Slant/Fin B-120A User's Information Manual

Slant/Fin B-120A User's Information Manual

Residential • gas fired • hot water boilers direct-vent sealed combustion condensing boiler

Quick Links

User's Information Manual
Bobcat Direct-Vent Sealed Combustion Condensing Boiler
• Before operating this boiler, READ this manual.
• DO NOT attempt to install, service or repair this boiler yourself. There are no user serviceable
parts. Contact a qualified service agency if your boiler needs repair or maintenance. Ask your gas supplier for a
list of qualified service agencies.
• A qualified service agency should inspect the venting system of this boiler on an annual basis.
Your gas boiler must be installed and serviced by a qualified service agency or gas
supplier. The lack of proper service can result in a dangerous condition.
This manual must be left with owner, hung on or
adjacent to the boiler. Owner should retain manual
for future reference.
Residential • Gas fired • Hot Water Boilers
Model B-120A and B-200A
FOR YOUR SAFETY:
Printed in U.S.A. 808
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result
causing property damage, personal injury or loss
of life.
__
DO NOT store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
__
WHAT TO DO IF YOU SMELL GAS
• DO NOT try to light any appliance.
• DO NOT touch any electrical switch
• DO NOT use any phone in your
building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
__
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Part No. 86-5757000
Publication No. BA-UIM
Table of Contents
loading

Summary of Contents for Slant/Fin B-120A

  • Page 1 • DO NOT attempt to install, service or repair this boiler yourself. There are no user serviceable parts. Contact a qualified service agency if your boiler needs repair or maintenance. Ask your gas supplier for a list of qualified service agencies.
  • Page 2: Lighting Instructions

    Figure 1. Location and identification of parts. (model 120A shown) WELCOME TO OUR VALUED CUSTOMER You are now the owner of a Slant/Fin Bobcat series gas-fired boiler, another quality heating product designed and manu- factured by an industry leader, to provide your family with many years of reliable comfort and trouble-free performance.
  • Page 3 VENT PIPE 3” DIA. AIR INTAKE PIPE Figure 2. Direct vent, sidewall venting illustration. Bobcat Model B-120A and B-200A 1. VENTING AND AIR INTAKE SYSTEM REGULAR INSPECTION Inspect the system regularly for condensation, corrosion, sagging and/or physical damage. A qualified professional should service the boiler annually and include such an inspection at that time.
  • Page 4 Bobcat Model B-120A and B-200A 3 IN. DIA. VENT PIPE Figure 4. Non-direct vent, sidewall venting. AIR INTAKE (DO NOT BLOCK) VENT TERMINATION OUTSIDE WALL...
  • Page 5 Figure 5. Non-direct vent, venting through the roof. Figure 6. Non-direct vent, utilizing an existing chimney as a chase. Bobcat Model B-120A and B-200A VENT TERMINATION 3 IN. DIA. VENT PIPE AIR INTAKE (DO NOT BLOCK) VENT TERMINATION CHIMNEY TOP PLATE...
  • Page 6: Condensate Removal System

    Bobcat Model B-120A and B-200A CONDENSATE TRAP, FILLED WITH WATER Figure 7. Condensate disposal system 2. CONDENSATE REMOVAL SYSTEM The Bobcat B-120 and B-200 boilers are equipped with a built-in condensation drain and trap. The trap must be filled with water. DO NOT operate the boiler without fill- ing the trap with water to prevent flue gas discharge into space.
  • Page 7: Safety Information

    • If you cannot reach your gas supplier, call the fire department. Bobcat Model B-120A and B-200A C. Use only your hand to turn the gas supply shut off valve. Never use tools. If the supply shut off will not turn by hand, don’t try to repair it, call a qualified service...
  • Page 8: Integrated Boiler Control

    Bobcat Model B-120A and B-200A Removing Jacket Front Panel 1. Turn black screws ⁄ turn to open position. 2. Remove front panel. To replace the panel, reverse procedure. INTEGRATED BOILER CONTROL The integrated boiler control monitors the status of the...
  • Page 9 Blinking dot on “Mode Display” indicates active heating control, burner off. Steady dot indicates burner is on. *: Error must be corrected to resume boiler operation. Pressing the “Reset” button is not required. **: The boiler circulator is energized, when boiler water temperature drops below 50˚F.
  • Page 10 Bobcat Model B-120A and B-200A Table 2: Viewing and Changing Temperatures Press “Select” button for viewing different modes on “Mode Display” Mode Table 1 Table 2 Display Table 1 Table 2 Table 1 Table 2 Blinking Blinking Table 1 Table 1...
  • Page 11 Indicated by an “E” in the mode display. Operation is automatically restored, once the condition returns to normal or is fixed. The temperature display shows the error code. Pressing the “Reset” button is not required. Bobcat Model B-120A and B-200A ERROR INDICATION CODE Water Outlet Sensor Open...
  • Page 12 ©Slant/Fin Corp. 2008 SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600 FAX: (516) 484-5921 • Canada: Slant/Fin , Mississauga, Ontario LTD/LTEE www.slantfin.com...

This manual is also suitable for:

B-200aBobcat b-200a

Table of Contents