Position Of Switches Before Delivery - Haier AU96NFTAHA Service Manual

Hide thumbs Also See for AU96NFTAHA:
Table of Contents

13. Position of switches before delivery

Number of SW
Function
Number setting
SW01
of indoor unit
Address setting of
SW02
central control
No.1,2 Temperature
compensation of
room temperature
control
SW03
No.3
Not used
Setting of emergency
SW04
running
SW05
Setting of indoor HP
A i r f l o w
compensation
SW06
(only for cassette)
SW07
Content of function
Setting in group running control
0: master unit 1~15: slave unit
No.7: ON, remote controller can not set address
No.7: OFF, remote controller can set address
For content of address setting, refer to the
following page
Temperature compensation of room temperature
when heat running
No.1/2
ON/ON ON/OFF OFF/ON OFF/OFF
Control
+0*
temperature
No.3 In the state of OFF
ON
emergency running
OFF
Normal running
Have been set before delivery
For content of setting, refer to the
following page
r a t e
When installing height exceeds 2.7 m,
No.1, No.2 setting is on the ON side
No.3 not used
After running for 29 minutes, change into
No.1: ON
rated power running
No.1: OFF usual
No.2: OFF Heat pump
No.2: ON
Cooling only
105
+2*
+4*
+6*
: http://splitoff.ru/tehn-doc.html
Position when delivery
ON
1
2
3
4
5
6
7
ON
1
2
3
ON
OFF
ON
1
2
3
4
ON
1
2
3
ON
1
2