Page 1
Switch Configuration Guide for Dell EMC SC Series SANs Abstract This document illustrates how to configure Dell EMC™ Networking S4148-ON and S4128-ON switches for use with Dell EMC SC Series storage using Dell EMC best practices. October 2017 Dell EMC Configuration and Deployment Guide...
Page 2
Initial release The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose.
3.11 Apply policies and VLAN ID to all switch edge ports ..................15 3.12 iSCSI enable ..............................15 3.13 Save configuration ............................15 3 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
Page 4
Reload ................................18 Verify DCB status ............................. 18 4.10 Configure additional switch ..........................18 Technical support and resources ..........................19 Related resources............................. 19 4 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
Using previous firmware versions may have unpredictable results. Note: The latest firmware updates and documentation can be found at Dell.com/support. 5 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
The cabling diagram shown in Figure 1 represents the Dell EMC recommended method for deploying servers and SC Series arrays. Cabling diagram 6 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
Proceed to reboot the system? [confirm yes/no]yes Note: The switch will reboot. After the startup configuration is deleted, the factory default password is admin. 7 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
Configure out of band (OOB) management port OS10(config)# interface mgmt 1/1/1 OS10(conf-if-ma-1/1/1)# no ip address dhcp OS10(conf-if-ma-1/1/1)# ip address / OS10(conf-if-ma-1/1/1)# exit OS10(config)# 8 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
Save configuration OS10# copy running-configuration startup-configuration OS10# reload System configuration has been modified. Save? [yes/no]: yes Proceed to reboot the system? [confirm yes/no]:yes 10 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
Note: The preceding procedure places all switch ports in the default VLAN. If preferring to place ports in a non-default VLAN, refer to the switch documentation. 11 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
The following commands configure a single VLAN ID. If desired, multiple VLAN IDs can be created on the switch and assigned to ports. OS10(config)# interface vlan OS10(conf-if-vl-)# mtu 9216 OS10(conf-if-vl-)# no shutdown OS10(conf-if-vl-)# exit 12 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
OS10(config)# policy-map type application OS10(config-pmap-application)# class OS10 (config-pmap-c-app)# set qos-group 4 OS10 (config-pmap-c-app)# set cos 4 OS10 (config-pmap-c-app)# exit OS10(config-pmap-application)# exit OS10(config)# 13 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
QoS policy OS10(config)# system qos OS10(config-sys-qos)# service-policy input type qos OS10(config-sys-qos)# service-policy type application OS10(config-sys-qos)# ets mode on OS10(config-sys-qos)# exit OS10(config)# 14 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
OS10# show lldp dcbx interface ethernet 1/1/ ets detail 3.15 Configure additional switches Repeat the commands from section 3 to configure DCB on additional switches. 15 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
OS10# show lldp dcbx interface ethernet 1/1/ 4.10 Configure additional switch Repeat the commands from section 4 to disable DCB on additional switches. 18 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...
For SC Series best practices white papers, reference architectures, and sizing guidelines for enterprise applications and SANs, refer to SC Series Technical Documents. 19 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704...