Daikin RHYHBH08AAV3 manual available for free PDF download: Service Manual
Daikin RHYHBH08AAV3 Service Manual (170 pages)
Brand:
Daikin
| Category:
Boiler
| Size: 9.41 MB
Table of Contents
Error Codes: Outdoor Units 1
4
Table of Contents
4
Overview of General Problems 4
55
Equipment Does Not Operate
56
Indoor Pump Operates, but Compressor Does Not
57
Cooling/Heating Operation Starts but Stops Immediately
59
After Unit Shuts Down, It Cannot be Restarted for a While
61
Equipment Produces Loud Noise or Shakes
63
The Unit Is Turned on but the Compressor Is Not Starting
67
Pump Is Making Noise (Cavitation)
68
The Water Pressure Relief Valve Opens
69
The Water Pressure Relief Valve Leaks
70
The User Interface Does Not Display Certain Screens
71
Domestic Hot Water Capacity Shortage at Low Outdoor Tem
72
Space Heating Capacity Shortage at Low Outdoor Tempera
73
Room Temperature Set Point IsnT Reached or Increases too
74
Error Codes: Outdoor Units
103
X93;E1 Outdoor Unit PCB Abnormality
103
X93;E3 Abnormal High Pressure (Detected by the HPS)
104
X93;E4 Actuation of Low Pressure Sensor
106
X93;E5 Compressor Motor Lock
109
X93;E7 Malfunction of Outdoor Unit Fan Motor
111
X93;E9 Malfunction of Electronic Expansion Valve
114
X93;F3 Malfunctioning in Discharge Pipe Temperature
117
X93;H3 Malfunctioning HPS System
119
X93;H9, J3, J5, J6, J7, J8 Thermistor or Related Abnormality (Outdoor Unit)
121
X93;J1 Malfunction of Pressure Sensor
122
X93;L1 Faulty Outdoor PC Board
124
X93;L4 Radiation Fin Temperature Increased
126
X93;L5 DC Output Overcurrent (Instantaneous)
128
X93;L8 DC Output Overcurrent (Instantaneous)
130
X93;L9 Stall Prevention (Time Lag)
132
Pcb)
134
X93;Lc Malfunction of Transmission System
134
X93;P1 Open Phase or Power Supply Voltage Imbalance
136
X93;P4 Malfunction of Radiator Fin Temperature Thermistor
137
X93;Pj Malfunction of Radiator Fin Temperature Thermistor
138
Error Codes: System Malfunctions
139
X93;U0 Gas Shortage (Malfunction)
139
X93;U2 Abnormal Power Supply Voltage
141
X93;U3 Underfloor Heating Screed Dry-Out Failure
143
X93;U4 Malfunction of Transmission between Hydro-Box and Outdoor Unit
144
Shortage
146
X93;Uf Malfunction of Transmission between Hydro-Box and Outdoor Unit or Gas
146
X93;U5 Malfunction of Transmission between Hydro-Box and Remote Controller
148
X93;Ua Indoor-Outdoor Combination Problem
149
Additional Checks for Troubleshooting
150
Check No.1 - Outdoor Unit: Checking the Installation Condition
150
Check No.2 - Outdoor Unit: Checking the Expansion Valve
151
Check No.3 - Checking the Thermistors
152
Check No.4 - Resistance Conversion Table (Ambient, Coil, Fin)
153
Check No.5 - Resistance Conversion Table (Discharge Pipe Sensor)
155
Check No.6 - Evaluation of Abnormal High Pressure
156
Check No.7 - Evaluation of Abnormal Low Pressure
157
Check No.8 - Clogged Points
158
Check No.10 - Outdoor Unit: Fan Speed Pulse
159
Check No.11 - Outdoor Unit: Check for Power Transistor
160
Check No.13 - Check for Inadequate Refrigerant
161
Check No.14 - Check for Excessive Refrigerant Charging
162
Check No.15 - Check for Factors Causing Wet Operation
163
Check No.16 - Troubleshooting Yonos para Inverter Pump (Only for EH/VB004-008)
164
Repair
165
Tips and Tricks
166
Maintenance
167
Maintenance
168
Maintenance Schedule
168
Related Products
Daikin RHYHBH05AAV3
Daikin Rotex RHOB12AAV1H
Daikin Rotex RHOB18AAV1H
Daikin Rotex RHOB42AAV1H
Daikin RHOBG12AAV1
Daikin RHOBG18AAV1
Daikin Rotex RHOB12AAV1
Daikin Rotex RHOB18AAV1
Daikin Rotex RHOB42AAV1
Daikin RHYHBX08AAV3
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals