Electrical Installation; Connections - Allen-Bradley GuardShield Safe 2 PAC User Manual

Safety light curtains
Table of Contents
Figure 11: Different mounting brackets for Safe 2
Safe 2 Shock Mounting Kit
Rockwell Automation offers a shock and vibration isolation kit for
vertically mounting the Safe 2. This kit is most effective in protecting the
internal optical and electronic components of the Safe 2 light curtain.
The best performance of the shock and vibration isolation kit is attained
when the kit is used in conjunction with the Safe 2 vertical mounting
brackets (445L-AF6144).
R
11
(0.43)
M6x40
29.5
(1.16)
M4x16
445L-AF6140
Standard mounting brackets—supplied with each
light curtain
For side mounting
Adjustable by ± 4°
(Two brackets per kit.)
M6x60
17
(0.67)
M4x12
40.8
135
(1.60)
(5.31)
445L-AF6144
Vertical mounting brackets (optional)
For mounting in the vertical axis of the light curtain
Adjustable by ± 4°
(Two brackets per kit.)
37
(1.46)
70
(2.76)
36.4
(1.43)
445L-AF6141
180° Mounting, rotation ±90°, for applications
where the mounting angle is not set using the
mounting frame.
(Two brackets per kit.)
Original instructions
GuardShield™ Safe 2 Safety Light Curtain User Manual
M 6x25 Socket head cap screw, fully threaded
20
20
(0.79) dia.
(0.79)
18
(0.71)
Figure 12: Shock Isolator

Electrical Installation

Connections

Power Supply
The external voltage supply (+24V DC) must meet the requirements of
IEC 61496-1. In addition, the following requirements have to be
fulfilled:
• A short-term power failure of 20 ms must be bridged by the power
supply.
• The power supply has double insulation between the primary and
the secondary side.
• The power supply is protected against overload.
• The power supply corresponds to the guidelines of the EWG
(industrial environment).
• The power supply corresponds to the Low Voltage Directives.
• The grounded conductor of the power supply device must be
connected to a grounded conductor PE.
• The maximum deviation of the voltage levels is 24V DC +/- 20%.
Double insulation
Basic insulation
Output (pink
and grey)
Guard
0V (blue)
Shield
+24V (brown)
K1
K1
Power
Supply
Unit 2
Unit 1
Reinforced
insulation or
double
Hazardous
insulation
voltage level
M 6x6.1/14 Lock washer
Vibration damper
M6
M 6x6.1/14 Lock washer
This part of the insulation provides
supplementary insulation against
hazardous voltage levels.
Basic insulation
K2
K2
Motor, etc.
Hazardous voltage level
Basic insulation
Hazardous
voltage level
11