6.2 Opening and closing the units

6.2.1 About opening the units

Installer reference guide
46
Maximum height difference between indoor unit and outdoor
unit
Maximum total water piping length
(a)
Precise water piping length can be determined using the Hydronic Piping
Calculation tool. The Hydronic Piping Calculation tool is part of the Heating
Solutions Navigator which can be reached via
professional.standbyme.daikin.eu. Please contact your dealer if you have no access
to Heating Solutions Navigator.
Mind the following spacing installation guidelines:
≥500
INFORMATION
If you have limited installation space, do the following before installing the unit in its
final position:
remove one or both side panels.
The foundation must be strong enough to bear the weight of the unit. Take the
weight of the unit with a domestic hot water tank full of water into account.
Make sure, in the event of a water leak, water cannot cause any damage to the
installation space and surroundings.
Do NOT install the unit in places such as:
In places where a mineral oil mist, spray or vapour may be present in the
atmosphere. Plastic parts may deteriorate and fall off or cause water leakage.
Sound sensitive areas (e.g. near a bedroom), so that the operation noise will
cause no trouble.
In places with high humidity (max. RH=85%), for example a bathroom.
In places where frost is possible. Ambient temperature around the indoor unit
must be >5°C.
NOTICE
When the temperature in multiple rooms is controlled by 1 thermostat, do NOT
place a thermostatic valve on the emitter in the room where the thermostat is
installed.
At certain times, you have to open the unit. Example:
When connecting the electrical wiring
When maintaining or servicing the unit
≥600
(mm)
"6.4.4  To connect the drain hose to the drain" 
10 m
50 m
https://
4
[
  59]. It requires to
EPRA14~18DAV3+W1 + ETVZ16S18+23DA6V+9W
Daikin Altherma 3 H HT F
4P587503-1 – 2019.07
(a)