Siemens SIMATIC Ident Compact Operating Instructions
Siemens SIMATIC Ident Compact Operating Instructions

Siemens SIMATIC Ident Compact Operating Instructions

Code reader systems
Hide thumbs Also See for SIMATIC Ident:

Quick Links

SIMATIC Ident
Code Reader Systems
SIMATIC MV420 / SIMATIC MV440
Compact Operating Instructions
Edition
04/2013
Answers for industry.
loading

Summary of Contents for Siemens SIMATIC Ident

  • Page 1 SIMATIC Ident Code Reader Systems SIMATIC MV420 / SIMATIC MV440 Compact Operating Instructions Edition 04/2013 Answers for industry.
  • Page 3: Legal Information

    WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Security Messages

    Security messages Note For its automation and drives product portfolio, Siemens provides IT security mechanisms to support secure operation of the plant/machine. Our products are continuously being further developed also taking into account the aspect of IT security. We therefore recommend that you regularly check for updates of our products and that you only use the latest versions. You will find information on this topic under: Industrial Security (http://www.siemens.com/industrialsecurity)
  • Page 5: Installation

    Installation Installing SIMATIC MV420/SIMATIC MV440 These readers are compact standalone devices that, when mounted in a suitable location, need only be equipped with a lens, a power supply cable, and a communications link. The SIMATIC MV440 reader has four threaded holes (SIMATIC MV420: two threaded holes) each on the front and back, which allows flexible mounting.
  • Page 6 Connecting Connect the reader to the components of your application. ① Combined cable socket for the power supply, I/O connectors, ASM and RS-232 ② Ethernet socket ③ Combined socket for the power supply, I/O terminals, and RS-232 ④ ASM socket ⑤...
  • Page 7 Pinout of Power IO RS-232 cable NOTICE INPUT - COMMON or OUTPUT - COMMON must be connected To be able to use the inputs and outputs described below, it is imperative that the INPUT - COMMON or OUTPUT - COMMON is connected. Table 3-1 SIMATIC MV440 Color...
  • Page 8 Table 3-2 SIMATIC MV420 Color Signal name Possible values Default setting Meaning 24 V DC Power supply Blue Power supply violet INPUT1 Trigger input yellow OUTPUT2 IN_OP, TRD, RDY, READ, MATCH, Freely selectable output. N_OK, EXT_1, EXT_2, EXT_3, EXT_4 Gray/ OUTPUT3 IN_OP, TRD, RDY, READ, MATCH, READ...
  • Page 9 ASM cable The connectors are already fitted to the ASM cable. ● You connect the communication modules, for example RF180C and ASM456, using the ASM cable. For SIMATIC MV420, a special ASM cable with M16 socket is available. The follow cable assignment is defined for connecting to the ASM 475 module: ①...
  • Page 10 ● You will find the Primary Setup Tool (PST): – In your SIMATIC installation – On the product CD of the reader – As a free download on the SIMATIC Support Internet pages (http://support.automation.siemens.com/WW/view/en/19440762). Steps for initial commissioning Step Activity Connect the reader and PC using an Ethernet cable.
  • Page 11 Step 1 Connect the reader and PC using an Ethernet cable Connect the reader directly to your PC/programming device over an Ethernet cable. Note You do not need a crossover cable because the reader is capable of autocrossing and automatically detects the type of cable you are using.
  • Page 12 5. Select "Assign IP parameters" and enter the values for the IP address and subnet mask as shown below. Note IP address 192.168.100.100 ● Using the IP address 192.168.100.100, the reader is configured as a DHCP server at the same time, which means that a connected PC can obtain an IP address from the reader.
  • Page 13 7. Confirm the following message by clicking the "Yes" button. Result The reader now has the manually assigned IP address 192.168.0.34 and can be reached under this address by your PC. Note Depending on the mode being used, you may need to restart the reader by turning the power off and on again. Step 4 Starting the user interface 1.
  • Page 14 4. This is followed by the Adjustment page of the user interface in the Internet Explorer. Result ● You are now connected to the reader and can operate it via the user interface. ● You can now perform the next step and adjust the reader and display the first read results. ●...
  • Page 15 Step 5 Aligning the reader Before you put the reader into productive operation, you must first align it correctly. You do this with the user interface by selecting the "Adjust sensor" menu command. The dialog window shows you an image as seen by the reader. Note Focusing the image (SIMATIC MV440 only) To be able to focus the image, you may need to loosen the fixing screws on the lenses.
  • Page 16 2. If necessary, correct these settings: – The exposure settings – If you wish to read an EAN13 code instead of a data matrix code, for example, press the button "Recognize code". The reader starts code type recognition and remembers the code type found for later read processes. –...
  • Page 17 ● Internet: Online support request form: (http://www.siemens.com/automation/support-request) Trademarks All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
  • Page 18 Get more information www.siemens.com/simatic-ident Siemens AG Subject to change without prior notice Industry Sector A5E02370910-06 Sensors and Communication © Siemens AG 2009-2013 P.O. Box 48 48 90026 Nürnberg Industrielle GERMANY Schalttechnik SIRIUS www.siemens.com/automation...

This manual is also suitable for:

Simatic mv420Simatic mv440