Voltage - Panasonic KW8M User Manual

Eco-power meter
Hide thumbs Also See for KW8M:
Table of Contents
・Current measurement parts
Eco-POWER METER measures the current as below.
Display
System
Single-phase two-wire
Single-phase three-wire
Three-phase three-wire
Three-phase four-wire

6.1.4 Voltage

・It displays the voltage value of the load.
・Press to change voltage between P1 and P0, P2 and P0, P3 and P0.
*Before start measuring, select phase and wire system according to the measured load.
When 1P3W or 3P3W is selected, it doesn't measure 1P2W system correctly. When 3P4W system is
selected, it doesn't measure 1P2W, 1P3W, 3P3W system correctly.
Select phase and wire system according to the measured system. (Refer to the explanation of setting
mode.)
[V]
Lighting
・When input voltage is under 5% of rating, it displays "0.0" and doesn't measure.
("Under 5%" means the value getting from this calculation
・When input voltage exceeds 150%F.S. at each range, 「- - - -」 will be displayed.
・Voltage measurement parts
Eco-POWER METER measures the voltage as below.
Display
System
Single-phase
Between P1 and P0 (R)
two-wire
Single-phase
three-wire
Three-phase
Between P1 and P0 (R)
three-wire
Three-phase
four-wire
L1
L1(R) current
L1(R) current
L1(R) current
L1(R) current
"rated voltage 200(400) x 0.05 x VT ratio".)
L1 V
voltage(line-voltage)
R voltage
(phase-voltage)
voltage (line-voltage)
R voltage
(phase-voltage)
KW8M Eco-POWER METER (1A/5ACT input type)
L2
(Skip)
L2 (T) current
L2 (T) current
L2 (S) current
L2 V
(Skip)
S voltage
(phase-voltage)
Between P2 and P0 (T)
voltage (line-voltage)
S voltage
(phase-voltage)
30
L3
(Skip)
(Skip)
L3 (S) current
L3 (T) current
L3 V
(Skip)
(Skip)
Between P1 and P2 (S)
voltage (line-voltage)
T voltage
(phase-voltage)
Table of Contents
loading

This manual is also suitable for:

Akw8115

Table of Contents