Dell S4048-ON Configuration Manual

Dell S4048-ON Configuration Manual

Ps series
Hide thumbs Also See for S4048-ON:
Table of Contents
Dell EMC Networking S4048-ON
Switch Configuration Guide for Dell PS Series SANs
Dell EMC Configuration and Deployment Guide
Abstract
This document illustrates how to configure Dell EMC™ Networking
S4048-ON switches for use with Dell™ PS Series storage while using
Dell EMC best practices.
February 2018
Table of Contents
loading

Summary of Contents for Dell S4048-ON

  • Page 1 Switch Configuration Guide for Dell PS Series SANs Abstract This document illustrates how to configure Dell EMC™ Networking S4048-ON switches for use with Dell™ PS Series storage while using Dell EMC best practices. February 2018 Dell EMC Configuration and Deployment Guide...
  • Page 2: Revisions

    Update to include configuration steps for both OS 9.x and 10.x The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose.
  • Page 3: Table Of Contents

    2.3.1 Disable DCB ..............................13 2.3.2 Remove DCB policies and apply standard flow control ................... 14 2.3.3 Revert to default VLAN ID on switch and arrays ....................14 Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 4 3.2.1 Disable iSCSI ..............................22 3.2.2 Disable 802.3x flowcontrol on all ports ......................22 3.2.3 Enable DCB ..............................22 3.2.4 Create tagged VLAN for all ports and port-channels ..................23 Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 5 3.3.9 Reload ................................29 3.3.10 Verify DCB status ............................29 3.3.11 Configure additional switch .......................... 29 Technical support and resources ..........................30 Related resources ............................30 Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 6: Introduction

    Introduction Introduction This document illustrates how to configure Dell EMC™ Networking S4048-ON switches for use with Dell™ PS Series storage while using Dell EMC best practices. The recommended configuration uses Link Aggregation Groups (LAGs) for inter-switch connections. The host servers and storage controllers can be connected to the switches using the 40GbE Quad Small Form-factor Pluggable (QSFP) ports with appropriate breakout cables.
  • Page 7: Cabling Diagram

    Introduction Cabling diagram The cabling diagram in Figure 1 represents the Dell EMC recommended method for deploying servers and PS Series arrays. Cabling diagram Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 8: Switch Configuration (Os 9.X)

    Note: Firmware downloads and documentation can be found at Dell.com/support. Dell EMC recommended switch configuration The steps in this section show how to configure two S4048-ON switches with a Link Aggregation Group (LAG). The switches are interconnected using two of the 40GbE Quad Small Form-factor Pluggable (QSFP) uplink ports, and the LAG is configured for Dynamic Link Aggregation Control Protocol (LACP).
  • Page 9: Delete Startup Configuration

    The prior example assumes a class C subnet mask. 2.1.5 Configure login credentials Dell(conf)#username admin privilege 15 password 0 Dell(conf)#enable password level 15 0 Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 10: Enable Switch Ports

    Dell(conf)# protocol spanning-tree rstp Dell(conf-rstp)#no disable Dell(conf-rstp)#exit 2.1.10 Configure port channel for LAG Configure the switch interconnect as a LAG. Dell(conf)#interface Port-channel 1 Dell(conf-if-po-1)#mtu 12000 Dell(conf-if-po-1)#switchport Dell(conf-if-po-1)#no shutdown Dell(conf-if-po-1)#exit Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 11: Configure Qsfp Ports For Lag

    Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in a non-default VLAN, refer to the documentation for your switch. Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 12: Configure Data Center Bridging (Dcb) (Optional)

    Switch configuration (OS 9.x) Configure Data Center Bridging (DCB) (optional) Use the following commands to enable DCB mode on the switch. Note: You must complete the Dell EMC recommended switch configuration steps in section 2.1 before configuring the switch for DCB mode. 2.2.1 Disable 802.3x flowcontrol on SFP+ ports...
  • Page 13: Configure Dcb Policies

    Power off all arrays and hosts connected to the SAN before proceeding with these steps. 2.3.1 Disable DCB Dell#configure Dell(conf)#no dcb enable Dell(conf)#exit Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 14: Remove Dcb Policies And Apply Standard Flow Control

    Verify DCB status Dell#show dcb DCB Status : Disabled 2.3.7 Configure additional switch Repeat the commands from section 2.3 to disable DCB on any additional switches. Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 15: Optional Stack Configuration

    Dell#delete startup-config Proceed to delete startup-config [confirm yes/no]yes Dell#reload System configuration has been modified. Save? [yes/no]no Proceed with reload [confirm yes/no]yes Note: The switch will reboot. Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 16: Configure Stack On The Second Switch

    is the gateway for the switch. If your management system is on the same subnet as the switch, the previous step may be omitted. The prior example assumes a class C subnet mask. Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 17: Configure Login Credentials

    Note: The preceding procedure places all switch ports in the default VLAN. If you prefer to place ports in a non-default VLAN, refer to the switch documentation. Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 18: Switch Configuration (Os 10.X)

    Switch configuration (OS 10.x) This section provides steps to configure Dell EMC Networking S4048-ON switches running Dell Networking OS 10.x (firmware 10.x). If your switches are running Dell Networking OS 9.x (firmware 9.x), follow the steps in section 2 instead.
  • Page 19: Delete Startup Configuration

    To configure these ports as 4 x 10GbE ports, use the following commands. OS10(config)# interface breakout 1/1/ map 10g-4x OS10(config)# exit OS10# Use the following command to check port interface status. OS10# show interface status Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 20: Enable Switch Ports

    This section describes enabling iSCSI auto-detection of attached storage arrays and switch auto- configuration. PS Series and Dell EMC SC Series storage arrays will be detected by the switch when iscsi is enabled. The switch will auto-configure for Jumbo frames with MTU 9216 and flowcontrol receive on, transmit off for all the ports.
  • Page 21: Enable Jumbo Frames And Flow Control (Optional)

    OS10(config)# interface range ethernet 1/1/49,1/1/50 OS10(conf-range-eth1/1/49,1/1/50)# no switchport OS10(conf-range-eth1/1/49,1/1/50)# channel-group 1 mode active OS10(conf-range-eth1/1/49,1/1/50)# mtu 9216 OS10(conf-range-eth1/1/49,1/1/50)# flowcontrol receive on OS10(conf-range-eth1/1/49,1/1/50)# flowcontrol transmit off OS10(conf-range-eth1/1/49,1/1/50)# exit OS10(config)# exit Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 22: Save Configuration

    VLAN, refer to the switch documentation. Configure Data Center Bridging (DCB) (optional) To enable DCB mode on the switch, use the following commands. Note: You must complete the Dell EMC recommended switch configuration steps in section 3.1 before configuring the switch for DCB mode. 3.2.1...
  • Page 23: Create Tagged Vlan For All Ports And Port-Channels

    OS10(config-pmap-network-qos)# exit OS10(config)# OS10(config)# policy-map type application OS10(config-pmap-application)# class class-iscsi OS10 (config-pmap-c-app)# set qos-group 4 OS10 (config-pmap-c-app)# set cos 4 OS10 (config-pmap-c-app)# exit OS10(config-pmap-application)# exit OS10(config)# Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 24: Configure Ets Policies

    3.2.10 QoS policy OS10(config)# system qos OS10(config-sys-qos)# service-policy input type qos OS10(config-sys-qos)# service-policy type application OS10(config-sys-qos)# ets mode on OS10(config-sys-qos)# exit OS10(config)# Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 25: Apply Policies And Vlan Id To All Switch Edge Ports (Except Port-Channel Member Ports)

    OS10(conf-range-eth1/1/49,1/1/50)# priority-flow-control mode on OS10(conf-range-eth1/1/49,1/1/50)# exit OS10(config)# exit OS10(config)# 3.2.13 iSCSI enable OS10(config)# iscsi enable OS10(config)# iscsi session-monitoring enable OS10(config)# exit 3.2.14 Save configuration OS10# copy running-configuration startup-configuration Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 26: Show Commands To Verify Dcbx, Ets, And Pfc Status On Individual Ports

    OS10# show lldp dcbx interface ethernet 1/1/ pfc detail OS10# show lldp dcbx interface ethernet 1/1/ ets detail 3.2.16 Configure additional switches Repeat the commands from section 3.2 to configure DCB on additional switches. Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 27: Revert From Dcb To Non-Dcb Configuration (Optional)

    OS10(conf-range-eth1/1/1-1/1/48)# no switchport trunk allowed vlan OS10(conf-range-eth1/1/1-1/1/48)# no switchport mode OS10(conf-range-eth1/1/1-1/1/48)# switchport mode access OS10(conf-range-eth1/1/1-1/1/48)# flowcontrol receive on OS10(conf-range-eth1/1/1-1/1/48)# flowcontrol transmit off OS10(conf-range-eth1/1/1-1/1/48)# exit OS10(config)# Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 28: Remove Dcb Policies And Apply Standard Flow Control On Port-Channel Member Ports

    The previous steps in section 3.3.3 and 3.3.4, revert the switch ports to default native vlan 1. Use the following command to remove VLANs other than vlan 1 from the switch configuration. OS10(config)# no interface vlan Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 29: Remove Ets, Pfc, And Other Policies From Switch Configuration

    Verify DCB status OS10# show lldp dcbx interface ethernet 1/1/ 3.3.11 Configure additional switch Repeat the commands from section 3.3 to disable DCB on any additional switches. Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...
  • Page 30: A Technical Support And Resources

    Dell EMC Storage Compatibility Matrix For PS Series best practices white papers, reference architectures, and sizing guidelines for enterprise applications and SANs, refer to PS Series Technical Documents. Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026...