Hitachi PH Instruction Manual page 41

Ink jet printer for industrial marking
Table of Contents
1-30 ● Connection of signals
1.5.3-3 Warning signal output
The following describes the wiring of the signal that is outputted to the outside for the
purpose of indicating that the IJ printer is in the warning mode.
(a) When using the NO contact (make contact)
Status indicator
lamp or the like
Power supply
(b) When using the NC contact (break contact)
Status indicator
lamp or the like
Power supply
For both the NO and NC contacts, the maximum capacities of the fault and warning
condition outputs are 30 VAC/0.5A, or 30 VDC/1 A. If any load having a greater
capacity is used, furnish a separate relay in between.
Further, if a motor, relay, or other inductive load is employed, a counterelectromotive
force may be generated to reduce the useful contact life.
Therefore, be sure to provide contact protection as suggested for the ready output
signal wiring.
TB2
7
NC
Warning state
Normal state
8
NO
9
COM
TB2
Warning state
Normal state
7
NC
8
NO
9
COM
8-9 contact
Closed
Open
7-9 contact
Open
Closed