beautypg.com
Manuals
Brands
YOKOGAWA Manuals
Media Converter
EXA DO402G
YOKOGAWA EXA DO402G Manuals
Manuals and User Guides for YOKOGAWA EXA DO402G. We have
3
YOKOGAWA EXA DO402G manuals available for free PDF download: User Manual, Instruction Manual
YOKOGAWA EXA DO402G User Manual (103 pages)
Dissolved Oxygen Converter
Brand:
YOKOGAWA
| Category:
Media Converter
| Size: 8.49 MB
Table of Contents
Table of Contents
2
Preface
6
1 Introduction and General Description
8
Instrument Check
8
Application
9
General Information
10
Configuration Checklist for DO402
12
System Configuration
13
Dissolved Oxygen Sensor
13
The Holders
14
2 Do402G Specifications
16
General
16
Operating Specifications
17
Model and Suffix Codes
18
3 Installation and Wiring
20
Installation and Dimensions
20
Installation Site
20
Mounting Methods
20
Wiring
22
Preparation
23
Wiring the Power Supply
24
General Precautions
24
Access to Terminal and Cable Entry
25
AC Power
26
Grounding the Housing
26
Switching on the Instrument
26
Wiring the Contact Signals
27
General Precautions
27
Contact Outputs
27
Contact Input
27
Wiring the Analog Output Signals
28
General Precautions
28
Analog Output Signals
28
Wiring the Standard Galvanic Sensor
28
Wiring Other Galvanic Sensors
29
Wiring the Standard Optical Sensor (DO70G)
29
Wiring Polarographic Sensors
30
Wiring RS485 Signal
30
4 Operation; Display Functions and Setting
32
Operator Interface
32
Explanation of Operating Keys
33
Setting Passcodes
34
Display Functions (Default)
35
5 Parameter Setting
36
Maintenance Mode
36
Manual Activation of Hold
37
Manual Wash Start/Stop
38
Setpoint Adjustment
39
Commissioning Mode
40
Setpoints
41
Range
43
Hold
45
Wash
47
Service
48
Notes for Guidance in the Use of Service Coded Settings
49
Parameter Specific Functions
49
Temperature Functions
51
Calibration Functions
51
Ma Output Settings
53
Contact Outputs
55
User Interface
61
Communication Setup
63
General
63
Test and Setup Mode
63
6 Calibration Procedure
66
General
66
Calibration Methods
66
Diagnostic Functions Performed During Calibration
67
Calibration Procedure Using Air Calibration Method
67
Preparation
67
Procedure for Air Calibration
68
Calibration Procedure Using Water Calibration Method
69
Preparation
69
Calibration Operation (Water Calibration Method)
69
Procedure for Water Calibration
70
Calibration Method Using Manual Calibration Method
71
Preparation
71
Procedure for Manual Calibration
72
7 Maintenance
74
Overall Dissolvedoxygen Metering System
74
Inspection and Maintenance to be Implemented Periodically
74
Inspection and Maintenance to be Implemented on Occasion
74
Periodic Maintenance for the EXA DO402G Converter
75
Fuse Replacement
75
8 Troubleshooting
78
Measures in the Case of Converter Operation Failure
78
No Dissolved-Oxygen Converter Operation
78
Operation Key or Display Failure
78
Measures in the Case of Failure (Error) Detection
79
9 Spare Parts
82
10 Appendix
84
Setpoint
84
Range
84
Hold
84
Wash
84
User Setting Table
85
YOKOGAWA EXA DO402G User Manual (95 pages)
Dissolved Oxygen Converter [Style: S3]
Brand:
YOKOGAWA
| Category:
Media Converter
| Size: 3.4 MB
Table of Contents
Introduction
2
Safety Precautions
3
Warranty and Service
4
Table of Contents
6
1 Introduction and General Description
10
Instrument Check
10
Application
11
General Information
12
Configuration Checklist for DO402
15
System Configuration
16
Dissolved Oxygen Sensor
16
The Holders
17
2 DO402G Specifications
18
General
18
Power Supply
19
Operating Specifications
21
Model and Suffix Codes
22
3 Installation and Wiring
24
Installation and Dimensions
24
Installation Site
24
Mounting Methods
24
Wiring
27
Wiring of DO30G
27
Wiring of DO70G
28
Preparation
29
Wiring the Power Supply
30
General Precautions
30
Access to Terminal and Cable Entry
30
Grounding the Housing
32
Switching on the Instrument
33
Wiring the Contact Signals
33
General Precautions
33
Contact Outputs
33
Contact Input
34
Wiring the Analog Output Signals
34
General Precautions
34
Analog Output Signals
35
Wiring the Standard Galvanic Sensor
35
Wiring Other Galvanic Sensors
36
Wiring the Standard Optical Sensor (DO70G)
37
Wiring Polarographic Sensors
39
Wiring RS-485 Signal
39
4 Operation; Display Functions and Setting
40
Operator Interface
40
Explanation of Operating Keys
41
Setting Passcodes
42
Display Functions (Default)
43
5 Parameter Setting
44
Maintenance Mode
44
Manual Activation of Hold
45
Manual Wash Start/Stop
46
Setpoint Adjustment
47
Commissioning Mode
48
Setpoints
49
Range
51
Hold
53
Wash
55
Service
56
Notes for Guidance in the Use of Service Coded Settings
57
Parameter Specific Functions
57
Temperature Functions
58
Calibration Functions
59
Ma Output Settings
60
Contact Outputs
61
User Interface
65
Communication Setup
66
General
67
Test and Setup Mode
67
6 Calibration Procesure
68
General
68
Calibration Methods
68
Diagnostic Functions Performed During Calibration
69
Calibration Procedure Using Air Calibration Method
69
Preparation
69
Procedure For Air Calibration
70
Calibration Procedure Using Water Calibration Method
71
Preparation
71
Calibration Operation (Water Calibration Method)
71
Procedure for Water Calibration
72
Calibration Method Using Manual Calibration Method
73
Preparation
73
Procedure for Manual Calibration
74
7 Maintenance
78
Overall Dissolved Oxygen Metering System
78
Inspection and Maintenance to be Implemented Periodically
78
Inspection and Maintenance to be Implemented on Occasion
78
Periodic Maintenance for the EXA DO402G Converter
79
Fuse Replacement
79
8 Troubleshooting
82
Measures in the Case of Converter Operation Failure
82
No Dissolved-Oxygen Converter Operation
82
Operation Key or Display Failure
82
Measures in the Case of Failure (Error) Detection
82
9 Spare Parts
86
10 Appendix
88
Setpoint
88
Range
88
Hold
88
Wash
89
User Setting Table
89
Error Codes
90
Parts List
92
Revision Information
94
YOKOGAWA EXA DO402G Instruction Manual (82 pages)
Converter for Dissolved Oxygen
Brand:
YOKOGAWA
| Category:
Media Converter
| Size: 0.88 MB
Table of Contents
Table of Contents
3
Preface
5
Introduction and General Description
7
Instrument Check
7
Application
8
General Information
9
System Configuration
12
Dissolved Oxygen Sensor
12
The Holders
12
Do402G Specifications
13
General
13
Operating Specifications
15
Model and Suffix Codes
15
Installation and Wiring
17
Installation and Dimensions
17
Installation Site
17
Mounting Methods
17
Preparation
19
Wiring the Power Supply
20
General Precautions
20
Access to Terminal and Cable Entry
20
AC Power
21
DC Power
21
Grounding the Housing
21
Switching on the Instrument
21
Changing the Supply Voltage
22
Wiring the Contact Signals
22
General Precautions
22
Contact Outputs
22
Wiring the Analog Output Signals
23
General Precautions
23
Analog Output Signals
23
Wiring the Standard Galvanic Sensor
23
Wiring Other Galvanic Sensors
23
Wiring Polarographic Sensors
24
Tag Plate Mounting
24
Operation; Display Functions and Setting
25
Operator Interface
25
Explanation of Operating Keys
26
Setting Passcodes
27
Passcode Protection
27
Display Functions (Default)
28
Parameter Setting
29
Maintenance Mode
29
Manual Activation of Hold
30
Manual Wash Start/Stop
31
Setpoint Adjustment
32
Commissioning Mode
33
Setpoints
34
Range
36
Hold
38
Wash
40
Service
41
Notes for Guidance in the Use of Service Coded Settings
42
Parameter Specific Functions
42
Temperature Functions
44
Calibration Functions
46
Ma Output Settings
48
Contact Outputs
50
User Interface
54
Communication Setup
56
General
56
Test and Setup Mode
58
Calibration
61
General
61
Calibration Methods
61
Diagnostic Functions Performed During Calibration
62
Calibration Procedure Using Air Calibration Method
62
Preparation
62
Procedure for Air Calibration
63
Calibration Procedure Using Water Calibration Method
64
Preparation
64
Calibration Operation (Water Calibration Method)
64
Procedure for Water Calibration
65
Preparation
66
Procedure for Manual Calibration
67
Maintenance
69
Overall Dissolved Oxygen Metering System
69
Inspection and Maintenance to be Implemented Periodically
69
Inspection and Maintenance to be Implemented on Occasion
69
Periodic Maintenance for the EXA DO402G Converter
70
Troubleshooting
71
Measures in the Case of Converter Operation Failure
71
No Dissolved Oxygen Converter Operation
71
Operation Key or Display Failure
71
Measures in the Case of Failure (Error) Detection
72
Spare Parts
75
Appendix
77
Setpoint
77
Range
77
Hold
77
Wash
77
User Setting Table
78
Error Codes
81
Related Products
Yokogawa Exaxt450
YOKOGAWA EXAxt 450
YOKOGAWA EXAxt ZR Series
YOKOGAWA EXA SC202G
YOKOGAWA EXA SC202S
YOKOGAWA EXAxtZR
YOKOGAWA Dpharp vigilantplant EJA120A
YOKOGAWA Dpharp vigilantplant EJA130A
YOKOGAWA EJA438
YOKOGAWA DPharp EJA210
YOKOGAWA Categories
Measuring Instruments
Test Equipment
Transmitter
Controller
Media Converter
More YOKOGAWA Manuals