  • Page 1 ChloroMatic ® Salt Water Pool System Installation & Operating Instructions Models MCS16C MCS16CTP MC16C MCS24C MCS24CTP MC20C MCS36C MCS36CP MC30C MCS40C MCS50C Please pass these instructions on to the operator of this equipment. Email: [email protected] davey.com.au...
  • Page 2: Table Of Contents

    ChloroMatic ® Salt Water Pool System Congratulations! You are now the proud owner of the renowned ChloroMatic Salt ® Water Chlorinator.Please read all information in this manual carefully before installing or operating your ChloroMatic Salt Water Pool Chlorinator. ® Table of Contents Packing List ................................
  • Page 3: Important Notice

    IMPORTANT NOTICE FACTORS THAT WILL IMPROVE THE PERFORMANCE AND LIFE OF YOUR SALT WATER CHLORINATOR PLEASE READ THIS BEFORE OPERATING YOUR CHLORINATOR POOL BUILDERS: Please cover this information with your customer during the new pool “Hand over Session” Salt Water Chlorinators are a valuable piece of pool sanitising equipment and must be cared for to get the best performance and life span from it.
  • Page 4: Installation Instructions

    Note: The Chlorinator is not intended for use by young children or infirm persons without supervision. Please ensure that young children are supervised to ensure that they do not play with the Chlorinator. Power connections and wiring must be carried out by an authorised electrician. INSTALLATION INSTRUCTIONS FOR CHLOROMATIC (ESR and ESC) ®...
  • Page 5: Pre Start Up Procedure

    CONNECTING THE ELECTROLYTIC CELL TO THE POWER SUPPLY: The Power Supply is fitted with a flexible lead terminated with brass connectors. These must be correctly fitted to the connections on the inside of the Cell Head. To prevent incorrect connection the fittings have been colour coded. Black to Black & White to White ESC / Either Black Terminal ESCpH The Blue Gas Sensor connector should be pushed onto the thread of the small bolt. The power outlet on the bottom of the Power Supply is dedicated to the POOL PUMP ONLY.
  • Page 6 OPERATION LED’S CONTROL PANEL LAYOUT WINTER MODE SWITCH SANITISER OUTPUT DIAL TIME CLOCK SELECTOR SWITCH OPTIONAL POOL LIGHT SWITCH Once the salt level in the pool is correct the unit may be switched on. Set Sanitiser Output to Max (100%). The STAND - BY indicator will be On and no Cell Output will be seen for approx 30 seconds, this allows the pump and filter to prime and the Cell Housing to fill with water. After this start - up delay, the display should show 100 (ESR Models (+/-2), unless in Winter Mode where it will display 85 (ESR Models (+/-2). At this...
  • Page 7: Esr, Esc And Escph Series Features

    ChloroMatic MODEL ESR, ESC and ESCpH SERIES FEATURES: ® STAND- BY: The Stand - By indicator will be On when the Unit is preparing to produce sanitiser. This will be either during the systems initial start up or when the Cell has been turned Off during the filtration cycle. FLOW: If there is a problem with water flow or gas is detected in the Cell Housing the fIow indicator will be On. When this occurs the pump or pipes should be inspected for damage and the Flow Sensor connection checked. SANITISER OUTPUT CONTROL: The Sanitiser Output Control varies the amount of time the Cell operates during the filtration cycle.
  • Page 8: Automatic Time Clock Operation

    There are other factors that can cause the Unit not to work correctly: 1. Heavy Rain - can cause very diluted pool water to pass over the Cell due to surface skimming. 2. Scaled Cell - a scaled Cell will not draw as much electrical current as a clean Cell when first started. 3. Cold Water - cold pool water reduces the ability of a Cell to carry electrical current. (Refer Winter Mode below). 4. Failing Cell - as the Cell ages there will come a time when the electrical current draw will drop. This can be compensated for with the addition of extra salt.
  • Page 9 Selector Function Switch Functions and Instructions Description Position Set the current time on the digital clock. Select the Set Clock position on the selector switch to enable the time of day to be input. A number ‘1’ will appear at the left of the screen. Set Clock (a) The display will flash on and off as long as the selector switch remains at this position.
  • Page 10: Optional Pool Light Transformer

    Over-rides automatic time clock, Filtration System switched off. Auto- Filtration System switches on and off automatically according to times set. OPTIONAL POOL LIGHT TRANSFORMER: Power connections and wiring must be carried out by an authorised electrician. Your Davey ChloroMatic ® is fitted with one of two types of pool light transformer connections as follows:- TYPE 1: TERMINAL BLOCK CONNECTION BEHIND COVER PANEL BELOW DOOR (a) 12V – Operates only 12 volt lights.
  • Page 11 MAINTENANCE OF ELECTROLYTIC CELL: The cell is composed of precious materials, and although proper maintenance can prolong its life to the maximum, eventually the process of electrolysis will wear away its delicate coating, at which time it gradually ceases to produce chlorine.
  • Page 12: Day To Day Operation

    METHOD 2 As an alternative, an approved commercial Cell cleaning solution can be used a number of times effectively. WARNING: Follow safety instructions provided with the Hydrochloric Acid or cleaning solution. When handling Hydrochloric Acid, the use of eye protection, mask and gloves are highly recommended. Extreme caution should be taken whenever handling Hydrochloric Acid or Cell Cleaning Solution.
  • Page 13: Chlorine Production

    Salt is NOT used up in the process of producing chlorine or by evaporation. Salt is only lost through back - washing, splash - out, overflow or by leakage from the pool or plumbing. Winter rains can dilute the salt solution in your pool; therefore salt levels should be checked during this season. In colder water, the ChloroMatic should be set to Winter Mode. (Refer Winter Mode page 8). Low salt levels will destroy the coating on the Anode plates and will void all Warranty. The ChloroMatic has built in warning indicators to minimise damage resulting from insufficient salt levels, ®...
  • Page 14: General Information

    The appropriate chlorinator size for your pool is dependent on the local climate and the bather load of the NOTE: pool. Please note that chlorinator cell life can be increased with shorter running times during winter and lower output settings. Davey recommends that a chlorinator is run for between 6 - 8 hours a day during summer, and 4 hours during winter. GENERAL INFORMATION: RECOMMENDED POOL WATER CHEMISTRY Stabiliser –...
  • Page 15: Important Notes

    IMPORTANT NOTES: 1. The ChloroMatic guarantee does not apply to commercial or semi-commercial installations, i.e. where the system runs more than an average of 8 hours per day over the year. Guarantee on commercial and semi-commercial installations is 12 months only on both power supply and cells. 2.
  • Page 16 SIMPLE DESCRIPTION OF OPERATION The pH control has been designed to provide an acid feed in proportion to the difference between the actual pH and the pH set point. The control also operates on a cycle to allow the acid being fed to mix with the pool water. The cycle is approximately five minutes duration. If the pH is 0.3pH or more above the set pH at the start of a cycle the acid dosing pump will operate continuously until the pH falls below the set point plus 0.3pH.
  • Page 17 4 New tube is inserted into the pump in reverse of removal procedure. For further information on the operation and maintenance of the Davey Peristaltic Pump, please refer to the Peristaltic Pump Installation & Operating Instructions included with your ChloroMatic ®...
  • Page 18 Notes & Service History:...
  • Page 20 Davey Dealer from which you purchased the Davey product. Alternatively you can phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or send a written letter to Davey at the address listed below.