Table of Contents
NW-미주향-AC 2010.6.8 3:48 PM 페이지59 in
TROUBLESHOOTING
4-2-12. No water supply to the ice maker.
Preliminary Inspection
1. Water supplies directly to water valve. Please shut off the water supplying prior to repair.
2. Power is applied to the one end of wires. Be careful when disassembling not to get an electric shock.
3. To check the Ice Water Valve operation, shall press the Ice Maker Test switch and then check the operation.
(Ice Maker in freezer)
☞ Checking method of voltage
Based on PCB common Ground REG1 Heater Sink
1) Check the voltage of IC71 #5 (Same voltage as IC10 #30)
-.when Ice Water valve operating (About 5V±0.5V)
Based on PCB common Ground REG1 Heater Sink
2) IC71 #14 voltage
-.When Ice Water valve waiting (About 12V±0.7V)
-.When Ice Water valve waiting (About 0.7V±0.5V)
3) Check the voltage of Ice Water Valve operation (AC Voltage)
=> For checking Relay RY74 operation.
CN72-#9(Red) ↔ CN71-#9(Purple)
-.When Ice Water valve waiting (About AC 0V)
-.When Ice Water valve operating (About AC 115V± 20%)
Common PCB Ground
REG1 Heater Sink
Main PCB normal
-- Need to check the other parts
① Check the wire between Ice Water Valve ↔ Main
PCB
② Ice Water Valve itself has trouble or bad contact
of connector.
③ Check the connection hose
Start
Is the confirming
sound of valve operation heard after pressing
the Ice Maker Test switch?
No
Does
Main PCB IC10 MICOM #30 have
HIGH(5V) output?
No
Does
Main PCB IC71 #14 have about 0.7V
output?
Yes
Is Main PCB RELAY
RY74 contact normal?
Yes
59
Yes
Normal (Check Ice Water Valve
connecting hose)
No
Check Cold solder joint Short/
Replace PCB
No
Check Cold solder joint Short/
Replace PCB
No
Check Cold solder joint Short/
Replace PCB
Table of Contents