26 | Adjusting the MAIN MENU
6
Adjusting the MAIN MENU
Detailed instructions on navigating through the
menu structure, programming, deleting settings
6.1
Overview and adjustment of the MAIN MENU
The tables set out below provide:
An overview of the menu structure (column 1).
•
The menu depth is identified by various
shades of grey.
For example, in menu Heating > Programme
submenus Edit and View are on the same
level.
An overview of the factory settings (column 2),
•
e.g. for the purposes of resetting individual
menu point to their factory settings.
An overview of the setting ranges of the
•
individual menu points (column 3).
Space for making a note of your personal
•
settings (column 4).
6.1.1 MAIN MENU: Holiday
Menu structure Holiday Factory setting
Start
End
Heating
Domestic hot water
DHW circulation pump
Thermal disinfection
1) DHW heating with combi boiler
2) DHW heating via DHW cylinder
6 720 645 349 (2010/09)
– – . – – . – – – –
– – . – – . – – – –
Frost
1)
Off
2)
15 °C
Off
Off
and resetting to the factory settings are provided
in chapter 5.2 starting on page 21.
A way to locate detailed descriptions regarding
•
the individual menu points (column 5).
The menu points are only shown if
the system components are present
and/or active, and if no remote
control is accessing them. Some
menu points are not shown because
they are switched off by a setting for
another menu point.
B Always set or skip menu points in
order. In that way, subsequent
menu points will be
automatically adjusted or not
shown.
Setting range
Today ... 31.12.2099
(in year/month/day steps)
Start date ... 31.12.2099
(in year/month/day steps)
Frost | Economy | Comfort | Auto
1)
Off | Auto | On
2)
15 °C ... 60 °C | Auto
Off | Auto | On
Off | On
Personal
Description
setting
frompage
31