08:44:40 Code 8001: Inductive load/resistive load, e.g. if light bulbs are used. Code 8002: Capacitive load. Disconnect the relay box from the mains supply and reconnect the light source. Installation Instructions - EmoTouch 3...
Page 53
Press and hold the light icon on the display for 3 seconds. 01. June 2019 12:45:40 Setting Light 100% 01. June 2019 12:45:40 The icon for the current lighting load setting is displayed. Check the setting on the display. EmoTouch 3 - Installation Instructions...
Too many add-on modules connected. Connect modules with separate power adaptor. Bus connection plug not plugged in. Plug in plug. Bus cable damaged. Replace bus cable. Unit not detected. Set unit address for the module. Other errors Software error. Restart unit. Contact technical support. Installation Instructions - EmoTouch 3...
Installing multiple cabins Installing multiple cabins The EmoTouch 3 control panel can be used to set and control multiple cab- ins. Any combination of up to 8 sauna, infrared and/or steam cabins can be connected, e.g.: EmoTouch 3 SAUNA SAUNA...
Installing multiple cabins Configuration options To control multiple cabins with one EmoTouch 3 control panel, you must connect, program, and set up the cabins and relay boxes accordingly. The lines must be connected according to the operating mode that is selected at the time of startup.
All relay boxes are set by the factory to cabin address 1. See also the following figures: Jacks – sauna cabin relay box, 61 Jacks – EmoTouch 3 circuit board, 61 EmoTouch 3 - Installation Instructions...
Jacks – sauna cabin relay box The relay boxes for steam room or IR cabins are described in detail in sepa- rate instructions. Jacks – EmoTouch 3 circuit board EmoTouch 3 - Installation Instructions...
Page 62
Once the cabins with their custom cabin address (IDs) are connected, the icon for the selected cabin is displayed in the footer. The number corresponds to the cabin currently selected (not the number of connected cabins). Installation Instructions - EmoTouch 3...
Installing multiple cabins Programming of the cabin address The EmoTouch 3 relay box is programmed with cabin address 1 as deliv- ered. To ensure that EmoTouch 3 detects multiple cabins, the cabin address must be changed to a different cabin address starting with cabin 2.
4.4.2 Mounting the control panel, 30 NOTICE The connection must always start with jack #1. The connection sequence must be adhered to exactly. Plug the relay box for cabin 1 into jack #1 on the control panel. Installation Instructions - EmoTouch 3...
Page 65
Plug the relay box for cabin 2 into jack #2 on the relay box for cabin 1. EmoTouch 3 automatically switches to multi-cabin mode. On the display, the new cabin in grey is displayed until the cabin address has been programmed.
Page 66
If the small cabin icon is displayed in grey, the cabin has not been detected. Check the cabin address and the connection sequence on the EmoTouch 3 control panel. Repeat programming if the cabin is not displayed. Please note that the address increases by one each time you press the programming button, e.g.
III. Performance and cooperation obligations The customer shall provide assistance free of charge to the manufacturer in rendering services. In the case of a warranty claim, the manufacturer shall provide replace- ment parts necessary for servicing free of charge. EmoTouch 3 - Installation Instructions...
Page 68
Only original replacement parts may be used within the warranty period. Service visits made by third parties shall require a written order issued by our service department. Installation Instructions - EmoTouch 3...
Page 69
The manufacturer's General Terms and Conditions of Business, in the ver- sion available at www.eos-sauna.com/agb, shall apply in addition to the foregoing terms and conditions of service. EmoTouch 3 - Installation Instructions...
Do not dispose of the unit with household waste. Packaging The packaging of the EmoTouch 3 can be completely separated for dis- posal and recycled. The following materials are used in the packaging: Used paper, cardboard ...