Branch Provider (BP) Unit
2. Branch Provider (BP) Unit
2.1
BPMKS048A2U, BPMKS049A3U
PCB Detail
1) X20A
2) X21A - X23A
3) X90A
4) F2U
5) X3M
6) X4M
7) X5M
8) F1, F2 (on X6M)
9) L1, L2 (on X1M)
10)E1
11)H1P (LED A)
12)H2P - H5P
13)DS2
Note:
X23A and X5M are not used for BPMKS048A2U.
X3M
X4M
X5M
17
Connector for bypass electronic expansion valve
Connector for electronic expansion valve for room A, B, C
Connector for thermistors
Fuse (3.15 A / 250 V)
Terminal for inter-connecting wire to room A
Terminal for inter-connecting wire to room B
Terminal for inter-connecting wire to room C
Terminal for transmission to outdoor unit or other BP units
Terminal for power supply (60 Hz, 208 ~ 230 V)
Terminal for ground
LED for service monitor (green)
LED for error indication (red)
(LED 1 - 4)
Dip switch
DS2
X90A
H1P (LED A)
H2P (LED 1)
H3P (LED 2)
H4P (LED 3)
H5P (LED 4)
F2U
E1
Printed Circuit Board Connector Wiring Diagram
SiUS181305E
X23A
X22A
X21A
X20A
F2
X6M
F1
L2
X1M
L1
3P326842-1
3P326842-2