Editing Preset Names; Settings - Philips Selecon PLPROFILE4 Installation & User Manual

Led luminaries
Hide thumbs Also See for Selecon PLPROFILE4:
Table of Contents
PLPROFILE4 LED Luminaires
Note: If the Color Mix of a Factory Calibrated Preset is changed, by turning protection Off, an '*' is appended to the
end of the Preset's Name to indicate that the Calibrated values have been changed.

Editing Preset Names

On the Edit Preset screen, the option is available to edit the name of a preset, via Screen button. However, the names
of Presets 0-4 cannot be edited.
Use the [LEFT ARROW] and [RIGHT ARROW] keys to select the character to be changed and use the [UP
ARROW] and [DOWN ARROW] keys to change that character. The Character Scroll order is A-Z, space, 0-9. If you
are scrolling up the Alpha character displays as Upper Case; if you are scrolling down the Alpha character displays as
Lower Case. Stop on the character you want, ignoring case, then press the opposite [UP ARROW] or [DOWN
ARROW] key if you want to change the case. [OK] to save changes, [ESC] to cancel changes.

5. Settings

The following Parameters can be changed on the Settings Screen.
The first column "Security Level" is the minimum security level you have to be at before the line is displayed for
editing in the Settings screen.
To edit a value on the Setting Screen, use the [UP ARROW] or [DOWN ARROW] keys to move the highlight to the
settings value you wish to change. Press [OK] to begin editing that value. Use the [UP ARROW], [DOWN
ARROW], [LEFT ARROW] or [RIGHT ARROW] keys to make changes to the value. Press [OK] when complete to
save changes, or [ESC] to cancel changes to that value.
When done making changes on the Settings Screen press [ESC] to re-boot fixture and implement changes. Fixture
will not re-boot if nothing was changed.
Security Level
Security
1
3
3
3
3
General
1
3
Parameter
Enter
4-Digits (0 to 9)
PassPIN
Level 1 PIN
4-Digits (0 to 9)
Level 2 PIN
4-Digits (0 to 9)
Level 3 PIN
4-Digits (0 to 9)
Power-Up
1 - 3 or Locked
Off, Scratch Pad,
Warm White, Cool
Power-Up
White, Day Light,
Preset30, Preset31,
Reset Hours
Values
Default
****
1111
2222
3333
3
Cool White
Last Set
No, Yes
No
Installation & User's Manual
Description
There are 4 levels of security, this allows
you to change the level while in the
Settings Screen.
Sets Level 1 PassPIN
Sets Level 2 PassPIN
Sets Level 3 PassPIN
Security Level after Power-Up, if not
Locked (Level 0)
When the Fixture Powers-Up what does it
output. Scratch Pad is an automatically
saved Preset. Last Set is the last thing
coming out of the fixture, this could be
Warm White with the intensity changed
from that of the Preset.
Resets luminaire's operational hours.
Settings
23