GE
Appliances
GE Window Type Air Conditioner
AEV07KP, AEV09KP, AEV12KP, AEV18KP,
AEV24KP, AEE07KP, AEE09KP, AEE12KP,
AEE18KP, AEE24KP
Use & Care Manual
Table of Contents
loading

Summary of Contents for GE AEV07KP

  • Page 1 Appliances GE Window Type Air Conditioner AEV07KP, AEV09KP, AEV12KP, AEV18KP, AEV24KP, AEE07KP, AEE09KP, AEE12KP, AEE18KP, AEE24KP Use & Care Manual...
  • Page 3: Table Of Contents

    To get the full benefit from your new Window Type Air Conditioner, please read this Use & Care Manual carefully before operating the unit. Thank you for choosing a GE Window Type Air Conditioner. Please keep this manual for future consultation. GE Window Type Air Conditioner...
  • Page 4: Structure Mechanism And Installation

    Structure Mechanism and Installation FUNCTION Introduction Autumn Spring Window type room air conditioners of GE can regulate the room Summer Winter Room temperature and dry the room. It is convenient for your work, study temp. and life. It can be widely used in residence, shop, hotel, office, library and laboratory, and so on.
  • Page 5: Operating Condition

    Structure Mechanism and Installation OPERATING CONDITION Please operate air conditioner in the correct conditions as following. COOL mode operation Outdoor temperature should be in range of 16 ~ 43°C (61~86°F), otherwise it is possible for air conditioner to breakdown. Room humidity should be lower than 90%. Otherwise, it is possible for air conditioner to dew at air conditioner surface and even drop water after running for so much time.
  • Page 6: Installation

    Structure Mechanism and Installation INSTALLATION Installation precaution: Window type conditioner is so valuable and the improper installation of it will cause a lot of damage! Please associate the professional technician to install the unit and don't install it by yourself. Otherwise, we are not responsible for the damage like this.
  • Page 7 Structure Mechanism and Installation Installation procedure: 1) Remove the sticker from the front panel. 2) Put the unit into the installation hole. Horizontal line • When installing the unit, it should be slanted down to the back to avoid the enlargement of noise or vibration. (Slant between 6-10mm.) 6~10mm (Shown at right figure.) •...
  • Page 8 Structure Mechanism and Installation Drain water: To get the maximum cooling efficiency, the air conditioner is designed to splash the condensation water on the condenser coil. To the cooling only unit,If the splashing sound annoys you, you can provide an outside drain by using the following procedure, whichmay however cause a small loss of performance.
  • Page 9: Notes For Installation

    Structure Mechanism and Installation NOTES FOR INSTALLATION Remove Before removing air conditioner to the other place, you should contactthe seller firstly. Then it must be done under the direction of the professional technician. In addition, the charge of this must be paid. Noise •...
  • Page 10: Operation Procedure

    Operation Procedure PART IDENTIFICATION Panel outlook picture, just for reference, please take the real until as standard. Cabinet Air inlet louver Front grille Front intake grille) Control Panel Power cord Air filter (behind the front intake grille) AIR DIRECTION ADJUSTMENT Vertical airflow direction vane (Airflow direction adjustment up and down).
  • Page 11: Operation For Mechanical Model

    Operation Procedure OPERATION FOR MECHANICAL MODEL HIGH COOL TURBO COOL 1. Main Control Knob Set to Low Cool, High Cool or Turbo Cool as desired (FAN setting operates the fan only.) CAUTION: If the main control knob is turned off or changed to a fan setting from a cooling operation setting.
  • Page 12: Operation Of Remote Control For Electronic Model

    Operation Procedure TEMP/TIMER BUTTON Press the ▲ to increase the set (operating) temperature of the unit.and Press the ▼ to decrease the set (operating) temperature of the unit. The temperature seting range is from 16~30°C (61~86°F). Press the ▲ also to increase the selected time, and Press the ▼ to decrease the selected time. The time setting will be modified in steps of half an hour at a time when less than 10 hours, and in steps of an hour for more than 10 hours.
  • Page 13 Operation Procedure Temp Increase ▲ /Decrease ▼ Buttons Use to set temperature except Auto mode. Delay Timer Increase ▲ (+) /Decrease ▼ (-) Buttons Each touch of the Increase ▲ / Decrease ▼ buttons on the unit or the Increase+ / Decrease - buttons on the remote control will set the delay time when using the Delay 0.5-24hr timer (DELAY).
  • Page 14 Operation Procedure Cooling Descriptions For Normal Cooling–Select the Cool mode and High or Turbo fan with a middle set temperature. For Maximum Cooling–Select the Cool mode and Turbo fan with a lower set temperature. For Quieter & Nighttime Cooling–Select the Cool mode and Low fan with a middle set temperature. Energy Saver Mode The fan will cycle on and off with the compressor.
  • Page 15: Operation Tips

    Operation Procedure OPERATION TIPS Operation for comfort and economy Do not overcool the room Keep blind or curtains closed. Keep the room temp. uniform. temperature. This is not good for Do not let sunshine enter the Adjust the vertical and horizontal health and wastes electricity.
  • Page 16: Care And Maintenance

    Care and Maintenance CAUTION Operations for safety and health 1) The plug must be accessible after the appliance is positioned. 2) Do not use this appliance in the laundry. 3) If the power cord is damaged, it must be replaced by the manufacture or its service agent in void of hazard.
  • Page 17: Care And Maintenance

    Care and Maintenance CARE AND MAINTENANCE Always turn off the air conditioner and main power supply before cleaning to ensure safety. Cleaning unit 1. Cut power off before cleaning. Air filter The air filter behind the intake grille should be Plug out only washed at least once every two weeks or as afterair conditioner...
  • Page 18: Trouble Shooting Guide

    Care and Maintenance TROUBLE SHOOTING GUIDE Please check the following items before asking for repair, it saves your time and money. Fault phenomenon Trouble-shooting • Is there a power failure? Air conditioner dose not • Is the plug out? operate at all. •...
  • Page 19: After Service

    Care and Maintenance AFTER SERVICE • If your air conditioner has the questions of quality or anything else, please contact the service center of GE. ※Working temperature range Indoor Side DB/WB( Outdoor Side DB/WB( ℃ ℃ Maximum Cooling 32/23 43/26...
  • Page 20 66129910152...

Table of Contents