The installation location must meet the following criteria:
General
Even and horizontal
Load-bearing (see device weight table)
No outside temperature under -20 °C
such as snow or water levels
The height difference of the liquid system circuit may not exceed 7 m
Easy access for maintenance work
Condensate must drain away easily
No damage to other objects if water leaks
If a solar installation is connected, the connection cable between
the solar pump station and the compact unit may not be longer than
10 metres
Minimum clearances
The minimum clearances (see Figure) must be observed.
1
3
Minimum clearances of the compact unit to adjacent walls and objects, indicating the air
Location / Installing the device
112 kg
153 kg
157 kg
155 kg
158 kg
n. a.
Minimum clearance
1
Minimum clearance
2
Minimum clearance 1,000 mm
3
2
2
Location
4
100 mm
300 mm
4 – 13