Planning and Installation
Honeywell
User Guide
Table of Contents
loading

Summary of Contents for Honeywell SC105

  • Page 1 To get the best use of the product, please read the User Guide carefully before using the product.  Keep the User Guide at an easily accessible place and make it available to the next user.  © 2010 Honeywell International Inc. All rights reserved. http://www.security.honeywell.com/ Document 800-04997 Rev. A...
  • Page 3 Honeywell TO THE INSTALLER Before planning and installing Seismic Vibration Detector SC100, the circumstances below should be avoided: Water piping Electrical Devices Do not apply the detectors close to electrical Do not apply the detectors close to water devices (such as electric motors, transformers, piping.
  • Page 4 Seller shall have no obligation under this Limited Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than Honeywell factory service. For warranty service, return product(s) transportation prepaid, to Honeywell Factory Service, 165 Eileen Way, Syosset, New York 11791.
  • Page 5 Honeywell Contents 1 About This Document ............................1 Overview of Contents ..........................1 Special Font and Symbols........................1 How to Use This Document ........................1 2 Introduction ..............................2 Overview of the Detector .........................2 Applications .............................2 Features ..............................3 3 Function Description ............................4 Function Criteria ............................4 Detection Parameters........................4...
  • Page 6 Honeywell Figures Figure 2-1 Detector Description ..............................2 Figure 5-1 Planning ATM Protection............................... 7 Figure 5-2 Planning Vending Machine/Ticket Machine Protection ....................8 Figure 6-1 Opening the Detector ..............................9 Figure 6-2 Drill Plan ..................................9 Figure 6-3 Mounting Plate SC110 - UPSIDE DOWN ........................10 Figure 6-4 Movable Mounting Kit SC111 Components ........................
  • Page 7 Honeywell Tables Table 2-1 Application Settings ................................ 2 Table 9-1 Remote Test ................................. 17...
  • Page 9: About This Document

    The manual has been reviewed and the accuracy is guaranteed. If there is any uncertainty or controversy, please refer to the final explanation of Honeywell. Honeywell does not take any responsibility for any consequences caused by misunderstanding of the manual or improper operations.
  • Page 10: Introduction

    2 Introduction Overview of the Detector Mini-Seismic Vibration Detector SC105 is a seismic or structural vibration detector designed to detect selected vibrations from burglary or intrusion attempts on high value storage units, such as Mini-ATMs, Vending Machines and Ticket Machines.
  • Page 11: Features

    Honeywell Features Mini-Seismic Vibration Detector SC105 has the following features:  24-hour detection of known attack tools on Mini-ATMs, Vending Machines and so on.  Flat frequency non resonant response sensor for genuine frequency analysis.  Built-in diagnostic tool used to set detector sensitivity in relation to existing noise level.
  • Page 12: Function Description

    Signals with wide frequency spectra, low amplitude and long duration, which can be generated by thermal attacks. Alarm Criteria In Detector SC105, the signals detected will be analysed by several parallel software detection modes with specific algorithms for detection of known attack methods and tools, which can be described as below: ...
  • Page 13: Switch Block

    RFI from various transceivers, cellphones and so on. Detector SC105 has a vide supply voltage range from 8 to 16 VDC due to the low internal system voltage of 5 Volt.
  • Page 14: Basic Accessories

    Basic Accessories 4 Basic Accessories Mounting Plate SC110 Movable Mounting Kit SC111 Test Transmitter SC113 Keyhole Protection Kit SC112 Spacer for Keyhole Protection Kit SC118 External Test Transmitter SC115 Armored Cable Kit (8 wires) SC114 - 6 -...
  • Page 15: Planning Protections

    Honeywell 5 Planning Protections Before mounting the detector, it is recommended to plan the mounting locations to achieve an extremely high security level. In general, the detectors should be mounted at the center of the protective surface (see Table 2-1 on page 2.) or on the positions where most of the attacks are aimed at.
  • Page 16: Figure 5-2 Planning Vending Machine/Ticket Machine Protection

    Planning Protections Figure 5-2 Planning Vending Machine/Ticket Machine Protection Close to expected Close to coin/bill compartment attack spot - 8 -...
  • Page 17: Installation

    Honeywell 6 Installation Mounting the Detector Mini-Seismic Vibration Detector SC105 can be mounted on solid surfaces, of which the most common surfaces are Steel, Stainless Steel and Hardened Steel.  Please read first before mounting the detector. TO THE INSTALLER ...
  • Page 18: Mounting On Stainless Steel Or Hardened Steel

    E – Mounting Plate SC110 mounting hole F, G – Welding Slots Refer to the steps below to mount the Detector SC105 on stainless steel or hardened steel. 3. Fix the Mounting Plate SC110 into the 1. Remove paint from the mounting area outline marked and ensure it cannot move, (especially welding area).
  • Page 19: Mounting The Accessories

    The Movable Mounting Kit SC111 The Movable Mounting Kit SC111 consists of one mounting plate on which Detector SC105 is mounted, one Day position plate on which Detector SC105 is positioned during non armed time, and one Night position plate mounted on the protected surface, on which Detector SC105 is positioned during armed time.
  • Page 20: The Armored Cable Kit Sc114

    The SC115 External Test Transmitter is a range test transmitter developed to generate a simulated attack signal in protected object with multiple SC105 seismic detectors installed in concrete vaults and all other solid structure value storage units, checking whether the mounting and the function of the seismic detector is good.
  • Page 21: Settings

    Honeywell 7 Settings All the settings should be configured on the detector base before the detector is installed permanently. The related function modules are shown as below. Figure 7-1 Function modules on Detector Base DIP Switches Noise LED Tamper Switch...
  • Page 22: Eol Jumper Settings

    Settings EOL Jumper Settings Jumper Position EOL Value 2.2K TAMPER 4.7K (RT) 5.6K 2.2K ALARM 4.7K (RA) 5.6K * Factory default settings are shown in grey.  Refer to Control Panel manual for proper EOL selection.  For each block, only one EOL value can be set. Note ...
  • Page 23: Connecting The Detector

    Honeywell 8 Connecting the Detector The terminal block of the Detector SC105 should be wired correctly before the detector cover has been fixed. It is recommended to follow the steps below to wire the pins on the terminal block: Bring and feed the cable through the grommet and cable inlet, see Figure 7-1 Function for reference.
  • Page 24: Test

    Test 9 Test Detector SC105 features two important tests in order to provide the highest level of security:  Control and Function Test - Checking the proper mounting and wiring of the detector before mounting it permanently.  Remote Test - Checking the proper function, mounting and wiring of the detector at any time.
  • Page 25 Detector SC105 and the External Test Trans mitter SC115.
  • Page 26: Technical Specifications

    Technical Specifications 10 Technical Specifications Check the detector mounting and functions regularly (once a year at least). Note Connect Terminal 9 to low level (<0.6VDC), the sensitivity of detector will be reduced to about 1/8 of original level. Power Requirements Supply Voltage 8 ~ 16 VDC, nominal 12 VDC Current Consumption (quiescent)
  • Page 28 © 2010 Honeywell International Inc. All rights reserved. No part of this publication may be reproduced by any means without written permission from Honeywell. The information in this publication is believed to be accurate in all respects. However, Honeywell cannot assume responsibility for any consequences resulting from the use thereof.