Masoneilan* spring diaphragm and differential pressure actuators for use with 500 series regulators

Quick Links

GE Oil & Gas
10900
Series
Masoneilan* Spring Diaphragm and
Differential Pressure Actuators for use
with 500 Series Regulators
Instruction Manual
GE Data Classification : Public
loading

Summary of Contents for GE 10900 Series

  • Page 1 GE Oil & Gas 10900 Series Masoneilan* Spring Diaphragm and Differential Pressure Actuators for use with 500 Series Regulators Instruction Manual GE Data Classification : Public...
  • Page 2 SPECIFIC REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR’S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, GE (GENERAL ELECTRIC COMPANY AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE TYPE OF EQUIPMENT PROVIDED.
  • Page 3: Safety Information

    Read the instructions carefully before installing and • These instructions are written specifically for the maintaining your control valve. DANGER and WARNING Masoneilan 10900 Series actuators, and do not apply to hazards are related to personal injury. CAUTION hazards other equipment outside of this product line.
  • Page 4: Description-Operation

    The 10900 Series Actuators are designed for use with the 500 For installation, operation, adjustment and maintenance of the Series Regulators for reducing, back pressure and differential 500 Series Regulators body S/A refer to instructions numbers pressure applications.
  • Page 5 Only on 0.5-2 ; 1.5-3 ; 2-10 ; 6-20 and 15-40 psi ranges actuators mounted on types 526 and 536H Only on 0.5-2 ; 1.5-3 ; 2-10 ; 6-20 and 15-40 psi ranges regulators Only on 150-750 psi range © 2015 General Electric Company. All rights reserved. Masoneilan 10900 Series Actuator Instruction Manual | 5...
  • Page 6: Installation

    In the Spring Diaphragm Actuators, the 1/2” NPT pressure Refer to Regulators Body S/A Instructions for installation connection is located on the upper diaphragm case (13). according to the regulator function. 6 | GE Oil & Gas © 2015 General Electric Company. All rights reserved.
  • Page 7: Maintenance

    Note: By means of a wrench applied on the plug stem nuts, hold the actuator stem during this operation. Uniformly tighten all diaphragm case nuts (16) when reassembling. © 2015 General Electric Company. All rights reserved. Masoneilan 10900 Series Actuator Instruction Manual | 7...
  • Page 8 DISTRIBUTOR E.P. & S. - FRANCE 24 bis rue de Picpus 75012 PARIS Tel: +33 (0) 762 682 291 Tel: +33 (0) 650 590 965 [email protected] E.P. & S. - CAMEROON Immeuble Carré d’Or Rue Soppo Priso Côté Chococho, Bonapriso DOUALA Tel: +237 6 52 12 70 95 Tel: +33 (0) 782 006 276...