beautypg.com
Manuals
Brands
Vaillant Manuals
Water Heater
aroSTOR VWL B 270/5 UK
Vaillant aroSTOR VWL B 270/5 UK Manuals
Manuals and User Guides for Vaillant aroSTOR VWL B 270/5 UK. We have
3
Vaillant aroSTOR VWL B 270/5 UK manuals available for free PDF download: Installation And Maintenance Instructions Manual, Operating Instructions Manual
Vaillant aroSTOR VWL B 270/5 UK Installation And Maintenance Instructions Manual (32 pages)
Brand:
Vaillant
| Category:
Heat Pump
| Size: 1.4 MB
Table of Contents
Table of Contents
2
1 Safety
3
Action-Related Warnings
3
Intended Use
3
Risk Caused by Inadequate Qualifications
3
Risk of Death from Electric Shock
3
Risk of Death Due to Lack of Safety Devices
3
Risk of Death Due to Explosive and Flammable Materials
3
Risk of Being Burned or Scalded by Hot Components
4
Material Damage Due to Unsuitable Installation Surface
4
Risk of Injury Due to the Heavy Weight of the Product
4
Risk of Material Damage Caused by Frost
4
Risk of Material Damage Caused by Using an Unsuitable Tool
4
Risk of Material Damage Caused by Water that Is too Hard
4
Risk of Damage from Corrosion Caused by Unsuitable Room Air
4
Risk of Poisoning Caused by Insufficient Air Supply
4
Structural Damage Due to Escaping Water
4
Regulations (Directives, Laws, Standards)
5
2 Notes on the Documentation
6
Observing Other Applicable Documents
6
Storing Documents
6
Validity of the Instructions
6
3 Product Description
7
System Diagram
7
Product Design
8
Operation
8
Type Designation and Serial Number
8
CE Marking
8
Hot Water Association
8
4 Set-Up
9
Transporting the Product to the Installation Site
9
Carrying the Product
9
Unpacking the Product
9
Checking the Scope of Delivery
9
Product Dimensions and Connection Dimensions
10
Minimum Clearances
11
Requirements for the Installation Site
11
Removing/Installing the Protective Cover
11
5 Installation
11
Installing the Air Supply and Air Exhaust
12
Installing the Water Connections
14
Electrical Installation
16
6 Start-Up
16
Filling the Hot Water Circuit
16
Switching on the Product
17
7 Handing the Product over to the Operator 7
17
8 Adapting the Unit to the Installation
17
Calling up the Installer Level
17
Activating and Setting Photovoltaic Mode
17
Reading the Input Data
18
Setting the Anti-Legionella Function
18
Selecting the Load Relief Stage
18
Setting the Minimum Temperature
18
Setting Ventilator Mode
18
Setting the Maximum Heating Time
19
Reading the Meter Status
19
Locking the Control Elements
19
Checking the Immersion Heater
20
9 Troubleshooting
20
Eliminating Faults
20
Resetting Parameters to Factory Settings
20
Resetting the Safety Cut-Out
20
Replacing the Mains Connection Cable
21
Completing Repair Work
21
10 Inspection and Maintenance
21
Preparing the Maintenance and Repair Work
21
Observing Inspection and Maintenance Intervals
21
Draining the Product
21
Procuring Spare Parts
21
11 Decommissioning
21
Decommissioning the Product
21
Arranging Disposal of Refrigerant
21
12 Recycling and Disposal
22
Appendix
23
A Annual Inspection and Maintenance Work - Overview
23
B Fault Messages - Overview
23
C Installer Level - Overview
25
D Electronics Box Wiring Diagram
27
E Basic Hydraulic Diagram
28
F Heat Pump Output Curves
28
G Technical Data
29
Index
31
Vaillant aroSTOR VWL B 270/5 UK Installation And Maintenance Instructions Manual (36 pages)
Brand:
Vaillant
| Category:
Water Heater
| Size: 0.74 MB
Table of Contents
Table of Contents
2
Safety
3
Action-Related Warnings
3
Intended Use
3
General Safety Information
3
Regulations (Directives, Laws, Standards)
5
Notes on the Documentation
6
Observing Other Applicable Documents
6
Storing Documents
6
Validity of the Instructions
6
Product Description
6
Product Design
6
Operation
6
Basic System Diagram
7
Type Designation and Serial Number
8
CE Marking
8
Hot Water Association
8
Set-Up
8
Transporting the Product to the Installation Site
8
Carrying the Product
8
Unpacking the Product
9
Checking the Scope of Delivery
9
Product Dimensions and Connection Dimensions
9
Requirements for the Installation Site
9
Removing/Installing the Protective Cover
10
Installation
10
Installing the Air Supply and Air Exhaust
10
Installing the Water Connections
12
Electrical Installation
16
Start-Up
17
Checking and Preparing the Cold Water Supply
17
Filling the Domestic Hot Water Circuit
18
Switching on the Product
18
Handing the Product over to the Operator
18
Adapting the Unit to the Installation
18
Calling up the Installer Level
18
Activating and Setting Photovoltaic Mode
18
Reading the Input Data
19
Setting the Anti-Legionella Function
19
Selecting the Load Relief Stage
19
Setting the Minimum Temperature
20
Setting Fan Mode
20
Setting the Maximum Heating Time
20
Reading the Meter Status
20
Locking the Control Elements
20
Checking the Immersion Heater
21
Troubleshooting
21
Eliminating Faults
21
Resetting Parameters to Factory Settings
21
Resetting the Safety Cut-Out
21
Replacing the Mains Connection Cable
22
Completing Repair Work
22
10 Inspection and Maintenance
22
Preparing the Maintenance and Repair Work
22
Observing Inspection and Maintenance Intervals
22
Draining the Product
22
Procuring Spare Parts
22
Checking the Safety Group's Expansion Relief Valve and the Cylinder's Expansion Relief Valve
22
Checking the Pre-Charge Pressure of the Expansion Vessel
22
Checking the Inside of the Cylinder
23
11 Decommissioning
23
Decommissioning the Product
23
Arranging Disposal of Refrigerant
23
12 Customer Service
23
13 Recycling and Disposal
23
Appendix
24
A Annual Inspection and Maintenance Work - Overview
24
B Fault Messages - Overview
24
C Installer Level - Overview
27
D Electronics Box Wiring Diagram
28
E Heat Pump Output Curves
29
F Maximum Water Temperature
29
G Technical Data
30
Index
32
Vaillant aroSTOR VWL B 270/5 UK Operating Instructions Manual (24 pages)
Brand:
Vaillant
| Category:
Water Heater
| Size: 0.89 MB
Table of Contents
Table of Contents
2
1 Safety
4
Intended Use
4
Danger Caused by Improper Operation
4
Risk of Death Caused by Escaping Refrigerant
4
Risk of Death Due to Changes to the Product or the Product Environment
5
Risk of Burns Caused by Touching Hot Surfaces
5
Risk of Being Scalded by Hot Drinking Water
5
Preventing the Risk of Injury from Freezing as a Result of Touching Refrigerant
5
Risk of Injury and Material
6
Not Carried out at All
6
Risk of Damage from Corrosion Caused by Unsuitable Room Air
6
Dangers of Modifying Product Surroundings
6
Frost Damage Due to Insufficient Room Temperature
6
Avoid Environmental Damage Caused by Escaping Refrigerant
7
2 Notes on the Documentation
8
Observing Other Applicable Documents
8
Storing Documents
8
Validity of the Instructions
8
3 Product Description
8
Product Design
8
Overview of the Control Elements
8
Displayed Symbols
9
Type Designation and Serial Number
9
Information on the Data Plate
9
CE Marking
10
Hot Water Association
10
4 Function
10
Operating Concept
10
Switching on the Product
10
Setting the Language
11
Setting the Time
11
Domestic Hot Water Temperature Setting
11
Additional Domestic Hot Water Temperature Setting When a Photovoltaic Installation Is Connected
11
Programming Operating Times
12
Setting the Holiday Mode
13
Setting the Boost Mode
13
Setting Limp Home Mode
13
Activating the Anti-Legionella Function
13
Frost Protection Function
13
5 Troubleshooting
14
Detecting and Rectifying Faults
14
6 Maintenance and Care
14
Maintenance
14
Caring for the Product
14
Checking the Condensate Discharge Pipe and Tundish
14
7 Decommissioning
14
Temporarily Decommissioning the Product
14
Permanently Decommissioning the Product
14
8 Recycling and Disposal
14
Arranging Disposal of Refrigerant
15
9 Guarantee and Customer Service
15
Guarantee
15
Appendix
16
A Troubleshooting
16
B Optimising Energy Consumption
17
Using a Low Tariff and a Control Cable Connection
17
Using a Low Tariff Without a Control Cable Connection
18
Operating with a Fixed Electricity Tariff
19
C End User Level - Overview
20
Related Products
Vaillant aroSTOR VWL B 200/5 UK
Vaillant aroSTOR VWL B 270/5
Vaillant aroSTOR VWL BM 270/5
Vaillant aroSTOR VWL BM 200/5
Vaillant 0010007381
Vaillant 0010007383
Vaillant 0010007385
Vaillant 0010007387
Vaillant 0010019209
Vaillant 0010019210
Vaillant Categories
Boiler
Water Heater
Heat Pump
Thermostat
Air Conditioner
More Vaillant Manuals