Extech Instruments EXSTik CL200A User Manual

Extech Instruments EXSTik CL200A User Manual

Waterproof total residual chlorine tester

Quick Links

USER MANUAL
®
ExStik
CL200
A
Waterproof Total Residual Chlorine Tester
Patent Pending
Additional User Manual Translations available at
www.extech.com
Table of Contents
loading

Summary of Contents for Extech Instruments EXSTik CL200A

  • Page 1 USER MANUAL ® ExStik CL200 Waterproof Total Residual Chlorine Tester Patent Pending Additional User Manual Translations available at www.extech.com...
  • Page 2 Introduction ® Congratulations on your purchase of the ExStik CL200 chlorine tester. The CL200 is a revolutionary first of its kind measurement device that offers direct reading of Total Chlorine from ® 0.01 to 10.00 ppm. The electrode method employed by the ExStik is approved by the U.S.
  • Page 3: Meter Description

    Meter Description CL200 Front Panel Description ® The ExStik’s keys have functions which change depending on the electrode ® attached (pH, ORP or Chlorine). Key descriptions here apply for the ExStik with a chlorine electrode attached. 1. Battery compartment 2. LCD Display 3.
  • Page 4: Getting Started

    Getting Started Equipment Required A chlorine test requires a 20ml sample cup, a reagent tablet (see the earlier section ‘Reagent Tablet Health Hazards’ for important safety information), and the CL200 with a chlorine electrode attached. The optional EX006 Weighted base is a recommended accessory. Battery Activation An insulating tab is located in the battery compartment and prevents battery drain during storage.
  • Page 5 Storing Readings 1. Press the MODE button to store a reading. The storage location number will be displayed followed by the stored reading and the “HOLD” indicator. 2. Only one reading can be stored during the 120 second measurement cycle. 3.
  • Page 6 Considerations and Techniques to Preserve the Electrode If the meter has not been used for several weeks or is new, at least two tests should be made to condition the electrode. Do not touch the reagent tablets. Touching can cause contamination. See the earlier section ‘Reagent Tablet Health Hazards’...
  • Page 7: Maintenance

    Maintenance Battery Replacement Twist off the battery compartment cap Replace the four (4) CR2032 batteries observing polarity. Replace the battery compartment cap Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold.
  • Page 8: Specifications

    Specifications Display Multifunction LCD with Bargraph Operating conditions 32 to 122 F (0 to 50 C) and < 80% RH Chlorine range 0.01 to 10.00 ppm (Total Chlorine) Chlorine accuracy 0.05 to 5.00ppm; ± (10%reading + 0.01ppm) 5.00 to 10.00ppm; ± (15%reading + 0.05ppm) Temperature measurement range -5 to 90 C (23 to 194...