Table 9-2 Action List For Stop Error Code 0X80 - Hitachi HF-W2000 Instruction Manual

Industrial computer
Table of Contents
9. TROUBLESHOOTING
Contents logged in event log
(Event ID:800, Sourse:HFWRAS_SYS)
Reset signal was input.
Detailed code = 0x9201
PCI Bus Parity Error was occurred
Detailed code = 0x9202.
Uncorrectable Error at DIMM B1.
Detailed code = 0x9217
Uncorrectable Error at DIMM A1.
Detailed code = 0x9218

Table 9-2 Action list for STOP Error Code 0x80

Forced recovery from
CPU lock
Hardware NMI
Uncorrectable memory
error
Cause
Before a message appears, check whether the
reset switch is pressed.
Remove the extension board and replace it
with another board and recheck operation. For
the replacement work, see "6.4 Installing and
Removing Components".
Check whether the main memory is mounted
correctly. If this error still occurs with the
main memory mounted correctly, it may be
due to a main memory failure. Contact the
system administrator or maintenance
personnel.
9-20