GE F35 Instruction Manual page 429

Multiple feeder protection system, ur series
Hide thumbs Also See for F35:
Table of Contents
APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 20 of 57)
ADDR
REGISTER NAME
4585
Source 1 Phase VT
4586
Source 1 Auxiliary VT
4587
...Repeated for Source 2
458E
...Repeated for Source 3
4595
...Repeated for Source 4
459C
...Repeated for Source 5
45A3
...Repeated for Source 6
Power System (Read/Write Setting)
4600
Nominal Frequency
4601
Phase Rotation
4602
Frequency And Phase Reference
4603
Frequency Tracking Function
Incipient Cable Fault Detector (Read/Write Settings) (6 modules)
46B2
Incipient Cable Fault Detector 1 Function
46B3
Incipient Cable Fault Detector 1 Block
46B4
Incipient Cable Fault Detector 1 Source
46B5
Incipient Cable Fault Detector 1 Pickup
46B6
Incipient Cable Fault Detector 1 Mode
46B7
Incipient Cable Fault Detector 1 Trip Counts
46B8
Incipient Cable Fault Detector 1 Time Window
46BA
Incipient Cable Fault Detector 1 Reset Delay
46BB
Incipient Cable Fault Detector 1 Target
46BC
Incipient Cable Fault Detector 1 Events
46BD
...Repeated for Incipient Cable Fault Detector 2
46C8
...Repeated for Incipient Cable Fault Detector 3
46D3
...Repeated for Incipient Cable Fault Detector 4
46DE
...Repeated for Incipient Cable Fault Detector 5
46E9
...Repeated for Incipient Cable Fault Detector 6
Breaker Control (Read/Write Settings)
4700
Breaker 1 Function
4701
Breaker 1 Name
4704
Breaker 1 Mode
4705
Breaker 1 Open
4706
Breaker 1 Close
4707
Breaker 1 Phase A / Three-pole Closed
4708
Breaker 1 Phase B Closed
4709
Breaker 1 Phase C Closed
470A
Breaker 1 External Alarm
470B
Breaker 1 Alarm Delay
470D
Breaker 1 Pushbutton Control
470E
Breaker 1 Manual Close Recall Time
4710
Breaker 1 Out of Service
4711
Breaker 1 Block Open
4712
Breaker 1 Block Close
4713
Breaker 1 Phase A / Three-pole Opened
4714
Breaker 1 Phase B Opened
4715
Breaker 1 Phase C Opened
4716
Breaker 1 Operate Time
4717
Breaker 1 Events
4718
Reserved
4719
...Repeated for Breaker 2
4732
...Repeated for Breaker 3
474B
...Repeated for Breaker 4
4764
...Repeated for Breaker 5
GE Multilin
RANGE
0 to 63
0 to 63
25 to 60
0 to 1
0 to 5
0 to 1
0 to 1
0 to 65535
0 to 5
0.1 to 10
0 to 1
1 to 10
0 to 1000
0 to 65.535
0 to 2
0 to 1
0 to 1
---
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1000000
0 to 1
0 to 1000000
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 1
0 to 65535
F35 Multiple Feeder Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F400
---
1
F400
Hz
1
F001
---
1
F106
---
1
F167
---
1
F102
---
1
F102
---
1
F300
---
1
F167
pu
0.01
F001
---
1
F254
0 (Number of Counts)
---
1
F001
s
0.01
F003
s
0.001
F001
---
1
F109
---
1
F102
---
1
F102
---
---
F206
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F003
---
1
F102
s
0.001
F003
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
---
1
F102
s
1
F001
DEFAULT
0
0
B
60
0 (ABC)
0 (SRC 1)
1 (Enabled)
0 (Disabled)
0
0 (SRC 1)
50
2
1000
100
0 (Self-reset)
0 (Disabled)
0 (Disabled)
"Bkr 1"
0 (3-Pole)
0
0
0
0
0
0
0
0 (Disabled)
0
0
0
0
0
0
0
70
0 (Disabled)
0
B-27