GE MDS Master Station Installation Instructions Manual
GE MDS Master Station Installation Instructions Manual

GE MDS Master Station Installation Instructions Manual

Hide thumbs Also See for MDS Master Station:

Quick Links

1.0 INTRODUCTION
The MDS Master Station serves as a central station in a multiple ad-
dress system (MAS) wireless network. It provides long range, duplex (or
simplex) communication between a control point and associated re-
motes. It is fully redundant for mission-critical applications, and is a
compatible replacement for older MDS x790 Master Stations.
The MDS Master Station works with a wide array of wireless equipment,
including MDS SD Transceivers, legacy MDS x710 radios, and addi-
tional wireless options, depending on the modules installed in the
chassis.
Figure 1: MDS Master Station
All modules are installed on slide-in assemblies, accessible from the
front of the unit. A protective cover on the unit's face slides off, allowing
access to the modules and all interface connectors. In addition to
communication modules, up to two power supply units may be installed
and are available to suit a wide range of AC and DC power require-
ments.
Each module is secured to the chassis with knurled fasteners for easy
changes, when required. Figure 2 shows a common configuration of
installed modules.
Platform Manager
Supply 1 (DC)
Supply 2 (AC)
Figure 2: Front Panel Connectors & Indicators
(Front cover removed)
Master Station modules are factory installed and cabled.
Module Descriptions - Redundant Station
installed in a redundant configuration, from left to right. For a
non-redundant configuration, blank plates are used in place of the
redundant power supply and radio modules and a non-redundant ver-
sion of the Alarm/Relay module is installed.
The MDS Master Station supports Ethernet or serial polling depending
on order options. A host computer may be connected to the appropriate
port on the chassis (LAN for Ethernet; COM1/2 for serial signaling).
Configuration of the unit is performed through a web interface. This
requires a LAN connection to one of the Ethernet ports on the Platform
Manager module. Configuration options are similar to those of the SD
Transceiver and the radio supports full SD functionality in transparent
mode. In addition, a command line interface (CLI) is available through
the mini USB port using the proper USB drivers available at
www.gemds.com.
05-6398A01, Rev. C
Radio A
Radio B
Alarm/Relay
Duplexer
Table 1:
describes each module
MDS Master Station Setup Guide
MDS Master Station
Table 1: Module Descriptions - Redundant Station
Module
ID
Power Supply 1,
Varies
Power Supply 2
Platform Manager
6834
Radio A,
6846
(SDM9)
Radio B
6847
Alarm/Relay
6848
Duplexer
6837
1.1
Related Documentation
In addition to this setup guide, the MDS Master Station Technical
Manual (05-6399A01, under development) provides guidance on sys-
tem design, advanced configuration, and maintenance. The Technical
Manual is available to personnel involved in the design, commissioning
and maintenance of the network. Electronic copies of the latest user
documents and support files are available free of charge at
www.gemds.com.
1.2
Options and Accessories
The MDS Master Station may be equipped with optional battery backup
(10-watt RF power output - 5 watt is standard) and a variety of duplexer
and module options. Contact your factory representative for information
on any of these options.
In addition, GE MDS offers an Accessories Selection Guide listing
additional items that may be used with many of our products. Contact
your factory representative or visit www.gemds.com for the latest copy.
1.3
Typical Application
Figure 3: Application Example
common arrangement of the MDS Master Station as used in a multiple
address radio network. The system shows both SD and legacy x710
remote transceivers in use.
Depending on order options, the MDS Master Station can communicate
with remotes employing Ethernet signaling, serial signaling, or a mix of
both.
Setup Guide
Function
Input power supply. In a redundant
configuration, both supplies work in
tandem and are independent of which
radio is active.
Provides management and data interface
functions.
Single or redundant full duplex SD Master
radios.
Redundant—Active radio relay and
alarm/audio interface.
Non-redundant—Alarm and audio
interface.
Internal RF duplexer (if equipped)
on the following page shows a
1
loading

Summary of Contents for GE MDS Master Station

  • Page 1 MDS Master Station Setup Guide 1.0 INTRODUCTION Table 1: Module Descriptions - Redundant Station The MDS Master Station serves as a central station in a multiple ad- dress system (MAS) wireless network. It provides long range, duplex (or Module Function simplex) communication between a control point and associated re- motes.
  • Page 2: Installation

    Ethernet cable may be used in combination with nectors. a DB9-F to RJ-45 connector (GE MDS part no. 73-2434A12). • Ethernet LAN—Attach data equipment to the ETH1 and/or When rack mounting, the rack ears can be installed in one of three ETH2 port.
  • Page 3: Software Configuration

    Configuration via Web Device Manager The configuration PC may be connected to the unit by USB or Ethernet. The following steps describe a configuration using the GE MDS Device Manager running on the unit. The Device Manager is accessible through ETH1 or ETH2 using a web browser.
  • Page 4 Radio, Security, or Maintenance and Status... 4.0 IN-SERVICE OPERATION In-service operation of the MDS Master Station is completely automatic. The only operator actions required are to apply power and check the module LEDs for proper indications as shown.
  • Page 5 Device Manger UI. RTS (Request to Send) Technical Assistance Factory technical assistance is available by contacting GE MDS during Table 6: COM2 Pin-out - Default Console Port business hours (8:30 AM to 6:00 PM Eastern Time). For telephone assistance, call (585) 241-5510, or visit our website at www.gemds.com...
  • Page 6 If you have additional questions or need an exact specification for a product, please contact GE MDS, using the information at the back of this guide. In addition, manual updates can be found on our web site at www.gemds.com.