Honeywell MicroniK 200 R7426D Installation & Start-Up Instructions

Universal input controller

Quick Links

MicroniK 200
Fig. 1. Temperature Controller
Contents
General ................................................................................ 1
Before Installation Note ....................................................... 1
Mounting .............................................................................. 1
Wiring .................................................................................. 2
Power Supply and Grounding.............................................. 2
Configuration and Control Parameters ................................ 3
Configuration Settings ......................................................... 5
Parameter Settings and Adjustment .................................... 6
Operating Overview ............................................................. 9
7157 585
UNIVERSAL INPUT CONTROLLER
INSTALLATION & START-UP INSTRUCTIONS

GENERAL

This document provides instructions and procedures for
installing and starting up the Micronik 200 R7426D controller.
No special tools are required for mounting and installation.
The user interface and LC display allows accurate and easy
parameter setting and output adjustment.

BEFORE INSTALLATION NOTE

Visually inspect equipment for shipping damage.
Report any damage to the appropriate Honeywell
representative.
Refer to job drawings for specific installation
information and mounting location.
Verify the controller will be adequately separated from
the main power supply, relays or other equipment
which can possibly generate electromagnetic inter-
ference.
Verify that the ambient temperature and the humidity
at the controller will be within the limits of 0...50° ° ° ° C
(32...122° ° ° ° F) and 5 to 95% rh.
Use shielded wiring in areas with high EMI.
All wiring should be separated from power lines by at
least 150mm (6'').
Do not install controllers near frequency converters
or other high frequency sources.

MOUNTING

The controller can be mounted in an electric cabinet or an
other suitable enclosure. It is suitable for back panel, DIN rail,
wall or front panel mounting with an additional available front
panel mounting frame. The mounting sequence of each as
well as dimensions and panel cut-out is illustrated in the
mounting instruction sheet EN1B-0202GE51 supplied with
the controllers.
If the compensation sensor signal (T3) is received from
another controller (parallel connection of compensation
sensor inputs), the jumper W303 must be cut before
mounting the controller (see Fig. 2). This disconnects the
sensor from the internal power supply.
HONEYWELL
R7426D
EN1B-0204GE51 R0403
Table of Contents
loading

Summary of Contents for Honeywell MicroniK 200 R7426D

  • Page 1: Table Of Contents

    INSTALLATION & START-UP INSTRUCTIONS GENERAL This document provides instructions and procedures for installing and starting up the Micronik 200 R7426D controller. No special tools are required for mounting and installation. The user interface and LC display allows accurate and easy parameter setting and output adjustment.
  • Page 2: Wiring

    R7426D UNIVERSAL INPUT CONTROLLER WIRING Screwless type, spring loaded terminals are provided on the Wiring should be done only according to the actual job wiring controllers for wiring. These terminals are suitable for solid diagrams or wiring diagrams shown in the mounting conductors as well as tinned or with multicore cable end, instruction sheet EN1B-0202GE51.
  • Page 3: Configuration And Control Parameters

    R7426D UNIVERSAL INPUT CONTROLLER CONFIGURATION AND CONTROL PARAMETERS Config. Par. Description Default Setting Actual Value No. Name C.01 DIR/REVY1 Selects the output action of Y1 to adapt the valve or damper direction Direct acting output signal Reverse acting output signal C.05 CPATYP Selects the Control Point /SetPoint Adjustment type Potentiometer...
  • Page 4 R7426D UNIVERSAL INPUT CONTROLLER Control Par. Setting Reso- Unit Actual Value Description No. Name High Def. lution P.01 W1 Main setpoint for input X1 P.02 Wlim Limit setpoint (low or high) for input X2 °C P.03 Wcomp Compensation changeover point for input T3 P.04 Wi Winter compensation authority -350...
  • Page 5: Configuration Settings

    R7426D UNIVERSAL INPUT CONTROLLER CONFIGURATION SETTINGS All configuration parameters have to be set to select the Automatic Temperature correct control functions as required for the job application. identification Characteristics range of sensor type Direct - Reverse Action Dir/RevY1 (C.01) Pt 1000 -30..+130°C 1000Ω...
  • Page 6: Parameter Settings And Adjustment

    R7426D UNIVERSAL INPUT CONTROLLER Off Delay for On/Off Output (C.26) Reset Span Adjustment R (P.07) The On/Off output is controlled by the Plant / System On/Off The reset span adjustment R determines the reset effect in input and provides an Off switching output with adjustable %, the submaster setpoint W is altered, if the main input delay time e.g.
  • Page 7 R7426D UNIVERSAL INPUT CONTROLLER Setting Guidelines for Reset Time of The following rule-of-thumb formula are used for P+I+D control: P, P+I and P+I+D Control • Discharge air control The reset time tr should be adjusted to 2...3 times of the response time T , which is the time interval between the beginning of a sustained disturbance (e.g.
  • Page 8 R7426D UNIVERSAL INPUT CONTROLLER Start Point Ystart (P.15) Room Outdoor Air Throttling Control Humidity Temp. Range The start point setting determines the relationship between Schedule (X1) (T3/T the midrange shift of the output Y1 and the corresponded comp calculated control point. 50%rh 20°C 5%rh...
  • Page 9: Operating Overview

    R7426D UNIVERSAL INPUT CONTROLLER OPERATING OVERVIEW Display Controller Mode Display and Operation Elements The MicroniK 200 user interface is described in Fig. 4 Engineering Units Note: Pushing the + or - button increments/decrements values or scrolls through the parameter list: •...
  • Page 10 R7426D UNIVERSAL INPUT CONTROLLER Time Out After approximately 10 min of inactivity (no button has been pressed: time out) each mode returns automatically to standard display mode. Inputs that have not been confirmed by the SET button are ignored by the controller and old parameter values will be retained.
  • Page 11 R7426D UNIVERSAL INPUT CONTROLLER Selecting Parameters The parameter/configuration selection mode is used to select control and configuration parameters (Fig. 7) for adjustment. The displayed parameter no. corresponds with the number in Table 3 and Table 4. Default programming is indicated by a display of def.
  • Page 12 R7426D UNIVERSAL INPUT CONTROLLER Selecting Output Values The output selection mode displays the output value and : Manual Override indicates the manual override (see Fig. 9). An activated manual override is indicated by a displayed F (fixed). is active Pushing the SET button enters the adjustment mode. Without Manually Overriding Output Values Control Loop...
  • Page 13 R7426D UNIVERSAL INPUT CONTROLLER Interpreting Error Messages Different analog input errors can be identified by the Note: For the external CPA/SPA potentiometer input, no controller (Error handling). The defective input (X1, X2, T3) error message is indicated if the potentiometer or wiring is will be displayed in the standard display mode (see Fig.
  • Page 14 R7426D UNIVERSAL INPUT CONTROLLER Automation and Control Solutions Honeywell AG Böblinger Straße 17 D-71101 Schönaich Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://europe.hbc.honeywell.com Subject to change without notice. Printed in Germany Manufacturing location certified to 7157 585 EN1B-0204GE51 R0403...

Table of Contents