Allen-Bradley POINT I/O 1734-4IOL Installation Instructions Manual
Allen-Bradley POINT I/O 1734-4IOL Installation Instructions Manual

Allen-Bradley POINT I/O 1734-4IOL Installation Instructions Manual

4 channel io-link master module
Hide thumbs Also See for POINT I/O 1734-4IOL:
Table of Contents
loading

Summary of Contents for Allen-Bradley POINT I/O 1734-4IOL

  • Page 1: Table Of Contents

    Installation Instructions Original Instructions POINT I/O 4 Channel IO-Link Master Module Catalog Number 1734-4IOL Topic Page Important User Information Environment and Enclosure Prevent Electrostatic Discharge Special Conditions for Safe Use About the Module Install the Mounting Base Install the Module Install the Removable Terminal Block Remove a Mounting Base Wire the Module...
  • Page 2: Important User Information

    POINT I/O 4 Channel IO-Link Master Module Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid-state Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid- state equipment and hard-wired electromechanical devices.
  • Page 3: Environment And Enclosure

    POINT I/O 4 Channel IO-Link Master Module Environment and Enclosure ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in EN/IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such environments.
  • Page 4: Prevent Electrostatic Discharge

    POINT I/O 4 Channel IO-Link Master Module Prevent Electrostatic Discharge ATTENTION: This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: • Touch a grounded object to discharge potential static. •...
  • Page 5: Special Conditions For Safe Use

    POINT I/O 4 Channel IO-Link Master Module Special Conditions for Safe Use ATTENTION: • This product is grounded through the DIN rail to chassis ground. Use zinc plated chromate-passivated steel DIN rail to assure proper grounding. The use of other DIN rail materials (for example, aluminum or plastic) that can corrode, oxidize, or are poor conductors, can result in improper or intermittent grounding.
  • Page 6: About The Module

    POINT I/O 4 Channel IO-Link Master Module About the Module The POINT I/O 4 Channel IO-Link Master Module provides four channels that can be individually configured as IO-Link master or as a standard digital I/ O module. The IO-Link channel master module can be configured to fit any IO-Link and/or discrete application.
  • Page 7 POINT I/O 4 Channel IO-Link Master Module POINT I/O 4 Channel IO-Link Master Module with 1734-TB, 1734-TBS, 1734-TB3, or 1734- TB3S Wiring Base Assembly The 1734-TB, 1734-TBS, 1734-TB3, or 1734-TB3S wiring base assembly consists of a 1734-MB mounting base and a 1734-RTB or 1734-RTBS 46012 removable terminal block.
  • Page 8 POINT I/O 4 Channel IO-Link Master Module POINT I/O 4 Channel IO-Link Master Module with 1734-TOP, 1734-TOPS, 1734-TOP3, or 1734-TOP3S One-piece Terminal Base 46013 Description Description Module locking mechanism Interlocking side pieces Slide-in writable label Mechanical keying (orange) Insertable I/O module DIN rail locking screw (orange) Terminal block handle Module wiring diagram...
  • Page 9: Install The Mounting Base

    POINT I/O 4 Channel IO-Link Master Module Install the Mounting Base To install the mounting base on the DIN rail, proceed as follows: 1. Position the mounting base vertically above the installed units (adapter, power supply, or existing module). Slide the mounting base until the interlocking side pieces engage the adjacent module or adapter.
  • Page 10 POINT I/O 4 Channel IO-Link Master Module base. In addition, make sure that the mounting base locking screw is positioned horizontal referenced to the base. 1734-TB Base 1734-TOP Base Be sure the DIN rail locking Turn the keyswitch to align screw is in the horizontal the number with the position.
  • Page 11: Install The Removable Terminal Block

    POINT I/O 4 Channel IO-Link Master Module 4. Press to secure. The module locks into place. 44013 Install the Removable Terminal Block A Removable Terminal Block (RTB) is supplied with your wiring base assembly. To remove, pull up on the RTB handle. This allows the mounting base to be removed and replaced as necessary without removing any of the wirings.
  • Page 12 POINT I/O 4 Channel IO-Link Master Module 3. If an I/O module is installed, snap the RTB handle into place on the module. Hook the RTB end into the mounting base end, and rotate until it locks into place. 44012 WARNING: For 1734-RTBS and 1734-RTB3S, to latch and unlatch the wire, insert a bladed screwdriver (catalog number 1492-N90 –...
  • Page 13: Remove A Mounting Base

    POINT I/O 4 Channel IO-Link Master Module WARNING: For 1734-TOPS and 1734-TOP3S, to latch and unlatch the wire, insert a bladed screwdriver (catalog number 1492-N90 – 3 mm diameter) into the opening at approximately 97° (blade surface is parallel with top surface of the opening) and press in (do not push up or down).
  • Page 14: Wire The Module

    POINT I/O 4 Channel IO-Link Master Module Wire the Module To wire the module, refer to the diagrams and tables. POINT I/O 4 Channel IO-Link Master Module – 1734-4IOL 1734-4IOL Channel 0 Channel 1 Channel 2 Channel 3 POINT I/O 4 Channel IO-Link Master Module Wiring - IO-Link Mode Ch 0 Ch 1 3-wire...
  • Page 15 POINT I/O 4 Channel IO-Link Master Module POINT I/O 4 Channel IO-Link Master Module Wiring – Standard Digital Input Mode In 0 In 1 2-wire 3-wire 3-wire 2-wire In 2 In 3 In = Input channel C = Common V = Voltage Channel Input Common...
  • Page 16: Communicate With The Module

    POINT I/O 4 Channel IO-Link Master Module Channel Output Common Voltage Channel 2 Channel 3 Connect voltage on 3-wire outputs. Power is supplied through the internal power bus. Communicate with the Module POINT I/O™ modules send (produce) and receive (consume) I/O data (messages).
  • Page 17 POINT I/O 4 Channel IO-Link Master Module Default Data Map for 1734-4IOL – Configuration Assembly Instance 100 Message Size: 46 Bytes Consumed Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Channel 3 input off to on time delay Channel 3 input on to off time delay (1) Fault and idle conditions are only valid when the channel is configured for IO-Link or DO.
  • Page 18: Interpret Status Indicators

    POINT I/O 4 Channel IO-Link Master Module Default Data Map for 1734-4IOL – Produced Assembly Instance 102 Message Size: 0...132 Bytes Consumed Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 b+1...c Input data from Channel 2 c+1...d Input data from Channel 3...
  • Page 19 POINT I/O 4 Channel IO-Link Master Module Indicator Status for Modules Status Description No power applied to device. Green Device operating normally. Flashing green The device has not been configured. Module status Flashing red Recoverable fault. One or more non-recoverable major faults detected. Flashing red/green Device is self-testing.
  • Page 20: Specifications

    POINT I/O 4 Channel IO-Link Master Module Specifications General Specifications Attribute Value Number of inputs 4 single-ended, non-mutual isolated, configurable Number of outputs Communication rate, IO-Link 4.8 kB; 38.4 kB; 230.4 kB Device cable length, IO-Link, max 20 m (65.6 ft) Terminal base screw torque 0.8 N•m (7 lb-in.) 1734-TB, 1734-TBS, 1734-TB3, 1734-TB3S, 1734-TOP, 1734-TOPS, 1734-...
  • Page 21 POINT I/O 4 Channel IO-Link Master Module General Specifications Attribute Value 56 x 12 x 75.5 mm Dimensions, approx., HxWxD (2.21 x 0.47 x 2.97 in.) Weight, approx. 36 g (1.27 oz) Enclosure type rating None (open-style) Keyswitch position (1) Use this Conductor Category information for planning conductor routing as described in the appropriate System Level Installation Manual.
  • Page 22 POINT I/O 4 Channel IO-Link Master Module POINT I/O 4 Channel IO-Link Master Module 1734-4IOL – Standard Digital Output Attribute Value On-state voltage, nom 24V DC On-state voltage drop, max 0.9V DC On-state current, max 150 mA Off-state current leakage, max 0.5 mA Module current (all outputs), max 600 mA...
  • Page 23 POINT I/O 4 Channel IO-Link Master Module Environmental Specifications Attribute Value IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz Radiated RF immunity 10V/m with 200 Hz 50% pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% pulse 100% AM at 1890 MHz 10V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz IEC 61000-4-4: ±2 kV at 5 kHz on power ports...
  • Page 24 POINT I/O 4 Channel IO-Link Master Module Notes: Rockwell Automation Publication 1734-IN043B-EN-E - January 2019...
  • Page 25 POINT I/O 4 Channel IO-Link Master Module Notes: Rockwell Automation Publication 1734-IN043B-EN-E - January 2019...
  • Page 26 POINT I/O 4 Channel IO-Link Master Module Notes: Rockwell Automation Publication 1734-IN043B-EN-E - January 2019...
  • Page 27 POINT I/O 4 Channel IO-Link Master Module Rockwell Automation Support Use the following resources to access support information. Knowledgebase Articles, How-to Videos, Technical Support www.rockwellautomation.com/ FAQs, Chat, User Forums, and Product knowledgebase Center Notification Updates. Local Technical www.rockwellautomation.com/global/ Support Phone Locate the phone number for your country.
  • Page 28 Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, POINT I/O, Rockwell Automation, Rockwell Software, RSLogix 5000, Studio 5000 and TechConnect are trademarks of Rockwell Automation, Inc. EtherNet/IP is a trademark of ODVA, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.

Table of Contents