Honeywell HE240 Installation Instructions Manual page 6

Table of Contents
Available languages

Available languages

HE240, HE280 HUMIDIFIER AND INSTALLATION KIT
Selecting Location for Humidistat
• Select a location for the humidistat on the return plenum or on the wall in the
living space.
• Mounting on the return plenum is the easiest installation for the control wiring
circuit.
IMPORTANT
The humidistat must be mounted upstream from the humidifier or bypass duct to
ensure it is properly sensing the relative humidity of the living space. Locate the
control at least 8 in. (203 mm) upstream from the humidifier in the return air duct.
(See Fig. 3.)
Locating Closest 120 V Electrical Outlet
• Select location with access to an outlet. If not available, contact an electrician to
have one installed.
• Make sure that the 20 ft (6.2 m) of thermostat wire is adequate to reach from the
humidifier to the humidistat, and also from the humidifier to the transformer.
Please note that the thermostat wire will need to be cut into the 2 correct lengths.
See "Wiring" on page 14 for more information.
69-2685ES—01
Fig. 2. Typical humidifier installation locations.
RETURN
AIR
6 in. (152 mm)
MINIMUM
BEST
LOCATION
RETURN AIR DUCT
Fig. 3. Selecting duct location for humidistat.
CHOOSE A LOCATION IN A CONDITIONED
SPACE THAT HAS ACCESS TO A WATER SUPPLY
PIPE. COLD OR HOT WATER CAN BE USED.
SELECT A SURFACE ON THE HVAC SUPPLY OR
RETURN DUCT WITH CLEARANCE FOR THE
SOLENOID VALVE, DRAIN LINE AND COVER
REMOVAL.
LOCATION MUST ALSO HAVE ACCESS TO 120
VAC POWER.
ENSURE THE LOCATION IS NEAR A DRAIN.
CONSULT LOCAL PLUMBING CODES FOR
PROPER DRAINAGE.
ALTERNATE LOCATION
15 in. (381 mm)
MINIMUM
6
RETURN
AIR
M12831
M33410