Other Control; Heating Operation Prohibition; Inverter Fan Control (Switch Box Fan); Crankcase Heater - Daikin ALTHERMA HT Service Manual

Hide thumbs Also See for ALTHERMA HT:
Table of Contents
ESIE09-08B

5. Other Control

Heating Operation Prohibition

5.1
 If the ambient temperature becomes higher than (24°C + value of setting [9-02]) no space
 Heating for domestic hot water is possible till 35°C ambient temperature.
For more details see chapter of settings.
5.2

Inverter Fan Control (Switch Box Fan)

5.3

Crankcase Heater

Function
heating is possible
Compressor ON
Tfin>50°C
Cooling fan OFF
Tfin<30°C
Compressor OFF
Tdi error
OR
AND
Crankcase heater OFF
OR
Cooling fan ON
Compressor OFF
Tdi<70°C
Crankcase heater ON
Tdi>75°C
Compressor ON

Other Control

61