GE LOGIQ V5 Service Manual
Hide thumbs Also See for LOGIQ V5:
Table of Contents

Quick Links

GE
LOGIQ V5/LOGIQ V3
Basic Service Manual
Part Number: 5496012-100
Revision: 3
Table of Contents
loading

Summary of Contents for GE LOGIQ V5

  • Page 1 LOGIQ V5/LOGIQ V3 Basic Service Manual Part Number: 5496012-100 Revision: 3...
  • Page 3 • VERSUCHEN SIE NICHT, DAS GERä T ZU REPARIEREN, BEVOR DIESES WARNUNG KUNDENDIENST-HANDBUCH NICHT ZU RATE GEZOGEN UND VERSTANDEN (DE) WURDE. • WIRD DIESE WARNUNG NICHT BEACHTET, SO KANN ES ZU VERLETZUNGEN DES KUNDENDIENSTTECHNIKERS, DES BEDIENERS ODER DES PATIENTEN DURCH ELEKTRISCHE SCHLä GE, MECHANISCHE ODER SONSTIGE GEFAHREN KOMMEN.
  • Page 4 LOGIQ V5/LOGIQ V3 5496012-100 , R IRECTION EVISION ASIC ERVICE ANUAL ESTE MANUAL DE SERVICIO Só LO EXISTE EN INGLé S. • SI ALGú N PROVEEDOR DE SERVICIOS AJENO A GEHC SOLICITA UN IDIOMA QUE NO SEA EL INGLé S, ES RESPONSABILIDAD DEL CLIENTE OFRECER UN SERVICIO DE TRADUCCIó...
  • Page 5 ΣΤΟΝ ΑΣΘΕΝΗ ΑΠΟ ΗΛΕΚΤΡΟΠΛΗΞΙΑ, ΜΗΧΑΝΙΚΟΥΣ Ή ΑΛΛΟΥΣ ΚΙΝ∆ΥΝΟΥΣ. EZEN KARBANTARTÁSI KÉZIKÖNYV KIZÁRÓLAG ANGOL NYELVEN ÉRHETŐ EL. • HA A VEVŐ SZOLGÁLTATÓJA ANGOLTÓL ELTÉRŐ NYELVRE TART IGÉNYT, AKKOR A VEVŐ FELELŐSSÉGE A FORDÍTÁS ELKÉSZÍTTETÉSE. • NE PRÓBÁLJA ELKEZDENI HASZNÁLNI A BERENDEZÉST, AMÍG A FIGYELMEZTETÉS KARBANTARTÁSI KÉZIKÖNYVBEN LEÍRTAKAT NEM ÉRTELMEZTÉK.
  • Page 6 LOGIQ V5/LOGIQ V3 5496012-100 , R IRECTION EVISION ASIC ERVICE ANUAL ÞESSI ÞJÓNUSTUHANDBÓK ER EINGÖNGU FÁANLEG Á ENSKU. • EF ÞJÓNUSTUAÐILI VIÐSKIPTAMANNS ÞARFNAST ANNARS TUNGUMÁLS EN ENSKU, ER ÞAÐ Á ÁBYRGÐ VIÐSKIPTAMANNS AÐ ÚTVEGA ÞÝÐINGU. • REYNIÐ EKKI AÐ ÞJÓNUSTA TÆKIÐ NEMA EFTIR AÐ HAFA SKOÐAÐ OG VIÐVÖRUN...
  • Page 7 LOGIQ V5/LOGIQ V3 5496012-100 , R IRECTION EVISION ASIC ERVICE ANUAL šĪ APKALPES ROKASGRĀMATA IR PIEEJAMA TIKAI ANGĻU VALODĀ. • JA KLIENTA APKALPES SNIEDZĒJAM NEPIECIEŠAMA INFORMĀCIJA CITĀ VALODĀ, NEVIS ANGĻU, KLIENTA PIENĀKUMS IR NODROŠINĀT TULKOŠANU. • NEVEICIET APRĪKOJUMA APKALPI BEZ APKALPES ROKASGRĀMATAS BRĪDINĀJUMS...
  • Page 8 LOGIQ V5/LOGIQ V3 5496012-100 , R IRECTION EVISION ASIC ERVICE ANUAL ACEST MANUAL DE SERVICE ESTE DISPONIBIL NUMAI ÎN LIMBA ENGLEZĂ. • DACĂ UN FURNIZOR DE SERVICII PENTRU CLIENŢI NECESITĂ O ALTĂ LIMBĂ DECÂT CEA ENGLEZĂ, ESTE DE DATORIA CLIENTULUI SĂ FURNIZEZE O TRADUCERE.
  • Page 9 LOGIQ V5/LOGIQ V3 5496012-100 , R IRECTION EVISION ASIC ERVICE ANUAL TA SERVISNI PRIROČNIK JE NA VOLJO SAMO V ANGLEŠČINI. • ČE PONUDNIK SERVISNIH STORITEV ZA STRANKO POTREBUJE NAVODILA V DRUGEM JEZIKU, JE ZA PREVOD ODGOVORNA STRANKA SAMA. • NE POSKUŠAJTE SERVISIRATI OPREME, NE DA BI PREJ PREBRALI IN OPOZORILO RAZUMELI SERVISNI PRIROČNIK.
  • Page 10 LOGIQ V5/LOGIQ V3 5496012-100 , R IRECTION EVISION ASIC ERVICE ANUAL BU SERVİS KILAVUZU YALNIZCA İNGİLİZCE OLARAK SAĞLANMIŞTIR. • EĞER MÜŞTERİ TEKNİSYENİ KILAVUZUN İNGİLİZCE DIŞINDAKİ BİR DİLDE OLMASINI İSTERSE, KILAVUZU TERCÜME ETTİRMEK MÜŞTERİNİN SORUMLULUĞUNDADIR. DİKKAT • SERVİS KILAVUZUNU OKUYUP ANLAMADAN EKİPMANLARA MÜDAHALE (TR) ETMEYİNİZ.
  • Page 11 LOGIQ V5/LOGIQ V3 5496012-100 , R IRECTION EVISION ASIC ERVICE ANUAL (ZH-CN) (KO)
  • Page 12: Part Number

    GE personnel. In performing all electrical work on these products, GE will use its own specially trained field engineers. All of GE’s electrical work on these products will comply with the requirements of the applicable electrical codes.
  • Page 13 If you are a GE employee or a customer who has entered into such a license agreement with GE to use this proprietary software, you are authorized to use this Material according to the conditions stated in your license agreement.
  • Page 14 LOGIQ V5/LOGIQ V3 5496012-100 , R IRECTION EVISION ASIC ERVICE ANUAL Revision History Revision Date Reason for change 2014/03/20 Initial Release 2014/07/10 Update the CRU list 2014/12/23 Update the CRU list List of Effected Pages (LOEP) Pages Revision Pages Revision...
  • Page 15: Table Of Contents

    Purpose of Operator Manual(s) ........1 - 2 LOGIQ V5/LOGIQ V3 Models Covered by this Manual ....1 - 2 Peripheral List .
  • Page 16 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL CHAPTER 2 Site Preparations Overview ............2 - 1 Purpose of chapter 2 .
  • Page 17 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL CHAPTER 3 System Setup Overview............3 - 1 Purpose of Chapter 3 .
  • Page 18 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL CHAPTER 4 Functional Checks Overview ............4 - 1 Purpose for Chapter 4 .
  • Page 19 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL CHAPTER 5 Components and Functions (Theory) Overview............5 - 1 Purpose of Chapter 5 .
  • Page 20 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL CHAPTER 6 Service Adjustments Overview ............6 - 1 Purpose of this chapter 6 .
  • Page 21 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL CHAPTER 7 Diagnostics/Troubleshooting Overview............7 - 1 Purpose of Chapter 7 .
  • Page 22 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL CHAPTER 8 Replacement Procedures Overview ............8 - 1 Purpose of Chapter 8 .
  • Page 23 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL CHAPTER 9 Renewal Parts Overview............9 - 1 Purpose of Chapter 9 .
  • Page 24 Standard GE Tool Kit ........
  • Page 25: Overview

    8.) Chapter 8 - Replacement Procedures: Provides disassembly procedures and reassembly procedures for all changeable Customer Replaceable Units (CRU). 9.) Chapter 9 - Renewal Parts: Contains a complete list of field replaceable parts for the LOGIQ V5/ LOGIQ V3. 10.)Chapter 10 - Care & Maintenance: Provides periodic maintenance procedures for the LOGIQ V5/ LOGIQ V3.
  • Page 26: Typical Users Of The Basic Service Manual

    Contractors (Some parts of Chapter 2 - Pre-Installation) 1-1-4 Purpose of Operator Manual(s) The Operator Manual(s) should be fully read and understood before operating the LOGIQ V5/LOGIQ V3 and also kept near the unit for quick reference. NOTE: Probe information displayed on screen does not necessarily reflect the probes available on your ultrasound system.
  • Page 28 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 1-3 LOGIQ V Model Designations Item Part Name Part Number 1013 1TB mobile USB HDD 5434317-3 Biopsy Kit 1014 E8C-RS biopsy kit E8385NA 1015 E8C-RS reusable biopsy kit 2398164...
  • Page 29: Important Conventions

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 1-2 Important Conventions 1-2-1 Conventions Used in Book Icons Pictures, or icons, are used wherever they reinforce the printed message. The icons, labels and conventions used on the product and in the service information are described in this chapter.
  • Page 30: Standard Hazard Icons

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 1-2-2 Standard Hazard Icons Important information will always be preceded by the exclamation point contained within a triangle, as seen throughout this chapter. In addition to text, several different graphical icons (symbols) may be used to make you aware of specific types of hazards that could cause harm.
  • Page 31: Product Icons

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 1-2-3 Product Icons The following table describes the purpose and location of safety labels and other important information provided on the equipment. Table 1-6 Product Icons LABEL/SYMBOL PURPOSE/MEANING LOCATION Label/Icon...
  • Page 32 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 1-6 Product Icons LABEL/SYMBOL PURPOSE/MEANING LOCATION Indicates the presence of hazardous substance(s) Probe and Rear Panel, China above the maximum concentration value. Maximum Rating Plate concentration values for electronic information products, as set by the People’s Republic of China...
  • Page 33 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 1-6 Product Icons LABEL/SYMBOL PURPOSE/MEANING LOCATION Do not put your whole body weight on the Footrest foot-rest holder. INMETRO Certification: TUV Rheinland Rating plate Brazil Note: Only after Brazilian...
  • Page 34: Safety Considerations

    1-3-2 Human Safety Servicing should be performed by authorized personnel only. Only personnel who have participated in a LOGIQ V5/LOGIQ V3 Training are authorized to service the equipment. 1-3-3 Mechanical Safety...
  • Page 35: Electrical Safety

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 1-3-3 Mechanical Safety (cont’d) NOTE: Special care should be taken when transporting the unit in a vehicle: • Secure the unit in an upright position. • Lock the wheels (brake)
  • Page 36: Dangerous Procedure Warnings

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 1-3-6 Dangerous Procedure Warnings Warnings, such as the examples below, precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed. DANGEROUS VOLTAGES, CAPABLE OF CAUSING DEATH, ARE PRESENT DANGER IN THIS EQUIPMENT.
  • Page 37: Returning/Shipping Probes And Repair Parts

    Equipment being returned must be clean and free of blood and other infectious substances. GE policy states that body fluids must be properly removed from any part or equipment prior to shipment. GE employees, as well as customers, are responsible for ensuring that parts/equipment have been properly decontaminated prior to shipment.
  • Page 38: Lockout/Tagout (Loto) Requirements

    5.) Control all stored and residual energy. 6.) Verify isolation. All potentially hazardous stored or residual energy is relieved. Energy Control and Power Lockout for LOGIQ V5/LOGIQ V3 NOTICE WHEN SERVICING PARTS OF THE SYSTEM WHERE THERE IS EXPOSURE TO VOLTAGE GREATER THAN 30 VOLTS: 1.
  • Page 39: Emc, Emi, And Esd

    1-5-2 CE Compliance The LOGIQ V5/LOGIQ V3 unit conforms to all applicable conducted and radiated emission limits and to immunity from electrostatic discharge, radiated and conducted RF fields, magnetic fields and power line transient requirements.
  • Page 40: Customer Assistance

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 1-6 Customer Assistance 1-6-1 Contact Information If this equipment does not work as indicated in this service manual or in the User Manual, or if you require additional assistance, please contact the local distributor or appropriate support resource, as listed below.
  • Page 41: System Manufacturer

    ANUAL 1-6-2 System Manufacturer Table 1-8 System Manufacturer Manufacturer FAX Number GE Medical Systems (China) Co., Ltd. TEL: +86 510-85225888 No.19, Changjiang Road, Wuxi National Hi-Tech Development Zone, FAX: +86 510-85226688 Jiangsu, P.R. China 214028 1-6-3 Factory Site Table 1-9...
  • Page 42 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL This page was intentionally left blank. 1 - 18 Section 1-6 - Customer Assistance...
  • Page 43: Site Preparations

    2-1-1 Purpose of chapter 2 This chapter provides the information required to plan and prepare for the installation of LOGIQ V5/ LOGIQ V3. Included are descriptions of the facility and electrical needs to be met by the purchaser of the unit.
  • Page 44: General Console Requirements

    Electrical Requirements NOTE: GE Healthcare requires a dedicated power and ground for the proper operation of its Ultrasound equipment. This dedicated power shall originate at the last distribution panel before the system. Sites with a mains power system with defined Neutral and Live: The dedicated line shall consist of one phase, a neutral (not shared with any other circuit), and a full size ground wire from the distribution panel to the Ultrasound outlet.
  • Page 45 2-2-2-5 Unit Power Plug If the unit arrives without the power plug, or with the wrong plug, you must contact your GE dealer or the installation engineer must supply what is locally required. 2-2-2-6 Power Stability Requirements Voltage drop-out Max 10 ms.
  • Page 46: Emi Limitations

    Ultrasound machines are susceptible to Electromagnetic Interference (EMI) from radio frequencies, magnetic fields, and transient in the air wiring. They also generate EMI. The LOGIQ V5/LOGIQ V3 complies with limits as stated on the EMC label. However there is no guarantee that interface will not occur in a particular installation.
  • Page 47: Scan Probe Environmental Requirements

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 2-2-4 Scan Probe Environmental Requirements Operation: 10° to 40° C Storage: -5° to 50° C NOTE: Temperature in degrees C. Conversion to Degrees F = (Degrees C * (9/5) + 32).
  • Page 48: Facility Needs

    All electrical work on these product must comply with the requirements of applicable electrical codes. The purchaser of GE equipment must only utilize qualified personnel to perform electrical servicing on the equipment.
  • Page 49: Required Features

    2-3-2 Required Features NOTE: GE Medical Systems requires a dedicated power and ground for the proper operation of its Ultrasound equipment. This dedicated power shall originate at the last distribution panel before the system. Sites with a mains power system with defined Neutral and Live: The dedicated line shall consist of one phase, a neutral (not shared with any other circuit), and a full size ground wire from the distribution panel to the Ultrasound outlet.
  • Page 50: Minimal Floor Plan Suggestion

    3. Counter Top, Sink with hot and cold 7. Footswitch from wall or objects water and Supplies Storage 8. Stool 14. GE Cabinet for Software and Manuals 4. Linen Supply 9. Ultrasound system 5. Probes/Supplies 10. External Peripherals 11. Dedicated Power Outlet - Circuit...
  • Page 51: Recommended Floor Plan Suggestion

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 2-3-4 Recommended floor plan suggestion Recommended standard floor plan and a minimal floor plan for ultrasound equipment: Figure 2-1 RECOMMENDED ULTRASOUND ROOM LAYOUT Scale: Each square equals one square foot (app. 31 x 31 cm) 1.
  • Page 52: Suggested Floor Plan, Ultrasound System, And Echopac Pc In Same Room

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 2-3-5 Suggested floor plan, Ultrasound system, and EchoPAC PC in same room 1. EchoPAC PC workstation parts 4. 3x mains power outlets 7. Ethernet network wall outlet 2. UPS 5. Hot and Cold water 3.
  • Page 53: Networking Pre-Installation Requirements

    Information must include: • A host name, local port number, AE Title, IP address and Net Mask for the LOGIQ V5/LOGIQ V3. • The IP addresses for the default gateway and other routers at the site for ROUTING INFORMATION.
  • Page 54 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 2-3-6-4 DICOM Option Pre-installation Requirements (cont’d) LOGIQ V5/ IP Address Local Port Host Name AE Title Net Mask ROUTING INFORMATION GATEWAY IP Addresses Destination IP Addresses Default ROUTER1 ROUTER2 ROUTER3...
  • Page 55: System Setup

    How to prepare the facility and unit of the actual installation, and how to check and test the unit and external peripherals for electrical safety are included in this procedure. Also included LOGIQ V5/LOGIQ V3 in this section are guidelines for transporting the unit to a new site.
  • Page 56: Setup Reminders

    DICOM Option Dependant on the amount of configuration The LOGIQ V5/LOGIQ V3 has been designed to be installed and checked out by an experienced service technician in approximately 1 hour. LOGIQ V5/LOGIQ V3 consoles with optional equipment may take slightly longer.
  • Page 57: Installation Warnings

    3-2-2 Installation Warnings 1.) Since the LOGIQ V5/LOGIQ V3 weighs approximately 50 kg without options, preferably two people should unpack it. Two people are also preferable for installing any additional bulky items. 2.) There are no operator serviceable components. To prevent shock, do not remove any covers or panels.
  • Page 58: Safety Reminders

    System performance and cooling require this. OPERATOR MANUAL(S) CAUTION The User Manual(s) should be fully read and understood before operating the LOGIQ V5/ LOGIQ V3 and kept near the unit for quick reference. Figure 3-1 Environmental Labels 3 - 4...
  • Page 59: Receiving And Unpacking The Equipment

    Do not lift the unit by the Keyboard. Equipment damage may result. CAUTION The crate with the LOGIQ V5/LOGIQ V3 weighs approximately 50kg. Be prepared for a sudden CAUTION shift of weight as the unit is removed from its base (pallet)
  • Page 60 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 3-4: Unpacking the equipment Step Description Corresponding Graphic Open the four plastic locks. Note: Rotate the inside plastic lock counterclockwise to remove it and then remove the outside lock.
  • Page 61 Step Description Corresponding Graphic Remove the clear plastic (wrapped around the LOGIQ V5/LOGIQ V3) from the unit. Note: To avoid damaging the unit, please use a pair of scissors instead of the knife. Remove the accessory box. Chapter 3 - System Setup...
  • Page 62 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 3-4: Unpacking the equipment Step Description Corresponding Graphic Remove the foams beside the LCD monitor and the control panel. Cut the packing straps around the four wheels and remove the foams beside the wheels.
  • Page 63: Moving Into Position

    To avoid injury by tipping over. Set the monitor to the lowest position before moving. In general, a single adult can move the LOGIQ V5/LOGIQ V3 along an even surface with no steep grades. At least two people should move the machine when large humps, grooves, or grades will be encountered.
  • Page 64: Preparing For Installation

    System Voltage Settings Verify that Docking Cart is set to the correct voltage. The Voltage settings for the LOGIQ V5/LOGIQ V3 is found on a label to the right of the Power switch and External I/O, on the rear of the system.
  • Page 65: Completing The Installation

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 3-5 Completing the Installation 3-5-1 Power On / Boot Up NOTE: After turning off a system, wait at least ten seconds before turning it on again. The system may not be able to boot if power is recycled too quickly.
  • Page 66: Power Off/ Shutdown

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 3-5-2 Power Off/ Shutdown NOTE: After turning off a system, wait at least ten seconds before turning it on again. The system may not be able to boot if power is recycled too quickly.
  • Page 67: System Configuration

    Section 3-6 System Configuration 3-6-1 System Specifications 3-6-1-1 Physical Dimensions The physical dimensions of the LOGIQ V5/LOGIQ V3 unit are summarized in Table 3-5 on page 3-13. The Size of LOGIQ V5/LOGIQ V3. Table 3-5 Physical Dimensions of LOGIQ V5/LOGIQ V3...
  • Page 68: Connecting Cables

    Figure NOTE USB Cable For USB Printer 3-6-5 Peripherals/Accessories Connector Panel LOGIQ V5/LOGIQ V3 peripherals and accessories can be properly connected using the side connector panel. 3-6-5-1 Rear Panel Connector Figure 3-5 Rear Connector Panel NOTE: The AC printer can be connected to the isolated Printer USB port on the rear panel only.
  • Page 69 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 3-6-5Peripherals/Accessories Connector Panel (cont’d) Table 3-10 Peripheral/Accessory Connector Panel HDMI port HDMI out Isolated Printer USB port For AC Printer ONLY USB Ports USB Ports Ethernet LAN for InSite Connection (RJ45) Circuit breaker 6.5A...
  • Page 70 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 3-14 Pin Assignment of S-Video Pin No. Output Signal Pin No. Output Signal Table 3-15 Pin Assignment of Composite Video Out Pin No. Output Signal Pin No. Output Signal...
  • Page 71 Sony UP-D711MD Printer can be properly connected using the STD and DC cables. Figure 3-6 Connect B/W printer to the system Sony UP-D711MD is connected to the LOGIQ V5/LOGIQ V3 system via the STD and DC cables under the control panel.
  • Page 72 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 3-6-5-3Connect Peripherals (cont’d) B.) Connect Sony UP-D25MD color printer to the system. Sony UP-D25MD Color Printer can be properly connected using the isolated Printer USB Port. And connect the power cable of Sony UP- D25MD to the wall outlet.
  • Page 73 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 3-6-5-3 Connect Peripherals (cont’d) C.) Connect the B/W printer (Sony UP-897/Sony UP-D898MD) to the system The B/W printer can be properly connected using the isolated Printer USB Port. And connect the power cable of Sony UP-D897/Sony UP-D898MD to the wall outlet.
  • Page 74 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 3-6-5-3Connect Peripherals (cont’d) E.) Connect Foot Switch to the system. Foot Switch can be properly connected using USB Ports. 1-Pedal Footswitch 3-Pedal Footswitch Figure 3-11 Connect Foot Switch to the system...
  • Page 75 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 3-6-5-3Connect Peripherals (cont’d) F.) Connect the USB Memory to the system. The USB Memory can be properly connected using the USB ports. Figure 3-12 USB Memory Connection G.) Connect the USB HDD to the system. The USB Harddisk can be properly connected using USB ports.
  • Page 76 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 3-6-5-4 Digital Printer Setup There are two steps to do when setting up a digital printer: 1. follow the procedure below for each printer, then 2. set up specific properties for each printer if you need.
  • Page 77 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Digital Printer 3-6-5-5 Instructions Follow these steps to set up the paper size of the printer, take Sony UP-D897 as an example. 1.) Press Utility-->System-->Peripherals. Select the UP-D897 from the pull-down menu under Standard Printer Properties.
  • Page 78: Available Probes

    EVISION ASIC ERVICE ANUAL 3-6-6 Available Probes See in specification in the LOGIQ V5/LOGIQ V3 User Reference Manual for Probes and intended use. Table 3-16 List of Probes on LOGIQ V5/LOGIQ V3 Probe Name Material of Headshell Area of Using...
  • Page 79: Connectivity Installation Worksheet

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 3-8 Connectivity Installation Worksheet Site System Information Comments: Floor: Site: Dept: Room: LOGIQ SN: Type: REV: CONTACT INFORMATION Name Title Phone E-Mail Address TCP/IP Settings Name - AE Title:...
  • Page 80: Loading Base Image Software

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 3-9 Loading Base Image Software Refer to Section 8-3 "Loading Base Image Software" on page 8-4. 3 - 26 Section 3-9 - Loading Base Image Software...
  • Page 81: Software Version Check Out

    Section 3-10Software Version check out 3-10-1 Functional Check-out 1.) Power on LOGIQ V5/LOGIQ V3 scanner and wait until system booting to main screen. 2.) Press Utility key on control panel. 3.) Choose the About button on the right. Figure 3-20 About and Software version 4.) Check whether “Software version”...
  • Page 82: Paperwork

    User Manual(s) User Check that the correct User Manual(s) for the system and software revision, is included with the installation. Specific language versions of the User Manual may also be available. Check with your GE Sales Representative for availability. 3 - 28...
  • Page 83: Overview

    Section 4-1 Overview 4-1-1 Purpose for Chapter 4 This chapter provides procedures for quickly checking major functions of the LOGIQ V5/LOGIQ V3 console, diagnostics by using the built-in service software, and power supply. Table 4-1 Contents in Chapter 4 Section...
  • Page 84: General Procedure

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 4-3 General Procedure SYSTEM REQUIRES ALL COVERS CAUTION Operate this unit only when all board covers and frame panels are securely in place. The covers are required for safe operation, good system performance and cooling purposes.
  • Page 85: Power Off/ Shutdown

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-2 Power Off/ Shutdown NOTE: After turning off a system, wait at least ten seconds before turning it on again. The system may not be able to boot if power is recycled too quickly.
  • Page 86 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-2-3 Check System Date and Time A warning message “Please check the system date and time are correct” appears on the screen when the system is powered on. This warning message appears for the possible reasons: •...
  • Page 87: Archiving And Loading Presets

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-3 Archiving and Loading Presets NOTE: Always save presets before any software reload. This ensures the presets loaded after the software reload are as up–to–date as possible. All user presets except changes to Summary, Anatomy, and Biometry pages, can be saved on an CD- R disk (or USB memory device) for reloading on the system.
  • Page 88: Adjusting The Display Monitor

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-3-2 Loading Presets from an CD-R disk (or USB memory device) 1.) Insert the CD-R disk with the archived Presets into the DVD-RW. 2.) Access to the Utility Menu, and select System. The Restore sheet will be shown on the LCD display.
  • Page 89: System Features

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-5 System Features 4-3-5-1 Control Panel Figure 4-5 Control Panel Tour 1. Power On/Off 11. End Exam key 21. M/D Cursor key 2. Rotary Button 12. Archive key 22. Scan Area key 3.
  • Page 90 EVISION ASIC ERVICE ANUAL 4-3-5-2 LOGIQ V5/LOGIQ V3 SoftMenu Key Tour 1.) Rotary key: Rotate to adjust the menu. 2.) Page Up/Down key: To turn the menu page up and down. Figure 4-6 SoftMenu Key Tour 4 - 8 Section 4-3 - General Procedure...
  • Page 91 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-5-3 Monitor Display Figure 4-7 Monitor Display Tour 1. Institution/Hospital Name, Date, Time, Operator 14. Image Preview. Identification. 15. Measurement Summary Window. 2. Patient Name, Patient Identification. 16. Worksheet/Direct Report.
  • Page 92: B Mode Checks

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-6 B Mode Checks 4-3-6-1 Preparations 1.) Connect one of the probes listed in 3-6-6 "Available Probes" on page 3-24, in Chapter 3 Installation to the System probe connector. 2.) Turn ON the scanner (if it isn’t turned on already).
  • Page 93 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-6-2 B Mode Controls Table 4-2 B Mode Controls Description/Benefit Control Possible Bioeffect Depth Depth controls the distance over which the B-Mode images anatomy. To visualize deeper structures, increase the depth. If there is a large part of the display which is unused at the bottom, decrease the depth.
  • Page 94 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 4-2 B Mode Controls Description/Benefit Control Possible Bioeffect Tilt You can steer the sector angle to get more information without moving the probe while in B-Mode, M-Mode, Doppler Mode, and Color Flow Mode.
  • Page 95 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 4-2 B Mode Controls Description/Benefit Control Possible Bioeffect SRI-HD SRI-HD (Speckle Reduction Imaging High Definition) is an adaptive algorithm to reduce the unwanted effects of speckle in the ultrasound image. Image speckle usually appears as a grainy texture in otherwise uniform areas of tissue.
  • Page 96: M Mode Controls

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-7 M Mode Controls 4-3-7-1 Preparations 1.) Connect one of the probes listed in 3-6-6 "Available Probes" on page 3-24, in Chapter 3 Installation to the System probe connector. 2.) Turn ON the scanner (if it isn’t turned on already).
  • Page 97 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-7-2 M Mode Controls Table 4-3 M Mode Controls Control Possible Bioeffect Description/Benefit Sweep Speed Changes the speed at which the timeline is swept. Available in M-Mode, Doppler Mode and M Color Flow Mode.
  • Page 98: Doppler Mode Checks

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-8 Doppler Mode Checks 4-3-8-1 Preparations 1.) Connect one of the probes listed in 3-6-6 "Available Probes" on page 3-24, in Chapter 3 Installation to the System probe connector. 2.) Turn ON the scanner (if it isn’t turned on already).
  • Page 99 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-8-2 Doppler Mode Controls Table 4-4 Doppler Mode Controls Control Possible Bioeffect Description/Benefit Auto Spectral Auto in Doppler Mode optimizes the spectral data. Auto Optimize [ASO] adjusts the Velocity Scale/PRF (on live images only), (Auto) baseline shift, Dynamic Range and invert (if preset).
  • Page 100 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 4-4 Doppler Mode Controls Control Possible Bioeffect Description/Benefit Display Format Changes the horizontal/vertical layout between B-Mode and M-Mode, or timeline only. Modify Auto Calcs Activates the menu to select which calculations are automatically calculated.
  • Page 101: Color Flow Mode Checks

    ASIC ERVICE ANUAL 4-3-9 Color Flow Mode Checks NOTE: Color Flow Mode only support by LOGIQ V5. 4-3-9-1 Preparations 1.) Connect one of the probes listed in 3-6-6 "Available Probes" on page 3-24, in Chapter 3 Installation to the System probe connector.
  • Page 102 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-9-2 Color Flow Mode Controls Table 4-5 Color Flow Mode Controls Control Possible Bioeffect Description/Benefit Flow Selection In the Lower Extremity Vein (LEV) and Abdominal applications, you can quickly select the flow state via a shortcut on the Color Flow Mode menu.
  • Page 103 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 4-5 Color Flow Mode Controls Control Possible Bioeffect Description/Benefit CF/PDI Auto Set the default value at Utility -> Imaging -> CF Mode. Sample Volume CF/PDI Focus Depth CF/PDI Frequency...
  • Page 104: Basic Measurements

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-10 Basic Measurements NOTE: The following instructions assume that you first scan the patient and then press Freeze. 4-3-10-1 Distance and Tissue Depth Measurements 1.) Press Measure once, an active caliper displays.
  • Page 105: Probe/Connectors Usage

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-10-4 Report Pages Measurements/Calculations that are included on the worksheet can also be displayed on Report Pages. Report Pages can be customized to meet the appropriate needs of the user.
  • Page 106: Using Cine

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-12 Using Cine 4-3-12-1 Activating CINE Press Freeze, then roll the Trackball to activate CINE. To start CINE Loop playback, rotate Run/Stop button. To stop CINE Loop playback, rotate Run/Stop button.
  • Page 107: Backup And Restore Database, Preset Configurations And Images

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-13 Backup and Restore Database, Preset Configurations and Images 4-3-13-1 Formatting Media 1.) To format the backup media, enter Utility-> Connectivity->Removable Media. 2.) Select the media type from the drop down menu.
  • Page 108 2.) Enter enter Utility-> System-> Backup/Restore. NOTE: If you are not logged in as GE Service or with administrator privileges, the Operator Login window is displayed. Log on with administrator privileges. 3.) In the Backup list, select Patient Archive, Report Archive, User Defined Configuration and Service.
  • Page 109 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-13-3 Restore System Presets and Configurations The restore procedure overwrites the existing database on the local hard drive. Make sure to insert CAUTION the correct CD (or USB memory device).
  • Page 110 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-13-4 Archiving Images 1.) Insert the archive media. 2.) To format the archive media, enter Utility-> Connectivity-> Removable Media. 3.) Format the CD. Verify the format if desired. 4.) Images will be moved from the hard drive by date. Therefore, the best way is to label media by date.
  • Page 111 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-13-4 Archiving Images (cont’d) 7.) Go to Archive menu and select EZBackup/EZMove, the EZBackup/EZMove wizard starts. Figure 4-22 Archive Screen 8.) Verify the information on the first page of EZBack/EZMove wizard, then select Next.
  • Page 112 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-13-4 Archiving Images (cont’d) 9.) It indicates the size of the data and the storage. Select Next to continue. NOTE: The calculation for the number of backup CD is only an estimate. Allow for one additional CD when performing an EZBack/EZMove.
  • Page 113 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4-3-13-4 Archiving Images (cont’d) 10.)The status menu appears. When the backup/move has been complete, press Next. Figure 4-26 EZBackup Wizard 3 NOTE: If you need to insert the next media, a message appears providing you with the media label.
  • Page 114: Software Configuration Checks

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 4-4 Software Configuration Checks Table 4-6 Software Configuration Checks Step Task to do Expected Result(s) Check Date and Time setting Date and Time are correct Check that Location (Hospital Name) is correct...
  • Page 115 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL This page was intentionally left blank. Chapter 4 - Functional Checks 4 - 33...
  • Page 116 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 4 - 34 Section 4-5 - Peripheral Checks...
  • Page 117: Overview

    ANUAL Chapter 5 Components and Functions (Theory) Section 5-1 Overview 5-1-1 Purpose of Chapter 5 This chapter explains LOGIQ V5/LOGIQ V3 system concepts, component arrangement, and subsystem function. Table 5-1 Contents in Chapter 5 Section Description Page Number Section 5-1...
  • Page 118: Block Diagram

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 5-2 Block Diagram 5-2-1 System Diagram Figure 5-1 LOGIQ V5/LOGIQ V3 System Diagram 5 - 2 Chapter 5 - Components and Functions (Theory)
  • Page 119: Common Service Platform

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 5-3 Common Service Platform 5-3-1 Introduction The Service Platform contains a set of software modules that are common to all PC backend ultrasound and cardiology systems. The Common Service Platform will increase service productivity and reduce training and service costs.
  • Page 120 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL This page was intentionally left blank. 5 - 4 Chapter 5 - Components and Functions (Theory)
  • Page 121: Overview

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Chapter 6 Service Adjustments Section 6-1 Overview 6-1-1 Purpose of this chapter 6 This section describes how to test and adjust the scanner. These tests are optional. You may use them to check the system for errors.
  • Page 122: Monitor Adjustments

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 6-2 Monitor Adjustments 6-2-1 Adjustments Procedures To adjust the brightness: Press Home and End button on the keyboard. Figure 6-2 Light Adjustment 6 - 2 Section 6-2 - Monitor Adjustments...
  • Page 123: Overview

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Chapter 7 Diagnostics/Troubleshooting Section 7-1 Overview 7-1-1 Purpose of Chapter 7 This section describes how to setup and run the tools and software that help maintain image quality and system operation. Very basic host, system and board level diagnostics are run whenever power is applied.
  • Page 124: Gathering Trouble Data

    Collect Vital System Information The following information is necessary in order to properly analyze data or images being reported as a malfunction or being returned to the manufacturer: Product Name = LOGIQ V5/LOGIQ V3 From the Utility>System>General>About screen: Applications Software...
  • Page 125: Collect A Trouble Image With Logs

    Power Supply Temperature NOTE: Power Supply and Temperature logs are not currently being updated by the LOGIQ V5/LOGIQ This Alt-D function is available at all times. Figure 7-1ALT-D Dialog Box When Alt-D is pressed, a menu box appears that allows for:...
  • Page 126: Screen Captures

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 7-3 Screen Captures There may be times when the operator or field engineer will want to capture a presentation on the screen. This is accomplished by first saving the image(s) to the clipboard using a Print Key.
  • Page 127: Capturing A Screen

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 7-3-3 Capturing a Screen The following is a generic process to capture any screen from the scanner: 1.) Navigate to and display the image/screen to be captured. 2.) Press Store. This will place a snapshot of the screen on the “clipboard” displayed at the bottom of the scan image display.
  • Page 128: Reset The Store Key To Customer's Functionality

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 7-3-3Capturing a Screen (cont’d) 6.) A Save dialog box will be opened. Choose d:\export folder as the archive location to save the image on the hard disk or CD. Figure 7-4 Save Dialog Box After capture the snapshot of the screen to the “clipboard”...
  • Page 129: Common Diagnostics

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 7-4 Common Diagnostics 7-4-1 Utilities Provides two selections: 7-4-1-1 Disruptive Mode Allows you to enable or disable disruptive mode troubleshooting. 7-4-1-2 System Shutdown Allows for system shutdown from the diagnostic menu. Select to Restart System or Shutdown System.
  • Page 130: Network Configuration

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 7-5 Network Configuration 7-5-1 Network Configuration 1.) Connect system with network. 2.) Enter Utility-> Connectivity-> TCP/IP, in IP settings window, check Enable DHCP, and select the proper network speed in Network Speed.
  • Page 131 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 7-5-1 Network Configuration (cont’d) 3.) Select Save, and a popup window displays. Select OK to restart the system and activate the changes. Figure 7-7 System Restart inquiry dialog 4.) After the system restarts, the network icon at the left bottom of screen turns green.
  • Page 132 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL This page was intentionally left blank. 7 - 10 Section 7-2 - Gathering Trouble Data...
  • Page 133: Overview

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Chapter 8 Replacement Procedures Section 8-1 Overview 8-1-1 Purpose of Chapter 8 This chapter describes replacement procedures for the following modules and subsystems. Table 8-1 Contents in Chapter 8 Section...
  • Page 134: Disassembly/Re-Assembly

    If the LOGIQ V5/LOGIQ V3 needs to be sent for repair, ensure that any patient information is erased from the Harddisk/Storage Device. In case that any patient information is still residing on the LOGIQ V5/ LOGIQ V3, GE will contact the customer and request for urgent collection of that patient information.
  • Page 135: Footrest

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 8-2-3 Footrest 8-2-3-1 Tools • Common phillips screwdrivers 8-2-3-2 Preparations • Shut Down the System and disconnect the power cord. 8-2-3-3 Removal procedure 1.) Unscrew 4 screws at the bottom side, and remove the footrest, refer to Figure 8-9 on page 8-3.
  • Page 136: Loading Base Image Software

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 8-3 Loading Base Image Software NOTE: While it is believed to be unnecessary, It would not hurt to disconnect the system from the network and remove all transducers. NOTE: Please ensure power cable is connected during system upgrade! 1.) Insert the USB disk labeled “System &...
  • Page 137 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 8-3 Loading Base Image Software (cont’d) 6.) Select one of the options for loading the system. Select choice 1] to load the complete disk. Figure 8-11 Selection for loading the system...
  • Page 138 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 8-3 Loading Base Image Software (cont’d) 8.) System will be loaded as shown in the screen below. Figure 8-13 System Load 9.) System updating finished, refer to Figure 8-14 on page 8-6.
  • Page 139: Overview

    ANUAL Chapter 9 Renewal Parts Section 9-1 Overview 9-1-1 Purpose of Chapter 9 This chapter gives you an overview of Renewal Parts for LOGIQ V5/LOGIQ V3. Table 9-1 Contents in Chapter 9 Section Description Page Number Overview List of Abbreviations...
  • Page 140: Renewal Parts Lists

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 9-3 Renewal Parts Lists 9-3-1 Equipment Models Covered in this Chapter Table 9-2 ACDC Power Pack & ACDC Power Cable list Part Name Part Number Description Quantity AC Power Cord...
  • Page 141: Operator Console Assy

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 9-4 Operator Console Assy Figure 9-1Operator Console Assy Chapter 9 - Renewal Parts 9 - 3...
  • Page 142: Cru Parts List

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 9-5 CRU Parts List A CRU is a FRU part that can be replaced by the Customer and Customer comfirms functional check at site. Table 9-3 CRU Parts List...
  • Page 143: Manuals

    Part Number Description 7000 5496012-100 LOGIQ V5/LOGIQ V3 Basic Service Manual System User Manuals 7001 5475853-100 LOGIQ V5/LOGIQ V3 Basic User Manual, English 7002 5475843-100 LOGIQ V5/LOGIQ V3 User Guide, English 7003 5475843-101 LOGIQ V5/LOGIQ V3 User Guide, French 7004...
  • Page 144 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 9-4 LOGIQ V Series Manuals Item Part Number Description 7032 5498971-141 LOGIQ V3 User Guide, Chinese 7033 5498972-141 LOGIQ V5 User Guide, Chinese 9 - 6 Section 9-3 - Renewal Parts Lists...
  • Page 146 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 9-5 LOGIQ V Model Designations Item Part Name Part Number 8013 1TB mobile USB HDD 5434317-3 Biopsy Kit 8014 E8C-RS biopsy kit E8385NA 8015 E8C-RS reusable biopsy kit 2398164...
  • Page 147: Probes

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 9-8Probes Table 9-6 Probes on LOGIQ V5/LOGIQV3 Item Part Name Part Number Description Quantity 9000 4C-RS 5451471 Probe (Center Frequency: 3.10MHz) 9001 3Sc-RS 47237516 Probe (Center Frequency: 2.75MHz) 9002...
  • Page 148 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL This page was intentionally left blank. 9 - 10 Section 9-8 - Probes...
  • Page 149: Overview

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Chapter 10 Care & Maintenance Section 10-1 Overview 10-1-1 Periodic Maintenance Inspections It has been determined by engineering that your system does not have any high wear components that fail with use, therefore no Periodic Maintenance Inspections are mandatory. Some Customers Quality Assurance Programs may require additional tasks and or inspections at a different frequency than listed in this manual.
  • Page 150: Why Do Maintenance

    The service procedures and recommended intervals shown in the Care & Maintenance Task Schedule assumes that you use your LOGIQ V5/LOGIQ V3 for an average patient load (10-12 per day) and not use it as a primary mobile unit which is transported between diagnostic facilities.
  • Page 151 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 10-3 Maintenance Task Schedule (cont’d) Table 10-2 Customer Care Schedule Per Facilities Service at Indicated Time Daily Weekly Monthly QA Program Notes • Clean Probe Holders more frequently depending on •...
  • Page 152: Tools Required

    Section 10-4 Tools Required 10-4-1 Standard GE Tool Kit The following is a description of the “Standard” GE tool kit in the USA. Not all tools are required for PMs. Table 10-3 Overview of GE-1 Tool Kit Contents Tool ID...
  • Page 153 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Table 10-3 Overview of GE-1 Tool Kit Contents (cont’d) Tool ID Description Tool ID Description 9-65283 Case 8.5 in. x 4.5 in. x 2 in. Deep 9-45072 Pliers 6 inch Diagonal...
  • Page 154: Special Tools, Supplies And Equipment

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 10-4-2 Special Tools, Supplies and Equipment 10-4-2-1 Specific Requirements for Care & Maintenance Table 10-5 Overview of Requirements for Care & Maintenance Tool Part Number Comments Digital Volt Meter (DVM)
  • Page 155: Input Power

    Physical Checks Step Item Description Verify that all system labeling is present and in readable condition. refer to the LOGIQ V5/LOGIQ V3 Labeling User Manual for details. Scratches & Dents Inspect the console for dents, scratches or cracks. Wheels & Brakes Check all wheels and casters for wear and verify operation of foot brake, to stop the unit from moving, and release mechanism.
  • Page 156: Outlet Test -Wiring Arrangement - Usa & Canada

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 10-4-6 Outlet Test -Wiring Arrangement - USA & Canada Test all outlets in the area for proper grounding and wiring arrangement by plugging in the neon outlet tester and noting the combination of lights that are illuminated. Any problems found should be reported to the hospital immediately and the receptacle should not be used.
  • Page 157: Grounding Continuity

    2.) Plug the unit into the meter, and the meter into the tested AC wall outlet. 3.) Plug the black chassis cable into the meter’s “CHASSIS” connector and attach the black chassis cable clamp to an exposed metal part of the LOGIQ V5/LOGIQ V3 unit. 4.) Set the meter’s “FUNCTION” switch to the RESISTANCE position.
  • Page 158: Chassis Leakage Current Test

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 10-4-8 Chassis Leakage Current Test 10-4-8-1 Definition This test measures the current that would flow in a grounded person who touched accessible metal parts of the bedside station if the ground wire should break. The test verifies the isolation of the power line from the chassis.
  • Page 159: Isolated Patient Lead (Source) Leakage–Lead To Lead

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 10-4-9 Isolated Patient Lead (Source) Leakage–Lead to Lead Reference the procedure in the IEC 60601-1. Select and test each of the five ECG lead positions (except ALL) on the LEAD selector, testing each to the power condition combinations found in the table.
  • Page 160 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 10-4-10-1 Data Sheet for ECG Leakage Current The test passes when all readings measure less than the value shown in the table below. Record all data on the PM Inspection Certificate.
  • Page 161: Probe Leakage Current Test

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 10-4-11 Probe Leakage Current Test 10-4-11-1 Definition This test measures the current that would flow to ground from any of the probes through a patient who is being scanned and becomes grounded by touching some other grounded surface.
  • Page 162 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL 10-4-11-5 Data Sheet for Transducer Source Leakage Current The test passes when all readings measure less than the values. Record all data on the PM Inspection Certificate. Equipment damage possibility. Never switch the Polarity and the status of Neutral when the unit CAUTION is powered ON.
  • Page 163: When There's Too Much Leakage Current

    LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Section 10-5 When There's Too Much Leakage Current... CHASSIS FAILS Check the ground on the power cord and plug for continuity. Ensure the ground is not broken, frayed, or intermittent. Replace any defective part.
  • Page 164 Air Filter Applicable Software Options Probe Holders Applicable Hardware Options External I/O Control Panel Wheels, Brakes & Swivel Locks Monitor Cables and Connectors GE Approved Peripherals (VCR, CD-RW, MOD, Touch Panel Printers) Measurement Accuracy GE Approved Peripherals COMMENTS: ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________...
  • Page 165 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL ELECTRICAL SAFETY Max Value Value Electrical Test Performed Allowed Measured Comments Outlet (correct ground &wiring config.) System Ground Continuity Chassis Source Leakage Current - Probe Chassis Source Leakage Current - Caster...
  • Page 166 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL This page was intentionally left blank. 10 - 18 Section 10-5 - When There's Too Much Leakage Current...
  • Page 167 LOGIQ V5/LOGIQ V3 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL INDEX Abbreviations, 9-1 Gathering Trouble Data, 7-2 Archiving Images General Cleaning, 10-7 Move, 4-28 Backup Patient Database, 4-25 Preset Configurations, 4-25 Hazard Icons, 1-6 Basic Measurements Human Safety, 1-10 Functional Checks, 4-22...
  • Page 168 PROPRIETARY TO GE 5496012-100, R IRECTION EVISION ASIC ERVICE ANUAL Touch Panel Functional Checks, 4-7 Trouble Image with Logs, 7-3 Troubleshooting Gathering Trouble Data, 7-2 Screen Captures, 7-4 Trouble Image with Logs, 7-3 Vital System Information, 7-2 Voltage Settings, 3-10...
  • Page 170 2014, General Electric Company. © GE-GEMedical Systems Ultrasound. 9900 Innovation Drive Wawautosa, Wisconsin 53226...

This manual is also suitable for:

Logiq v3

Table of Contents