Manuals and User Guides for Emerson Liebert NXL. We have
6
Emerson Liebert NXL manuals available for free PDF download: Installation Manual, Operation And Maintenance Manual, Product Specification/Installation Sheet
Emerson Liebert NXL Installation Manual (80 pages)
625-1100kVA, 1.0PF, 60Hz, Three-Phase, Single-Module & Multi-Module
Brand:
Emerson
| Category:
UPS
| Size: 11.85 MB
Table of Contents
Product Warranty Registration
2
Table of Contents
3
Important Safety Instructions
7
Save These Instructions
7
1 Mechanical Installation
9
Introduction
9
Preliminary Checks
9
Environmental Considerations
9
UPS Room
9
Storage
10
Positioning
10
Moving the Cabinets
10
Clearances
10
Raised-Floor Installations
11
Kick Plate Installation
11
Special Considerations for 1+N Parallel Systems
11
System Composition
11
Cable Entry
12
Figure 1 Cabinet Arrangement-Liebert NXL, Battery Cabinets, Maintenance Bypass Cabinet
12
2 Ups Electrical Installation
13
External Protective Devices
13
Power Cables
13
Sizing the Input Breaker Feeding a Liebert NXL UPS
14
Power Cable Connection Procedure
14
Figure 2 Cabinet Grounding Plates
15
Figure 3 Kick Plate and Filter Locations
15
Figure 4 Low-Voltage Cable Installation-Top Entry
15
Control Cable and Communication
16
Dry Contacts
16
Figure 5 External Interface Board Connections Layout
16
Table 1 UPS Input Dry Contacts
16
Table 1
16
Table 2 UPS Control Contacts with Battery Cabinet or Module Battery Disconnect
17
Table 3 UPS Control Contacts with Global Maintenance Bypass
17
Table 4 UPS Control Contacts to Remote Status Panel
17
Multi-Module Communication
18
Communication Board in System
18
Figure 6 Inter-Module Communication Board Wiring Diagram-Multi-Modules
19
Remote Input Breaker (RIB)
20
Figure 7 Remote Input Breaker Diagram
20
Table 6 RIB UV Coil, Aux. Contacts from UPS RIB CB Interface Board to Remote CB1
21
Inverter Output Breaker (IOB)
22
Figure 8 Remote Output Breaker Diagram
22
Table 7 Remote IOB Contacts from Remote Breaker to UPS IOB CB Interface Board
23
Digital LBS
24
Boards
24
Figure 9 Inter-Module Communication Board Wiring Diagram-Digital LBS
24
Configuring Neutral and Ground Connections
25
Four-Wire Input Connections
25
Figure 10 Grounding Diagram-Four-Wire Single-Module Systems
25
Three-Wire Input Connections
26
Figure 11 Grounding Diagram-Four-Wire Multi-Module Systems
26
Figure 12 Grounding Diagram-Three-Wire Single-Module Systems
27
Figure 13 Grounding Diagram-Three-Wire Multi-Module Systems
27
Preferred Grounding Configuration, Battery Systems
28
Multi-Module Systems
28
High-Resistance Ground Systems
28
3 Optional Equipment
29
Single-Module System Options
29
Battery Temperature Sensor
29
Matching Liebert NXL Battery Cabinet
29
Load Bus Synch
29
Remote Alarm Status Panel
29
Communication and Monitoring
29
Alber Monitoring System
29
4 Installation Drawings
30
Figure 14 Main Components, 625Kva Liebert NXL, N+1 Multi-Module Unit Without Static Bypass
30
Bypass
31
Figure 15 Main Components, 625Kva Liebert NXL UPS, SMS and 1+N Multi-Module Unit with Static
31
Figure 16 Outline Drawing, 625Kva Liebert NXL, N+1 Multi-Module Unit Without Static Bypass
32
Bypass
33
Figure 17 Outline Drawing, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with Static
33
Figure 18 Base Detail Drawing, 625Kva Liebert NXL, N+1 Multi-Module Unit Without Static Bypass
34
Figure 19 Base Drawing, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with Static Bypass
35
Figure 20 Input Terminal Detail, 625Kva Liebert NXL, N+1 Multi-Module Unit Without Static Bypass
36
Bypass
37
Figure 21 Input Terminal Detail, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with Static
37
Bypass (Continued)
38
Figure 22 Output Terminal Detail, 625Kva Liebert NXL, N+1 Multi-Module Unit Without Static
38
Figure 23 Output Terminal Detail, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with
39
Static Bypass, Continued
39
Figure 24 Shipping Split 625Kva Liebert NXL Without Static Bypass
40
Figure 25 Shipping Split 625Kva Liebert NXL Without Static Bypass (Continued)
42
Figure 26 Shipping Split, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with Static Bypass
44
Bypass, Continued
46
Figure 27 Shipping Split, 625Kva Liebert NXL, SMS and 1+N Multi-Module Unit with Static
46
Figure 28 02-806710- Fan Interface Board 1
47
Figure 29 Liebert NXL 1100Kva Conduit Entry Points-Input Layout
47
Figure 30 Liebert NXL 1100Kva Conduit Entry Points-DC Layout
48
Figure 31 Liebert NXL 1100Kva Conduit Entry Points-N+1 Output Layout
48
Figure 32 Liebert NXL 1100Kva Conduit Entry Points-SMS/1+N Output Layout
49
Figure 33 Main Components, 1+N Multi-Module or SMS with Static Bypass, 1100Kva UPS
50
Figure 34 Conduit Landing, 1100Kva UPS 1+N Multi-Module or SMS with Static Bypass
51
Figure 35 Main Components, 1100Kva UPS N+1 Multi-Module Without Static Bypass
52
Figure 36 Outline Drawing 1100Kva UPS N+1 Multi-Module Without Static Bypass
53
Figure 37 Liebert 1100Kva, Multi-Module System, Shipping Split-Power Wiring
54
Figure 38 Liebert NXL 1100Kva, Multi-Module System, Shipping Split-Interconnections between
55
Inverter and Bypass
55
Figure 39 Liebert NXL 1100Kva, Multi-Module System, Shipping Split-Control Wiring
56
Table 9 Interconnects for 1100Kva UPS Multi-Module Unit
57
Figure 40 Liebert NXL 1100Kva, Single Module System, Shipping Split-Power Wiring
59
Figure 41 Liebert NXL 1100Kva, Single Module System, Shipping Split-Interconnections between
60
Inverter and Bypass
60
Figure 42 Liebert NXL 1100Kva, Single Module System, Shipping Split-Control Wiring
61
Table 10 Interconnects for 1100KVA UPS Single Module Unit
62
Figure 43 Conduit Landing Drawing 1100Kva UPS N+1 Multi-Module Without Static Bypass
63
Figure 44 Terminal Details 1100Kva UPS, N+1 Multi-Module Without Static Bypass
63
Figure 45 Busbar Terminal Details, 1100Kva UPS, N+1 Multi-Module Without Static Bypass
64
Figure 46 Terminal Details, 1100Kva UPS, 1+N Multi-Module or SMS with Static Bypass
64
Figure 47 Busbar Terminal Details, 1100Kva UPS, 1+N Multi-Module or SMS with Static Bypass
65
Figure 48 Base Detail Drawing 1100Kva UPS 1+ N Multi-Module or SMS with Static Bypass
66
Figure 49 Base Detail Drawing 1100Kva UPS N+1 Multi-Module Without Static Bypass
67
Figure 50 Single-Input Wire Cabinet- 500 - 750Kva Only
68
5 Specifications
69
Table 11 Liebert NXL UPS Specifications
69
Table 12 Current Ratings-Rectifier Input
71
Table 13 Current Ratings-Bypass Input
71
Table 14 Current Ratings-Output
71
Table 15 Current Ratings-Battery
71
Figure 51 Inverter Overload Data
72
Figure 52 Rectifier Overload Data
73
Figure 53 Bypass Overload Data
74
Table 16 Recommended Conduit and Cable Sizes
75
Table 17 Recommended Lug Sizes
77
Table 18 Recommended Torque Values
77
Emerson Liebert NXL Operation And Maintenance Manual (72 pages)
60Hz, Three Phase Single-Module
Brand:
Emerson
| Category:
UPS
| Size: 4.53 MB
Table of Contents
Table of Contents
3
Important Safety Instructions
7
Save These Instructions
7
Battery Cabinet Precautions
8
General Description
8
Modes of Operation
8
Normal Mode
8
Figure 1 Typical UPS System One-Line Diagram
8
Bypass Mode
9
Battery Mode
9
Maintenance Bypass
9
Options
9
Features
11
Figure 2 Main Component Locations
11
1 Introduction
8
2 Operation
11
Figure 3 Main Display Screen, Typical
12
Figure 4 MIMIC Display
12
Figure 5 Monitor/MIMIC Display Example: Normal Power Flow
13
Figure 6 Monitor/MIMIC Display Example: Utility Fail
13
Figure 7 Monitor/MIMIC Display Example: Load on Bypass, UPS on
14
Figure 8 Monitor/MIMIC Display Example: Load on Bypass, UPS Module off
14
Touchscreen Navigation
15
Main Display Screen
15
Figure 9 Menu Tree
15
Configurations Menu
16
Figure 10 Rating Parameters
16
Figure 11 System Settings Parameters
17
Figure 12 Adjustable Setpoints Parameters
18
Figure 13 Battery Management Parameters
19
Status Reports Menu
20
Startup Menu
20
Figure 14 Typical Event Management Parameters
20
Shutdown Menu
21
Figure 15 Shutdown Menu
21
Figure 16 UPS Shutdown Popup
21
Figure 17 System Shutdown Popup
21
Transfer Menu
22
Figure 18 Transfer/Retransfer Commands
22
Battery Management Menu
23
Figure 19 Time Remaining Display
23
Figure 20 Battery Cycle Monitor
24
Figure 21 Battery Cycle Monitor Summary
24
Metering
25
Help
25
2.2.10 Reset
25
2.2.11 Silence
25
Modes of Operation
25
Figure 22 Battery Cycle Monitor-Clear Log
25
Figure 23 Load on Bypass (UPS Not Available)
25
Load on Bypass
25
Figure 24 Load on Bypass, UPS Available
26
Figure 25 Load on UPS, Bypass Available
26
OK to Transfer
26
Figure 26 Input Power Fail, Load on Battery
27
Input Power Failure-Load on Battery
27
Emergency Module off
28
Figure 27 Load on UPS, Battery Not Available
28
Figure 28 Emergency Modules off
28
Off Battery
28
Figure 29 Remote Emergency Power off
29
Remote Emergency Power off
29
Startup Procedure
30
Figure 30 Startup Commands
31
Figure 31 UPS with Two-Breaker Bypass Cabinet
32
Load Transfer Procedures
32
Maintenance Bypass Load Transfers
32
Manual Procedures
29
Automatic Operations
34
Overloads (Without Transfer)
34
Automatic Transfers to Bypass (Overload Condition)
35
Figure 32 Current-Versus-Time Curves of Overload Capacity
35
Automatic Transfers to Bypass, UPS System Faults
36
Automatic Retransfers to UPS
36
Shutdown Procedures
34
Module Shutdown Procedure
34
3 Maintenance
37
Safety Precautions
37
Liebert Services
38
Professional Startup
38
Routine Maintenance
38
Record Log
39
Air Filters
39
Limited Life Components
40
Battery Maintenance
40
Table 1 UPS Component Service Life
40
Battery Safety Precautions
41
Table 2 Battery Voltage, Nominal and Float
42
Table 3 Battery Retorque Values
42
Torque Requirements
43
Detecting Trouble
43
Table 4 Torque Specifications, Unless Otherwise Labeled
43
Corrective Actions
44
Reporting a Problem
44
Upstream Feeder Circuit Breaker Setting Inspections
44
Battery Operation
45
Environmental Conditions
45
4 Specifications
45
Table 5 Environmental Specifications
45
Table 6 Electrical Specifications
46
Appendixa - Ups Alarm and Status Messages
49
Table 7 Liebert NXL Alarm and Status Messages
49
Emerson Liebert NXL Installation Manual (56 pages)
500-750, 60Hz, Three-Phase, Single-Module & Multi-Module
Brand:
Emerson
| Category:
UPS
| Size: 3.76 MB
Table of Contents
Product Warranty Registration
2
Table of Contents
3
Important Safety Instructions
7
Save These Instructions
7
1 Mechanical Installation
9
Introduction
9
Preliminary Checks
9
Environmental Considerations
9
UPS Room
9
Storage
10
Positioning
10
Moving the Cabinets
10
Clearances
10
Floor Installation/Anchoring
10
System Composition
11
Cable Entry
11
Figure 1 Cabinet Arrangement-Liebert NXL, Battery Cabinets, Maintenance Bypass Cabinet
11
2 Ups Electrical Installation
12
External Protective Devices
12
Power Cables
12
Power Cable Connection Procedure
13
Figure 2 Cabinet Grounding Plates
14
Figure 3 Kick Plate and Filter Locations
14
Figure 4 Low-Voltage Cable Installation-Top Entry
14
Control Cable and Communication
15
Figure 5 External Interface Board Connections Layout
15
Dry Contacts
16
Table 1
16
Table 2 UPS Control Contacts with Battery Cabinet or Module Battery Disconnect
16
Table 3 UPS Control Contacts with Maintenance Bypass
16
UPS Input Dry Contacts
16
Analog Load Bus Synch Connection to Non-Liebert NXL Equipment
17
Table 4 UPS Control Contacts to Remote Status Panel
17
Table 5 UPS Control Contacts with Analog LBS
17
Multi-Module Communication
19
Communication Board in System
19
Parallel from UPS Module Inter-Module Communication Board to Other Inter-Module
19
Table 6
19
Figure 6 Inter-Module Communication Board Wiring Diagram-Multi-Modules
20
Figure 7 Remote Input Breaker Diagram
20
Remote Input Breaker (RIB)
20
Table 7 RIB UV Coil, Aux. Contacts from UPS RIB CB Interface Board to Remote CB1
21
Figure 8 Remote Output Breaker Diagram
22
Inverter Output Breaker (IOB)
22
Digital LBS
23
Boards
23
Table 8 Remote IOB Contacts from Remote Breaker to UPS IOB CB Interface Board
23
Configuring Neutral and Ground Connections
24
Four-Wire Input Connections
24
Figure 9 Inter-Module Communication Board Wiring Diagram-Digital LBS
24
Three-Wire Input Connections
25
Preferred Grounding Configuration, Battery Systems
25
Multi-Module Systems
25
3 Optional Equipment
26
Single-Module System Options
26
Matching Maintenance Bypass Cabinet
26
Battery Temperature Sensor
26
Matching Liebert NXL Battery Cabinet
26
Matching Module Battery Disconnect-MBD
26
Load Bus Synch
26
Remote Alarm Panel
26
Communication and Monitoring
26
Alber Monitoring System
26
4 Installation Drawings
27
Figure 10 Main Components, 500Kva Liebert NXL 1+N Multi-Module or SMS with Static Bypass
27
Figure 11 Outline Drawing, Liebert NXL 500Kva UPS 1+N Multi-Module or SMS with Static Bypass
28
Figure 12 Output Terminal Details, Pg. 1, Liebert NXL 500Kva UPS 1+N Multi-Module or SMS with
29
Static Bypass
29
Figure 13 Output Terminal Details, Pg. 2, Liebert NXL 500Kva UPS 1+N Multi-Module or SMS with
30
Static Bypass
30
Figure 14 Base Drawing, Liebert NXL 500Kva UPS 1+N Multi-Module or SMS with Static Bypass
31
Figure 15 Main Components, 750Kva Liebert NXL UPS Without Static Bypass
32
Figure 16 Main Components, 750Kva Liebert NXL UPS with Static Bypass (SMS or 1+N)
33
Figure 17 Outline Drawing, 750Kva Liebert NXL Without Static Bypass
34
Figure 18 Outline Drawing, 750Kva Liebert NXL 1+N Multi-Module or SMS with Static Bypass
35
Figure 19 Base Detail Drawing, 750Kva Liebert NXL, N+1 Multi-Module Without Static Bypass
36
Figure 20 Base Drawing, 750Kva Liebert NXL 1+N Multi-Module or SMS with Static Bypass
37
Figure 21 Input/Output Terminal Detail, 750Kva Liebert NXL Without Static Bypass
38
Figure 22 Detail 750Kva Liebert NXL with Static Bypass (SMS/1+N)
39
Figure 23 Input/Output Terminal Detail, 750Kva Liebert NXL Without Static Bypass (Continued)
40
1+N) Continued
41
Figure 24 Input/Output Terminal Detail, 750Kva Liebert NXL with Static Bypass
41
Figure 25 Shipping Split 750Kva Liebert NXL Without Static Bypass
42
Figure 26 Shipping Split, 750Kva Liebert NXL with Static Bypass (SMS/1+N)
43
Figure 27 Shipping Split, 750Kva Liebert NXL with Static Bypass (SMS/1+N) Continued
44
Figure 28 Single-Input Wire Cabinet
45
Figure 29 Control Cable Layout, UPS Active Analog Load Bus Sync, 250-750Kva Units
46
Figure 30 Control Cable Layout, UPS Passive Analog Load Bus Sync, 250-750Kva Units
46
Figure 31 Control Cable Layout, UPS Analog Load Bus Sync, ELBS, 250-750Kva Units
47
5 Specifications
48
Table 10 Liebert NXL UPS Specifications
48
Table 11 Current Ratings-Rectifier Input
50
Table 12 Current Ratings-Bypass Input
50
Table 13 Current Ratings-Output
50
Table 14 Current Ratings-Battery
50
Table 15 Recommended Conduit and Cable Sizes
51
Table 16 Recommended Lug Sizes
52
Table 17 Recommended Torque Values
52
Emerson Liebert NXL Installation Manual (48 pages)
Battery System
Brand:
Emerson
| Category:
UPS
| Size: 3.67 MB
Table of Contents
Battery System
1
Product Warranty Registration
2
Table of Contents
3
Important Safety Instructions
5
Save These Instructions
5
1 Mechanical Installation
7
Introduction
7
Preliminary Checks
7
Environmental Considerations
7
Battery Room
7
Storage
7
Positioning
8
Moving the Cabinets
8
Clearances
9
Raised Floor Mounting
9
System Composition
9
Figure 1 Shipping Bolts
9
2 Battery Installation
10
Safety
10
Layout
10
Figure 2 Battery Cabinets Connected, Attached to UPS
11
Figure 3 Battery Cabinets Connected, Detached from UPS
11
Figure 4 Battery Cabinets Connected, with Module Battery Disconnect, Attached to UPS
12
Figure 5 Battery Cabinets Connected, with Module Battery Disconnect, Detached from UPS
12
Figure 6 Battery Cabinets Connected, Detached from Module Battery Disconnect, Detached from UPS
13
Figure 7 Stand-Alone Battery Cabinets, with Module Battery Disconnect, Detached from UPS
13
Cable Entry
14
Power Connection
14
Connected System
14
Stand-Alone System
14
Attached/Detached System
14
Figure 8 Stand-Alone Battery Cabinets, no Module Battery Disconnect, Detached from UPS
14
MBD Voltage Sense Leads
15
Grounding
15
Control Connection
15
Figure 9 Wiring External Interface Board in UPS to Battery Interface Board in Battery Cabinet
16
Figure 10 Control Cable Layout-Liebert NXL UPS to Liebert NXL Battery Cabinet
17
Alber Monitoring System-Optional
18
External Battery Room Temperature Sensor-Optional
18
Figure 11 Battery Temperature Sensor Control Connection
18
3 Installation Drawings
19
Figure 12 Outline Drawing, Liebert Battery Cabinet
19
Figure 13 Main Components, Liebert Battery Cabinet
20
Figure 14 Terminal Details, Liebert Battery Cabinet
21
Figure 15 Outline Drawing, 250-400Kva, Liebert Module Battery Disconnect
22
Figure 16 Terminal Detail Drawing, Liebert Module Battery Disconnect
23
Figure 17 Outline Drawing, 500-750Kva, Liebert Module Battery Disconnect
24
Figure 18 Wide Junction Cabinet Terminal Wiring
25
Figure 19 Liebert NXL Narrow Junction Cabinet-Terminal Detail and Outline Drawing
26
Figure 20 Liebert NXL Battery Cabinet Control Wiring
27
Figure 21 Liebert NXL Module Battery Disconnect Control Wiring
28
Figure 22 Voltage Sense Wire Harness Top Input and Bottom Input
29
Figure 23 Liebert NXL Module Battery Disconnect CAN Wire Harness Connection
30
Figure 24 Attached Battery Cabinet Connections
31
Figure 25 Ground Strap Location for Connected Cabinets
31
Figure 26 Battery Cabinet Interconnection Wiring to 250-400Kva UPS
32
Table 1 Liebert-Supplied Interconnect Wiring
32
Figure 27 Liebert NXL Module Battery Disconnect Interconnect Wiring to 250-400Kva UPS
33
Table 2 Liebert-Supplied Interconnect Wiring
33
Figure 28 Liebert NXL Battery Cabinet Interconnect Wiring to Liebert NXL Junction Cabinet
34
Figure 29 Liebert NXL UPS to Liebert NXL Module Battery Disconnect to Wide Liebert NXL
35
Junction Cabinet
35
Table 3 Liebert-Supplied Interconnect Wiring
35
Table 4 Liebert-Supplied Interconnect Wiring
35
Battery Cabinet
36
Figure 30 Liebert NXL UPS to Liebert NXL Module Battery Disconnect to Liebert NXL
36
Table 5 Liebert-Supplied Interconnect Wiring
36
Figure 31 Alber Battery Monitoring Connections
37
Figure 32 Battery Interface Board Wiring to Multiple Battery Cabinets
38
Figure 33 Alber Battery Monitoring Assembly Diagram
39
Table 6 Alber Battery Monitoring Assembly Connections
39
Figure 34 Alber Battery Monitoring Transformer Location and Battery Configuration
40
Table 7 Liebert NXL Battery Cabinet Specifications
41
Table 8 Liebert NXL Module Battery Disconnect Cabinet
42
Table 10 Alber Battery Monitoring Option Specifications
43
Table 11 Currents for Liebert NXL Module Battery Disconnect Cabinet
43
Table 9 Liebert NXL Junction Cabinet Specifications
43
Junction Cabinets
44
Table 12 Battery Cabinet Internal Breaker Selection Based on 5 Min EOD, Amps
44
Table 13 Liebert NXL Battery Cabinet Approximate Weights
44
Table 14 Approximate Weights, Liebert NXL Module Battery Disconnect and Liebert NXL
44
Table 15 Recommended Conduit and Cable Sizes for Liebert NXL Module Battery Disconnect
45
Table 16 Battery Torque Values
45
Table 17 Torque Specifications, Unless Otherwise Labeled
45
Emerson Liebert NXL Installation Manual (28 pages)
1600A-5000A, 60Hz, Three-Phase
Brand:
Emerson
| Category:
UPS
| Size: 1.35 MB
Table of Contents
Product Warranty Registration
2
Table of Contents
3
Important Safety Instructions
5
Save These Instructions
5
1 Mechanical Installation
7
Introduction
7
Preliminary Checks
7
Bypass Backfeed Breaker
7
Neutral Connections
7
Static Switch Installation
8
Figure 1 Static Switch Installation
8
Figure 2 Static Switch Installation, Steps 1 through 3
9
Figure 3 Static Switch Installation, Steps 4 through 10
9
2 Control Cable Connections and Communication
10
Dry Contacts
10
Figure 4 External Interface Board Connections Layout
10
Table 2 SCC Control Contacts with Maintenance Bypass
11
Table 3 SCC Control Contacts to Remote Alarm Status Panel
11
Multi-Module Communication
12
Remote Input Breaker (RIB)
13
Figure 5 Inter-Module Communication Board Wiring Diagram-Multi-Modules
13
Figure 6 Remote Input Breaker Diagram
13
Inverter Output Breaker (IOB)
14
Table 5 RIB UV Coil, Aux. Contacts from SCC RIB CB Interface Board to Remote CB1
14
Figure 7 Remote Output Breaker Diagram
15
Table 6 Remote IOB Contacts from Remote Breaker to SCC IOB CB Interface Board
15
Digital LBS
16
Figure 8 Inter-Module Communication Board Wiring Diagram-Digital LBS
16
Input Contact Isolator Board
17
Figure 9 Input Contact Isolator Dialog Box
17
Figure 10 Optional Input Contact Isolator Board
18
Table 8 Input Contact Isolator Board Pre-Assigned Values
18
Table 9 Input Contact Isolator Board Control Wiring Connections
18
Programmable Relay Board
19
Figure 11 Control Wiring, Programmable Relay Board
19
Table 10 Programmable Relay Board Pinout
19
Configuring the Programmable Relay Board Settings
20
Figure 12 Programmable Relay Board Dialog Box
20
3 Installation Drawings
21
Figure 13 Control Wiring Layout for Liebert NXL SCC
21
Figure 14 Main Components, Liebert NXL SCC Ebox
22
4 Specifications
23
Table 11 Liebert NXL Scci Bypass Static Switch and Ebox Specifications
23
Table 12
24
Table 12 UPS Current Ratings-Output
24
Table 13 UPS Current Ratings-Rectifier Input
24
Emerson Liebert NXL Product Specification/Installation Sheet (4 pages)
Brand:
Emerson
| Category:
Industrial Electrical
| Size: 0.27 MB
Related Products
Emerson Liebert NX
Emerson Liebert NXL series
Emerson Liebert NX Series
Emerson Liebert NXr
Emerson Liebert FPC
Emerson Liebert GXT
Emerson Liebert ITA
Emerson Liebert PowerSure PSP
Emerson Liebert HiPulse E Series
Emerson Liebert eXM
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals