Function List - Mitsubishi Electric AT-50A Instruction Book

Air-conditioner control system advanced touch controller
Hide thumbs Also See for AT-50A:
Table of Contents

Function List

The table below summarizes the functions that are available on the AT-50A.
Refer to the pages listed for details.
Function
Switches the ON/OFF operation of the units such as air conditioning
ON/OFF Operation
units. The LED on the Collective ON/OFF button will light up when one
or more units are in operation and off when all units are stopped.
Switches the mode "Cooling/Dry/Fan/Auto/Heating" for each group or all
Mode
*1
groups. (Switches the mode "Bypass/Heat recovery/ Auto" for LOSSNAY
groups.)
Set Temperature
*1
Sets the set temperature for each group or all groups.
Fan Speed
*1
Adjusts the fan speed for each group or all groups.
Air Direction
*1
Adjusts the air direction for each group or all groups.
*1
Unit Operation
Louver
Enables/disables the louver for each group or all groups.
The ON/OFF operation of the interlocked ventilation unit is interlocked
ON/OFF Operation
with the ON/OFF operation of the air conditioning unit. The interlocked
for Interlocked
ventilation units can be independently operated for ON (High/Low)/ OFF
*1
for each group or all groups. (When the ventilation unit is interlocked
Ventilation
with the air conditioning unit, the ventilation mode cannot be used.)
The following functions can be collectively executed on multiple groups:
Collective Operation
Setback, Schedule, Mode, Temperature Correction, RC Prohibition.
Sets the date, time, and display formats. The current time will appear at
Date and Time
the top right corner of the HOME screen.
• Allows the user to set the Weekly schedule for each group.
• Maximum of 16 events can be scheduled for each day.
• The types of actions that can be scheduled are as follows: ON/OFF,
Mode, Set Temperature, Fan Speed, Air Direction, and Remote
Weekly/1-day
Controller Operation Prohibition.
schedule
• Maximum of 12 patterns can be configured for the Weekly schedule,
Time and
and 5 for 1-day schedule.
Schedule
• Two types of weekly schedule (Summer/Winter) can be set.
• 1-day schedule overrides the Weekly schedule.
This function helps keep the indoor temperature in the
Setback Control
temperature range while the units are stopped and during the
time this function is effective.
Disabling scheduled
Scheduled operation can be temporarily disabled.
This setting must be set to OFF to run scheduled operation.
operation
Automatically switches the entire system (all indoor units that are
connected to the same outdoor units) to Cooling or Heating by
periodically monitoring the room temperature and the preset temperature
System
System-Changeover
of each group and determining the best operation mode.
Management
• The System-Changeover function is not available for the following
types of products: Simultaneous Cooling/Heating units (with automatic
mode change function), Mr. SLIM®, LOSSNAY, and DIDO controller.
*1: Available functions vary depending on the unit type. Only the functions that are supported by the connected units can
be controlled from the AT-50A.
4
Description
Page
18
18
20
21
21
21
21
19
38
27
27
35
22
59
Function
Locks the following buttons: Collective ON/OFF, F1, F2, and Main
Menu.
Lock Buttons
Locks the following functions: ON/OFF, Mode, Set Temp, Fan
Speed, and Schedule ON/OFF.
Set Temperature
Limits the available temperature range for the local remote
Range Limit
controllers (each group or all groups).
Locks the following buttons on the local remote controllers: ON/
Prohibit Remote
Restriction
OFF, Mode, Set Temperature, and Filter Reset buttons (collectively
Controller
Settings
or by group)
When set as the main controller, operation of the following modes
with the local remote controllers can be prohibited.
When cooling is prohibited: Cooling, dry, automatic cannot be
Operation Mode
chosen.
Selection Limit
When heating is prohibited: Heating, automatic cannot be chosen.
When cooling/heating is prohibited: Cooling, dry, heating, automatic
cannot be chosen.
Selects the display formats for the following items: Display
language, temperature unit, room temperature, display or non-
Display Format
display of Cooling/Heating mode icons (during Auto mode),
backlight timer, and group names.
The F1 button and the F2 button can be set as a run button of the
following collective operation: Setback, Schedule, Operation Mode,
Function Key Setting
Temperature Correction, Remote Controller Prohibition.
When the Group icon is touched, the action differs depending on
the operation mode. Default is set to the operation mode 2.
Operation mode 1: Turns ON/OFF the units in the group whose
Basic Settings
Operation mode 2: Displays the check mark when Group icon is
HOME screen
Operation Mode
Setting
Operation mode 3: Directly moves to the Group screen of the
Volume Control
Sets the sound volume and screen brightness.
If an error occurs on the AT-50A controller or the units and
controllers it controls, the LED on the Collective ON/OFF button
Error
will blink. If an error occurs on the indoor or LOSSNAY units,
appear on the corresponding group icon on the HOME screen. The
error code can be verified and reset on the Status List screen.
Filter Icon will appear on the HOME screen when the filter is due
Maintenance
Filter sign
for cleaning. The icon can be removed from the Status List screen.
Touch Panel
Disables the touch panel to allow the user to clean the panel.
Cleaning Mode
Touch Panel
Calibrates the touch panel if the touch panel does not respond
Calibration Mode
correctly when touched.
Receives input signals from external devices and start/stop all
External input
groups of units or permit/prohibit operations from the local remote
controllers. Requires cable connections.
Miscellaneous
Outputs the operation status of the units (ON/OFF) or error signals
External output
to external devices collectively, using contact signals. Requires
cable connections.
Description
Page
Group icon is touched.
touched. Touch the Group icons of the groups
to be operated, and then touch the "OPERATE"
button to move to the Group screen. Multiple
groups can be selected. Use this mode when
operating the multiple groups collectively.
group whose Group icon is touched.
will
11
23
42
44
46
48
50
54
41
55
57
57
61
56
5

Hide quick links:

Table of Contents
loading

Table of Contents