Duration Prompt; Log Time Prompt; Time Increment Prompt - GE DigitalFlow GS868 Programming Manual

Panametrics steam ultrasonic mass flowmeter, 2-channel
Hide thumbs Also See for DigitalFlow GS868:
Table of Contents
END DATE Prompt

DURATION Prompt

LOG TIME Prompt

TIME INCREMENT Prompt

Logging Data
13.Press
[F1]
to accept the displayed end date or press
different end date. To end the log today, press
OK
TODAY
If
or
was selected, proceed to the
prompt. Refer to Figure A-7 on page A-7 for a flow diagram of
the programming sequences.
Otherwise, complete the steps below.
a. Enter the desired Year and press
0 to 99.
b. Use the [←], [→] and
Month.
c. Enter the desired Day and press
1 to the number of days in the selected month (28, 29, 30 or
31). The program proceeds to step 15.
If a circular log was specified, the programming sequence continues
here after the log start time and/or start date is entered.
14.Press
[F1]
and enter a log duration in hours or press
log duration in days. When the desired value has been entered,
[ENT]
press
. The program proceeds to step 16.
TIMED
If
was selected at step 12, the programming sequence continues
here.
15.Use the [←], [→] and
duration.The available options are: 10min, 30min, 60min, 3 HR, 6
HR, 12 HR and 24 HR.
Regardless of which of the various options were selected during the
previous programming steps, all of the paths converge at this point.
16.Use the [←], [→] and
Increment. The available options are: 5sec, 10sec, 30sec, 1min,
3min, 6min, 12min, 30min and 60 min.
The time increment is the frequency at which the Model GS868 takes
and records data measurements. If any reading takes longer than the
programmed time increment, the log is filled in with the next
consecutive reading. For example, assume that a velocity value of 3
ft/sec is recorded at 12:00:00 in a log with a time increment of five
seconds. If the next reading is 8 ft/sec and it takes the meter 12
seconds to read this value, then both of the missed readings (12:00:05
and 12:00:10) will be filled in with the 8 ft/sec value.
[F3]
TIME INCREMENT
[ENT]
. The acceptable range is
[F1]-[F4]
keys to select the desired
[ENT]
. The acceptable range is
[F1]-[F4]
keys to select the desired log
[F1]-[F4]
keys to select the desired Time
March 2008
[F2]
to enter a
.
[F2]
and enter a
3-5
Table of Contents