To Remove Pressure Relief Valve, Flow Switch And Air Purge Valve; To Remove Water Pump - Panasonic WH-ADC0916G9E8 WH-UX09FE8 Service Manual

Hide thumbs Also See for WH-ADC0916G9E8 WH-UX09FE8:
Table of Contents

18.6 To Remove Pressure Relief Valve, Flow Switch and Air Purge Valve

When reinstall Flow Switch, ensure the arrow on the flow switch is parallel with the pipe shaft and is facing in
the direction of flow.
During reinstall Air Purge Valve.

18.7 To Remove Water Pump

2. Remove 2 screws from the water pump.
5. Turn the Air Purge Valve
anti-clockwise then remove.
Air Purge Valve
3. Pull outward to remove
Pressure Relief Valve.
2. Pull down to remove
water hose.
Make sure plug is fully close
in clockwise direction.
Apply some water based grease
on packing surface before fix
with shut off valve.
1. Disconnect CN-PUMP2 from
electronic controller.
1. Remove 2 retaining rings.
4. Turn the flow switch anti-clockwise
then remove Flow Switch.
Pressure Relief Valve
Packing
149
Flow Switch
Water Pump
3. Remove 2 retaining rings, then pull
out the Water Pump.

Hide quick links:

Table of Contents
loading

Table of Contents