Fans; Replacing The R1I And R2I Module Cooling Fan - ABB ACS880-204 Hardware Manual

Igbt supply module
Hide thumbs Also See for ACS880-204:
Table of Contents

Fans

The lifespan of the cooling fans of the drive depends on the running time, ambient
temperature and dust concentration. See the firmware manual for the actual signal which
indicates the running time of the cooling fan. Reset the running time signal after fan
replacement.
Replacement fans are available from ABB. Do not use other than ABB specified spare parts.

Replacing the R1i and R2i module cooling fan

WARNING!
Read the safety instructions given in Safety instructions for ACS880
multidrive cabinets and modules (3AUA0000102301 [English]). If you
ignore them, injury or death, or damage to the equipment can occur.
1. Stop the drive and do the steps in section
you start the work.
2. Detach the power cable clamp plate and terminal blocks.
3. Release the retaining clips (arrowed) carefully using a screwdriver.
4. Pull the fan holder out.
5. Disconnect the fan cable.
6. Carefully bend the clips on the fan holder to free the fan.
7. Install new fan in reverse order.
Note:
The airflow direction is bottom-to-top. Install the fan so that the arrow on it points up.
In the drawing, the direction of airflow is from right to left.
Electrical safety precautions (page 112)
Maintenance 161
before

Hide quick links:

Table of Contents
loading

Table of Contents