Outdoor Fan / Fan Motor - Daikin 2MXS18NMVJU Service Manual

Outdoor unit removal procedure 18000/24000/28000/34000/36000 btu/h class
Hide thumbs Also See for 2MXS18NMVJU:
Table of Contents

Outdoor Fan / Fan Motor

2. Outdoor Fan / Fan Motor
Warning
 Be sure to wait for 10 minutes or more after turning off all power supplies before
Step
1
Remove the drip proof
cover.
2
Disconnect the
connector [S70].
3
Release the fan motor
lead wire from the
groove and the hook.
4
disassembling work.
Procedure
Drip proof cover
[S70]
Hook
Groove
Fan motor lead wire
Points
(R22283)
[S70]: fan motor
 When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
(R22284)
Lead wire
(R22285)
Removal Procedure
Si121558EC
Outdoor fan
(R3249)